wayground logo

Free Printable Worksheets

Font size

S
M
L
XL
Worksheets

EPA Core Quiz

Total questions: 20

Worksheet time: 7mins

Name
Class
Date
1.

Chlorofluorocarbon refrigerants have the highest

ozone depletion potential and are the most

harmful to stratospheric ozone.

a)

True

b)

False

2.

What does ODP stand for?

a)

outdoor pollutants

b)

ozone depletion potential

c)

ozone distillation process

3.

A refrigerant recovery cylinder should be filled to no more than

a)

85%

b)

45%

c)

90%

d)

80%

4.

What is ODP?

a)

The measure of the density of the stratosphere

b)

the measurement of the ozone layer

c)

the measurement of CFC's and HCFC's ability to destroy the ozone

5.

Which refrigerant is the most harmful to the ozone layer

a)

R-12 CFC

b)

R-22 HCFC

c)

R-134A HFC

6.

The clean air act

a)

prohibits venting of CFC,s and HCFS,s as of November 15, 1995

b)

prohibits venting of CFC,s and HCFC,s as of july 1,1994

c)

prohibits venting of CFC's and HCFC's as of November 14,1994

7.

Zeotropic and some near-azeotropic blends use

a)

Bubble and dew points

b)

R-400

c)

R-407c

d)

Bubble points

8.

When disposing of a refrigerant cylinder,

a)

vent the refrigerant to the atmosphere and remove the top.

b)

recover the refrigerant and reader the cylinder useless.

c)

evacuate the cylinder and use as an air tank.

9.

When is it mostly likely that an appliances will need its refrigerant recovered?

a)

before it can be discarded

b)

after purging the system with dry nitrogen

c)

after the system obtained a leak

10.

What is known as de minimis release?

a)

It is a maximum amount of refrigerant that should not be released to atmosphere when servicing equipment

b)

It is a minimum amount of refrigerant that can be released to the atmosphere when servicing equipment

c)

It is a minimum amount of refrigerant that must be recovered when servicing equipment

11.

What does the term temperature glide refer to?

a)

the different refrigerant boiling and condensing points of a blended refrigerant

b)

zeotropic refrigerant as it is charged into a system as a gas

c)

the point at which the refrigerant temperature decreases at it exits an excessive valve

12.

Service technicians who violate the Clean Air Act

a)

may be fined

b)

may lose certification

c)

Both A and B

13.

Azeotropic refrigerant mixtures contain

a)

One refrigerant

b)

No refrigerants

c)

Two or more refrigerants

d)

Three or more refrigerants

14.

How much of a fine can be issued for venting refrigerant

a)

$5,000

b)

$10,000

c)

$27,500

15.

Leak detection methods and devices used must be approved by the

a)

manufacturer

b)

employer

c)

co-worker

d)

manager

16.

An award of _____ is given to the person who supplies information about the venting of refrigerants.

a)

$5,000

b)

$10,000

c)

$27,500

17.

Fractionation is the separation of blended refrigerants caused by different vapor pressures.

a)

True

b)

False

18.

What is the pressure range of the high side gauge that is located on a manifold set?

a)

30" Hg to 300 psig.

b)

0 psig to 300 psig

c)

0 psig to 500 psig

19.

Hydrochlorofluorocarbon (HCFC) refrigerants contain

a)

hydrogen, chlorine, fluorine, and carbon

b)

bromine, zinc, gold, and copper

c)

scandium, calcium, hydrogen, and iron

d)

hydrogen, oxygen, carbon, fluorine

20.

Ozone in the stratosphere consists of

molecules containing 3

a)

oxygen atoms

b)

nitrogen atoms

c)

carbon atoms

d)

hydrogen atoms