ACR-201 FINAL

Total questions: 78

Worksheet time: 39mins

Name
Class
Date
1.

ASHRAE Standard         , “Ventilation for Acceptable Indoor Air Quality,” is the standard generally used to determine acceptable indoor air quality.

a)

55

b)

15

c)

90

d)

62

2.

An electrostatic precipitator is the same as

a)

an extended surface air filter.

b)

a fiberglass media filter.

c)

an electronic air cleaner.

d)

a washable steel air filter.

3.

A colorless, odorless, radioactive gas that can cause lung cancer is:

a)

Smog

b)

Carbon Monoxide

c)

Methane

d)

Radon

4.

The purifier ingredient in an activated charcoal air purifier may be

a)

activated carbon.

b)

coconut shell pellets.

c)

manufactured from coal.

d)

any of the above.

5.

Examples of biological contaminants are:

a)

Mold and mildew

b)

Viruses

c)

Dust mites

d)

All the above

6.

Ion generators ________ particles in an area.

a)

disintegrate

b)

charge

c)

wash

d)

remove odors from

7.

Methods for controlling indoor air contaminants include eliminating the source of contamination, providing adequate ventilation, and adding odorants to eliminate foul smells.

a)

True

b)

False

8.

The relative humidity in heated homes is generally the ________ in the winter season.

a)

highest

b)

lowest

9.

General types of air cleaners include ultraviolet-C light and ion generators as well as:

a)

Volatile filters and mechanical filters

b)

Outdoor filters and indoor filters

c)

Mechanical filters and electronic air cleaners

d)

Electronic air cleaners and humidifiers

10.

The recommended relative humidity for a home is between

a)

50% and 70%.

b)

20% and 40%.

c)

30% and 50%

d)

40% and 60%.

11.

Static electricity is more commonly a problem when the air is ________.

a)

dry

b)

moist

12.

The plenum-mounted humidifier is installed in the ________ plenum.

a)

supply

b)

return

c)

supply or return

13.

True or False: Carbon monoxide is produced by mixing vapors from nitrogen dioxide and sulfur dioxide.

a)

True

b)

False

14.

Fiberglass filter media is generally coated with a special nondrying, nontoxic adhesive on each fiber.

a)

True

b)

False

15.

Some humidifiers have their own water-heating devices.

a)

True

b)

False

16.

When the relative humidity goes above 60%, ___________.

a)

nasal and throat passages dry out

b)

static electricity in the air can cause small electric shocks

c)

bacteria, viruses, fungi and other organisms become more active

d)

furniture joints and floors may loosen and creak

17.

___________ is the process of supplying air by natural or mechanical means to a space.

a)

infiltration

b)

ventilation

c)

decontamination

d)

filtration

18.

A fiber found in older pipe and furnace insulation materials, shingles, textured paints, and floor tiles that is dangerous and may cause lung cancer is ________.

a)

asbestos

b)

lead

c)

formaldehyde

d)

pesticides

19.

________ is a fungus that releases it spores, which can be harmful to humans, into the air and is usually found in areas of high humidity.

a)

Mold

b)

Radon

c)

Dust Mites

d)

Asbestos

20.

Sick building syndrome is a term given to situations when people who spend considerable time in a particular building experience health problems.

a)

True

b)

False

21.

A poisonous, lighter-than-air, colorless, odorless gas that is produced by incomplete combustion is ________.

a)

methane

b)

carbon dioxide (CO2)

c)

nvironmental tobacco smoke (ETS)

d)

carbon monoxide (CO)

22.

Pollutants released from combustion appliances include nitrogen dioxide and sulfur dioxide.

a)

True

b)

False

23.

A type of filter that is capable of capturing particles as small as .3 microns is a ________.

a)

pleated filter

b)

pocket filter

c)

cube filter

d)

HEPA filter

24.

The term used to express the amount of moisture in the air compared to the amount of moisture it can hold at a specific temperature is called __________.

a)

relative humidity

b)

absolute humidity

c)

water vapor

d)

latent heat

25.

Two types of atomizing humidifiers are the spray-nozzle and the evaporative.

a)

True

b)

False

26.

The propeller-type fan is most often used as a(n) ___________.

a)

centrifugal blower

b)

exhaust fan or a condenser fan

c)

blower motor in a residential gas furnace

d)

all of the above

27.

The two types of drive assemblies that are commonly used to turn fans and blowers are __________.

a)

rotary drive and scroll drive

b)

direct drive and rotary drive

c)

belt drive and direct drive

d)

screw drive and rotary drive

28.

A(n) ________ is recommended on all installations to prevent noise transmission through the duct system.

a)

vibration eliminator

b)

electronically commutated motor (ECM)

c)

direct-drive blower assembly

d)

fiberglass plenum

29.

The return duct system distributes air to the terminal units, registers, grilles, or diffusers in the conditioned space.

a)

True

b)

False

30.

Plenum, extended plenum, reducing plenum, or perimeter loop are all types of ________.

a)

ventilation methods

b)

duct materials

c)

duct systems

d)

air balancing methods

31.

A __________ is used to make a duct more rigid, which prevents it from swelling and making noises when the blower starts and stops.

a)

cross-break

b)

takeoff fitting

c)

balancing damper

d)

vibration eliminator

32.

Flexible round duct comes in sizes up to about 24 inches in diameter and 25 feet of length to a box.

a)

True

b)

False

33.

A branch duct should be fastened to the main trunk line with a __________.

a)

flex connector

b)

boot

c)

takeoff fitting

d)

end cap

34.

________ is a very thick, putty-like substance that is applied to the duct connections to help make the system airtight.

a)

Foil tape

b)

Duct insulation

c)

Double-sided tape

d)

Mastic

35.

Two ways that fresh air can enter a structure are infiltration and ventilation.

a)

True

b)

False

36.

Which of the following types of fan is used to move large amounts of air against a low static pressure drop?

a)

Vane axial

b)

Centrifugal

c)

Large

d)

Propeller

37.

The three pressures created by air moving through a duct system are:

a)

Static pressure, atmospheric pressure, and total pressure

b)

Static pressure, friction pressure, and total pressure

c)

Velocity pressure, static pressure, and atmospheric pressure

d)

Velocity pressure, static pressure, and total pressure

38.

Pressure in ductwork is expressed in which of the following?

a)

Inches of water column

b)

Psig

c)

Psia

d)

Inches of Hg

39.

Warm air heats a room better if distributed

a)

low in the room.

b)

high in the room.

c)

behind the furniture.

d)

under the curtains.

40.

Multiple-zone systems often use oversized ducts or a damper to alleviate the problem of excess air when only some zones are calling for conditioning.

a)

True

b)

False

41.

The duct sizes on the air friction chart are expressed in which of the following?

a)

Square

b)

Round

c)

Oval

d)

Rectangular

42.

Turbulence in airflow causes friction drop.

a)

True

b)

False

43.

True or False: Air for cooling circulates better through the conditioned space when it is introduced to the space through floor registers.

a)

True

b)

False

44.

When connecting round metal duct sections, a minimum of ____ self-taping sheet metal screws should be used.

a)

5

b)

4

c)

3

d)

2

45.

The applied voltage (the voltage that the unit will actually be drawing) should be within ____% of the rated voltage of the unit.

a)

3

b)

5

c)

10

d)

7

46.

A disconnect or shutoff switch should be installed within _____ feet of each unit and within sight of the unit.

a)

15

b)

25

c)

10

d)

20

47.

18-4 low-voltage wire is _________.

a)

18-gauge wire with 4 conductors inside

b)

14-gauge wire with a current rating of 4 amps

c)

18-gauge wire, 4 total allowed in ½ inch conduit

d)

4-gauge wire with a current rating of 18 amps

48.

An air conditioner in a climate with average humidity will collect about 3 pints of condensate per hour of operation for each ton of air-conditioning.

a)

True

b)

False

49.

A ________ is located in an auxiliary drain pan and is wired in series with the low voltage power supply.

a)

float switch

b)

pressure switch

c)

delay timer

d)

auxiliary thermostat

50.

Line sets come in standard lengths of ________.

a)

15 feet and 35 feet

b)

25 feet and 50 feet

c)

10 feet and 15 feet

d)

50 feet and 100 feet

51.

Split-system equipment includes all components in one cabinet or housing.

a)

True

b)

False

52.

The _____ is the fitting that connects the duct to the supply register.

a)

starting collar

b)

plenum

c)

takeoff

d)

boot

53.

Round metal duct requires more clearance space than square or rectangular duct.

a)

True

b)

False

54.

The three crafts normally associated with an air-conditioning installation are:

a)

Plumbing, programming, and electrical

b)

Electrical, sheet metal, and programming

c)

Sheet metal, electrical, and mechanical

d)

Sheet metal, plumbing, and carpentry

55.

When insulation on the inside of the duct comes loose it causes

a)

the system to shut off.

b)

high head pressure.

c)

increased airflow.

d)

reduced airflow.

56.

True or False: The flexible duct system is the most economical.

a)

True

b)

False

57.

Most duct insulation is made of         .

a)

fiberglass

b)

rubber

c)

PVC

d)

foam

58.

Insulation on duct does not prevent duct from sweating.

a)

True

b)

False

59.

The two different duct configurations for package units are under and over and side by side.

a)

True

b)

False

60.

True or False: A package unit comes from the factory with the charge inside.

a)

True

b)

False

61.

The most popular method for determining the heat gain and heat loss of a residential structure is to use _________.

a)

the square footage of the structure

b)

a Manual J calculation

c)

the geographical location of the structure

d)

the Department of Energy's climate regions

62.

Oversized air-conditioning equipment will cool the space faster, resulting in ________.

a)

higher efficiency

b)

poor dehumidification

c)

poor drainage

d)

greater dehumidification

63.

To determine the temperature differential for cooling equipment (Cooling Design TD), use the formula _____________.

a)

average outdoor ambient temperature – 75°F (standard)

b)

indoor design temperature – outdoor design temperature

c)

75°F(standard) – indoor design temperature

d)

outdoor design temperature – indoor design temperature

64.

As an insulating material is compressed, its R-value will ___________.

a)

multiply by the area that is compressed

b)

go down

c)

remain unchanged

d)

go up

65.

The U-value of a material describes its thermal resistance and the R-value of a material describes its thermal conductivity.

a)

True

b)

False

66.

_______ make up a large portion of the structural envelope and account for a large percentage of the total heat loss of a structure.

a)

Walls

b)

Floors

c)

Windows

d)

Cracks and openings

67.

In general, the rate of heat transfer through a wall can be determined by _________.

a)

U-Vale + TD + Area

b)

R-value × TD × Area

c)

U-value × TD × Area

d)

U-value ÷ TD × Area

68.

A term that is used to describe the area of a wall before any doors or windows are cut into it is __________.

a)

gross wall area

b)

net wall area

c)

door area

d)

window area

69.

The higher the U-value, the easier it is for heat to pass through the material.

a)

True

b)

False

70.

The two important factors that affect the U-value for the below-grade portion of a wall are ___________.

a)

how far below grade the wall is and whether it is an interior or exterior wall

b)

whether it is an interior or exterior wall and the construction material

c)

how far below grade the wall is and the construction material

d)

the number of windows and the number of doors in the wall

71.

An oversized air-conditioning system will

a)

cost more to install and operate.

b)

be more efficient than an undersized air-conditioning system.

c)

be better able to maintain the desired humidity in the conditioned space.

d)

require a smaller air distribution system than an undersized air-conditioning system.

72.

An exterior wall

a)

separates a conditioned interior space from an unconditioned interior space.

b)

separates an interior conditioned space from the outside.

c)

separates one interior conditioned space from another conditioned interior space.

d)

separates an interior unconditioned space from the outside.

73.

A partition wall

a)

separates a conditioned interior space from an unconditioned interior space.

b)

separates an interior conditioned space from the outside.

c)

separates one interior conditioned space from another conditioned interior space.

d)

separates an interior unconditioned space from the outside.

74.

As the temperature differential across a panel increases,

a)

the rate of heat transfer through the panel will increase.

b)

the rate of heat transfer through the panel will decrease.

c)

the rate of heat transfer through the panel will remain unchanged since the temperature

d)

difference does not affect the rate of heat transfer.

75.

The typical indoor design temperature used for heat gain calculations is

a)

65°F.

b)

70°F.

c)

75°F.

d)

80°F.

76.

The typical indoor design temperature used for heat loss calculations is

a)

65°F.

b)

70°F.

c)

75°F.

d)

80°F.

77.

All of the following are taken into account on a heat loss calculation except

a)

exterior walls.

b)

interior walls.

c)

basement floors.

d)

top-floor ceilings.

78.

All of the following are taken into account on a heat gain calculation except

a)

exterior walls.

b)

partition walls.

c)

basement floors.

d)

top-floor ceilings.