1.

What is the minimum ceiling height for a habitable room in the Philippines as per the NBCP?

a)

2.0 m

b)

2.4m

c)

2.7 m

d)

3.0 m

2.

What is the standard width for a fire exit corridor in commercial buildings?

a)

0.90 m

b)

1.20 m

c)

1.50 m

d)

1.80 m

3.

What is the required minimum width for stairways in residential buildings?

a)

0.75 m

b)

0.90 m

c)

1.00 m

d)

1.20 m

4.

What is the minimum width for a public hallway in schools?

a)

1.5 m

b)

1.8 m

c)

2.0 m

d)

2.4 m

5.

For high-rise buildings, which system is mandated for vertical transportation?

a)

Elevators

b)

Escalators

c)

Stairwells

d)

Conveyor belts

6.

Which code governs the design of fire exits in buildings?

a)

NSCP

b)

NBCP

c)

Fire Code of the Philippines

d)

Both b and c

7.

What is the minimum window opening size for a habitable room as per the National Building Code of the Philippines (NBCP)?

a)

5% of the floor area

b)

10% of the floor area

c)

12% of the floor area

d)

15% of the floor area

8.

Which type of building requires at least 1/10th of the floor area as windows for natural lighting?

a)

Warehouses

b)

Commercial buildings

c)

Residential Buildings

d)

Industrial Buildings

9.

What is the minimum floor area for a single-occupancy residential unit?

a)

6 sqm

b)

10 sqm

c)

12 sqm

d)

15 sqm

10.

What percentage of a room's floor area should be allocated for window openings for proper natural ventilation?

a)

5%

b)

10%

c)

15%

d)

20%

11.

In schools, what is the minimum classroom size for elementary and high schools?

a)

5 m x 6m

b)

7 m x 7m

c)

7 m x 8m

d)

7m x 9m

12.

What is the required parking space size for standard vehicles?

a)

2.0 m x 4.0 m

b)

2.4 m x 5.0 m

c)

3.0 m x 6.0 m

d)

3.6 m x 6.0 m

13.

What is the importance of wind load in structural design?

a)

To calculate weight-bearing capacity

b)

To ensure seismic resistance

c)

To account for lateral forces on the building

d)

To determine fire resistance

14.

What is the minimum required thickness for exterior walls in high-rise buildings?

a)

100 mm

b)

150 mm

c)

200 mm

d)

250 mm

15.

For bathrooms, the minimum window opening requirement is:

a)

1/10th of the floor area

b)

1/12th of the floor area

c)

1/20th of the floor area

d)

1/30th of the floor area

16.

What is the required front setback for a residential building on an interior lot?

a)

1 meter

b)

2 meters

c)

3 meters

d)

5 meters

17.

What is the required setback from the rear property line for residential buildings?

a)

1 meters

b)

2 meters

c)

3 meters

d)

5 meters