wayground logo

Free Printable Worksheets

NEW

Font size

S
M
L
XL
Worksheets

Block 14

Total questions: 54

Worksheet time: 27mins

Name
Class
Date
1.

The NGH provides heated air for what 5 things

a)

Aircraft cabins, maintenance equipment, passenger areas, storage facilities, and portable offices

b)

Aircraft Maintenance Personnel, flight line support, ground vehicles, maintenance shelters and portable hangars

c)

Ground crews, aircraft systems testing, repair stations, emergency shelters, and field operations

d)

Runway de-icing, aviation tools, hangar heating, fuel trucks, and aircraft service areas

2.

The NGH is a ___

a)

Fully Enclosed, self contained unit

b)

Portable, high-capacity cooling system

c)

Compact, trailer-mounted heating device

d)

Modular, multi-purpose heating unit

3.

The NGH is unsafe for operation in ____ environments due to open flames in the ____

a)

Explosive & Combustion Chamber

b)

Flammable & Heating Element

c)

Hazardous & Burner Assembly

d)

Volatile & Ignition System

4.

Internal components are located where?

a)

Burner Tube

b)

Burner Motor

c)

Combustion Tube

d)

Fuel Burner unit

5.

What are the 3 internal components

a)

Fuel Nozzle, Ignition Points, Photocell

b)

Burner Tube, Photocell, Fuel Nozzel

c)

Ignition Points, Burner Motor, Ignition Transformer

d)

Blower, Fan, Heater

6.

____ Atomizes fuel into a mist that mixes with air as it enters the combustion chamber

a)

Photocell

b)

Fuel Nozzel

c)

Combustion Air Blower

d)

Burner Motor

7.

What are the 4 external components

a)

Fuel Nozzle, Ignition Points, Photocell, Burner Tube

b)

Burner Tube, Photocell, Fuel Nozzel, Ignition Transformer

c)

Ignition Transformer, Burner Motor, Combustion Air Blower, High Pressure Fuel Injection Pump

d)

Blower, Fan, Heater, High Pressure Fuel Injection Pump

8.

A heat range of ____ is provided by the three temperature settings

a)

225 - 508°F

b)

75 - 230°F

c)

405 - 670°F

d)

150 - 305°F

9.

___ Fan that provides all air for combustion in the combustion chamber

a)

Flammable Air Blower

b)

Combustion Air Blower

c)

High Pressure Fuel Injector Pump

d)

Burner Motor

10.

___ Operated by burner motor, provides fuel flow for burner operation at 175 psi

a)

Flammable Air Blower

b)

Combustion Air Blower

c)

High Pressure Fuel Injector Pump

d)

Burner Motor

11.

The Fuel Pressure Injection Pump operates at what psi

a)

125

b)

175

c)

95

d)

205

12.

The diesel engine drives what?

a)

Burner Motor

b)

Alternator/Generator

c)

Air Engine

d)

Engine/Burner

13.

What is the low temperature setting for the NGH

a)

150 - 185°F

b)

210 - 245°F

c)

270 - 305°F

d)

70 - 105°F

14.

What is the medium temperature setting for the NGH

a)

150 - 185°F

b)

210 - 245°F

c)

270 - 305°F

d)

70 - 105°F

15.

What is the high temperature setting for the NGH

a)

150 - 185°F

b)

210 - 245°F

c)

270 - 305°F

d)

70 - 105°F

16.

___ Steps up 120 VAC to 14,000 VAC for ignition arc

a)

Ignition Transformer

b)

Burner Motor

c)

Ignition Points

d)

Photocell

17.

____ provides rotational motion for combustion air blower and fuel injection pump

a)

Ignition Transformer

b)

Burner Motor

c)

Ignition Points

d)

Photocell

18.

Burner Motor operates at ____ rpm

a)

3450

b)

120

c)

14,000

d)

3050

19.

Ignition transformer steps up 120VAC to ____

a)

14,000 VDC

b)

3,450 VAC

c)

14,000 VAC

d)

3,450 VDC

20.

____ Provides the air gap for the arc to ignite the air/fuel mixture in the combustion chamber

a)

Ignition Transformer

b)

Burner Motor

c)

Ignition Points

d)

Photocell

21.

___ Monitors presence of a flame (light) in the combustion chamber

a)

Ignition Transformer

b)

Burner Motor

c)

Ignition Points

d)

Photocell

22.

____ Provides a suitable atmosphere for complete combustion of air/fuel mixture

a)

Combustion Chamber

b)

Heat Exchanger

c)

Baffles

d)

Combustion Air Blower

23.

____ Houses the fuel burner unit's burner tube in its inlet

a)

Combustion Chamber

b)

Heat Exchanger

c)

Baffles

d)

Combustion Air Blower

24.

____ Ensures a clean combustion with virtually no coking (carbon buildup resulting from incomplete burning of fuel)

a)

Combustion Chamber

b)

Heat Exchanger

c)

Baffles

d)

Combustion Air Blower

25.

Combustion gases leave and are routed through the heat exchangers ____

a)

Ports

b)

Channels

c)

Baffles

d)

Tubes

26.

what Provides passages for main air flow (clean air) through the heat exchanger

a)

Ports

b)

Channels

c)

Baffles

d)

Tubes

27.

____ Separates main air flow from combustion gases keeping carbon monoxide out of the main airflow

a)

Combustion Chamber

b)

Heat Exchanger

c)

Baffles

d)

Combustion Air Blower

28.

____ is a Stainless steel box made of hollow ports and channels

a)

Combustion Chamber

b)

Heat Exchanger

c)

Baffles

d)

Combustion Air Blower

29.

____ Reduces the velocity of the combustion gases to provide better heat transfer

a)

Combustion Chamber

b)

Heat Exchanger

c)

Baffles

d)

Combustion Air Blower

30.

Where are baffles located

a)

Combustion Air Blower

b)

Heat Exchanger Channels

c)

Main Air Fan

d)

Exhaust Pipe

31.

The heat exchanger works on the principles of?

a)

Thermal induction

b)

Heat transfer

c)

Heat induction

d)

Thermal transfer

32.

Thermal energy is transferred from the ____ to the main airflow through the walls of the heat exchanger

a)

Burner Motor

b)

Exhaust pipe

c)

hot combustion gases

d)

Photocell

33.

____ Provides constant air flow through the combustion chamber

a)

Combustion Air Blower

b)

Main Air Fan

c)

Exhaust System

d)

Flexible Ducts

34.

____ Provides air for combustion and forces the hot expanding gases into the heat exchanger channels and out the exhaust stack

a)

Combustion Air Blower

b)

Main Air Fan

c)

Exhaust System

d)

Flexible Ducts

35.

Uninterrupted airflow ensures _____ from the combustion chamber

a)

residual fuel is purged

b)

efficient heat transfer occurs

c)

proper pressure is maintained

d)

harmful gases are expelled

36.

The combustion air blower is driven by the?

a)

Alternator/Generator

b)

Burner Motor

c)

Main Air Fan

d)

Fuel Pumps

37.

Main air fan is Directly driven by a ____ electric AC motor

a)

3550 rpm

b)

1350 rpm

c)

1700 rpm

d)

1200 rpm

38.

____ Provides the main airflow to be heated or used for ventilation

a)

Combustion Air Blower

b)

Main Air Fan

c)

Exhaust System

d)

Flexible Ducts

39.

Main air is forced around the burner chamber and through the heat exchanger ports by the ____

a)

Combustion Air Blower

b)

Main Air Fan

c)

Exhaust System

d)

Flexible Ducts

40.

____ Carries heated/ventilated air to the required area

a)

Combustion Air Blower

b)

Main Air Fan

c)

Exhaust System

d)

Flexible Ducts

41.

Operated inside a building, exhaust gases must be routed outside by means of a suitable ____

a)

Combustion Air Blower

b)

Main Air Fan

c)

Exhaust System

d)

Flexible Ducts

42.

What are the 2 exhaust system outlets

a)

Burner Assembly Exhaust & Ventilation Exhaust

b)

Power Unit Exhaust & Auxiliary Exhaust

c)

Engine Exhaust & Heat Exchanger Exhaust

d)

Combustion Chamber Exhaust & Cooling Air Exhaust

43.

When a carbon monoxide test fails what must be replaced

a)

Exhaust System

b)

Heat Exchanger

c)

Combustion Chamber

d)

Air Deflector

44.

Where is the Air Deflector located

a)

Combustion Chamber

b)

Main Airflow Stream

c)

Exhaust System

d)

Blower Assembly

45.

____ Directs main airflow air around the combustion chamber to the heat exchanger port and outlet port

a)

Exhaust System

b)

Heat Exchanger

c)

Combustion Chamber

d)

Air Deflector

46.

Where is the Air Deflector located

a)

Combustion Chamber

b)

Main Airflow Stream

c)

Exhaust System

d)

Blower Assembly

47.

What Allows heated air to leave the unit and to attach flexible ducts

a)

Outlet Port

b)

Outlet Cover

c)

Exhaust System

d)

Air Deflector

48.

What protects the NGH from debris, water, and corrosion when not in use

a)

Outlet Port

b)

Outlet Cover

c)

Exhaust System

d)

Air Deflector

49.

When the NGH is operated inside a building a ____ must be connected to both exhaust stacks

a)

Leak proof extensions

b)

Ventilation duct

c)

Sealed exhaust pipe

d)

Heat-resistant hose

50.

The burner motor operates the ____ and ____

a)

Photocell & Burner Motor

b)

Combustion Air Blower & Fuel Injector Pump

c)

High Pressure Fuel Injector Pump & Blower Motor

d)

Burner Motor & Combustion Chamber

51.

The heat exchanger contains ports and channels to keep the ____ gasses separate from the ____ airflow.

a)

Exhaust & Clean Air

b)

Exhaust & Moisturized Air

c)

Dirty Air & Clean Air

d)

Carbon Monoxide & Chorine

52.

The heat exchanger is constructed from ___ to resist corrosion

a)

Stainless Steel

b)

Plastic

c)

Titanium

d)

Alkali metals

53.

The main airflow is provided by the

a)

Combustion Air Blower

b)

Main Air Fan

c)

Exhaust System

d)

Flexible Ducts

54.

What causes cracks

a)

Repeated Heating and Cooling

b)

Trapped Air

c)

Heated Fuel

d)

Cold Weather Conditions