Basic Maintenance Requirements of Hot Water Systems part 7

Total questions: 40

Worksheet time: 20mins

Name
Class
Date
1.

Which of the following is a basic maintenance requirement for hot water systems?

a)

Regular inspection

b)

Ignoring leaks

c)

Overloading the system

d)

Using any type of water

2.

A basic maintenance requirement for hot water systems is to regularly check for ______.

a)

leaks

b)

new installations

c)

paint quality

d)

electrical wiring

3.

Which of the following is NOT a potential cause of poor flow rate?

a)

Temperature settings on thermostat

b)

Limescale blockages

c)

Filters cleaned

d)

Pipe size too large

4.

Poor flow rate can be caused by ______.

a)

Proper lubrication of parts

b)

Limescale blockages

c)

Correct temperature settings

d)

Fully operational valves.

5.

What is one of the effects of unbalanced pressure in manually controlled showers?

a)

Increased water flow

b)

Decreased temperature

c)

Balanced pressure

d)

Increased temperature

6.

Which of the following is an indicator of maintenance required for showers? Fill in the blank: _______ settings on thermostat.

a)

Pressure

b)

Temperature

c)

Flow

d)

Volume

7.

What can cause a valve to pass water?

a)

Limescale

b)

Debris

c)

De-zincification

d)

All of the above.

8.

Fill in the blank: If an isolation valve is old or hasn’t been closed for a period of time, it may not close fully and therefore ______ water.

a)

block

b)

pass

c)

store

d)

filter

9.

What is one of the reasons leaks occur in components?

a)

Proper installation

b)

Components are insulated

c)

Components have corroded

d)

Components are new.

10.

Fill in the blank: To prevent leaks, one should ________ the compression fitting nut.

a)

Loosen

b)

Tighten

c)

Ignore

d)

Remove

11.

What causes expansion noise in hot water or central heating pipework?

a)

Cold water passing through the pipes

b)

Heated water passing through the pipes

c)

Air passing through the pipes

d)

Electrical current passing through the pipes.

12.

Fill in the blank: To address expansion noise, it is important to inspect ______.

a)

clips/brackets

b)

electrical wiring

c)

paint

d)

flooring

13.

What is the maximum velocity of water flow above which noise can become audible according to BS6700?

a)

2m/s

b)

3m/s

c)

4m/s

d)

5m/s

14.

To reduce noise when cisterns refill, collapsible silencers can be used. Another method to reduce noise is to ______.

a)

Decrease the pipe diameter

b)

Increase the pipe diameter

c)

Install a pressure reducing valve

d)

Remove the silencers

15.

What is a common complaint when the CWSC is refilling after hot water has been used?

a)

Water hammer

b)

Air lock

c)

Low pressure

d)

High pressure

16.

To address water hammer, one should inspect the FOV and ______.

a)

tap washer

b)

flow restrictor

c)

equilibrium valve

d)

clipping distances

17.

What happens if the thermostat fails open?

a)

The customer will have no hot water.

b)

The temperature will continue to rise.

c)

The water will become cold.

d)

The system will shut down.

18.

If the thermostat fails closed, the temperature will continue to ____.

a)

A) decrease

b)

B) remain constant

c)

C) rise

d)

D) fluctuate

19.

What is a possible indicator of immersion element failure?

a)

Hot water

b)

Fuse blowing

c)

Steady electricity

d)

Continuous heating

20.

In a direct cylinder, immersion element failure results in ______.

a)

Continuous hot water

b)

No hot water

c)

Occasional hot water

d)

Warm water

21.

What is a common primary heat source that could fail, resulting in no hot water?

a)

Boiler

b)

Air Conditioner

c)

Refrigerator

d)

Microwave

22.

Failure of the primary heat source could include a boiler or immersion heater, but it could also include a ________ energy source.

a)

Green

b)

Blue

c)

Red

d)

Yellow

23.

What happens if the coil fails in a heating system?

a)

The pressure from the CWSC is less than the F&E cistern.

b)

Water is forced into the primary system.

c)

The warning pipe on the F&E does not discharge.

d)

Hot water remains clear.

24.

Fill in the blank: If the coil fails, the pressure from the CWSC is slightly greater than the pressure from the ____.

a)

Primary system

b)

F&E cistern

c)

Hot water tank

d)

Overflow pipe

25.

What happens when there is a loss of air bubble in a single feed cylinder?

a)

The hot water will be discoloured when drawn off.

b)

The pressure relief valve will discharge.

c)

The system will not need draining.

d)

The air bubble will not be reinstated.

26.

In both single feed and unvented cylinders, the secondary system will need ______ to the base of the hot water cylinder.

a)

filling

b)

draining

c)

heating

d)

cooling

27.

What is a sign that water is boiling dangerously in a heating system?

a)

Steam in the loft area

b)

Cold water discharge

c)

No water flow

d)

Low water pressure

28.

If a cylinder stat fails, the water will continue to heat but will be controlled by the boiler stat, which should cut out at approximately ____.

a)

60-65°C

b)

70-75°C

c)

80-85°C

d)

90-95°C

29.

What is a common cause of cold water warming up in pipes?

a)

Cold water pipes are too far from hot water pipes.

b)

Hot water pipes are too close to cold water pipes.

c)

Cold water pipes are insulated.

d)

Hot water pipes are below cold water pipes.

30.

According to BS8000 pt15, the hot pipe should be installed ______ the cold pipework.

a)

below

b)

above

c)

next to

d)

inside

31.

What is a common indicator of air locks in pipework?

a)

Continuous water flow

b)

No flow of water or intermittent water flow

c)

High water pressure

d)

Low water temperature

32.

Air locks generally occur in low pressure systems when pipework is not installed correctly. A common situation is when horizontal pipework slightly rises, allowing air to be trapped. What should be done to prevent this?

a)

Increase water temperature

b)

Install pipework correctly

c)

Decrease water pressure

d)

Use larger pipes

33.

What is a common cause of blockages in a system?

a)

High water pressure

b)

Debris in the system

c)

Low temperature

d)

Excessive use

34.

To resolve blockages, one should remove and clean ______.

a)

pipes

b)

filters

c)

valves

d)

tanks

35.

What is a common cause of blockages and reduced efficiency in hard water areas?

a)

Rust

b)

Limescale

c)

Algae

d)

Mold

36.

Limescale is most noticeable on shower heads where the flow rate reduces over time. To prevent this, you should install a ______.

a)

Water filter

b)

Water softener

c)

Scale inhibitor

d)

Pressure valve

37.

Which of the following is a basic fault to check in maintenance?

a)

Temperature settings

b)

Color of the device

c)

Brand name

d)

User manual

38.

In maintenance, always look at the basics first. Which of the following should be checked? A) Timer settings B) Warranty period C) User reviews D) Packaging. Fill in the blank: Always check the ______ settings first.

a)

Timer settings

b)

Warranty period

c)

User reviews

d)

Packaging

39.

What happens when temporary hard water is heated above 65ºC?

a)

It becomes soft water

b)

It loses its calcium and limescale is formed

c)

It evaporates

d)

It freezes

40.

Temporary hard water can cause maintenance problems in plumbing systems because ______.

a)

It is too cold

b)

It forms limescale

c)

It is too acidic

d)

It evaporates quickly.