ELEC 17001

Total questions: 30

Worksheet time: 23mins

Name
Class
Date
1.

Class II electrical equipment exposures are designed to resist the:

a)

Ingress of gases

b)

Ingress of liquids and dust

c)

Ingress of solids only

d)

Ingress of air

2.

Define the term grounded conductor.

a)

The conductor that carries current to the load

b)

The conductor that is always live

c)

The system or circuit conductor that is intentionally grounded

d)

The conductor that connects to the neutral bus

3.

Fittings with machine faces must be used on:

a)

Class 1, Zone 0

b)

Class 2, Zone 1

c)

Class 3, Zone 2

d)

Class 4, Zone 0

4.

Electrical equipment installed in an explosive atmosphere location shall be marked:

a)

Exd

b)

Ex

c)

Exp

d)

Exi

5.

An overload device protects a motor from overcurrents which are caused by:

a)

Short circuits only

b)

Ground faults only

c)

Blocked rotors and increased loads

d)

Voltage spikes

6.

A Class III location is defined as:

a)

Areas with flammable gases

b)

Areas with flammable liquids

c)

Areas where there is a danger of explosion due to the presence of fibers and flyings

d)

Areas with high humidity

7.

A submersible pump system for a water well operates at 120V. Determine the type of receptacle that the pump must be connected to:

a)

Standard receptacle

b)

GFCI

c)

AFCI

d)

Weatherproof receptacle

8.

Identify the most suitable type of fitting that can be used with EMT conduit in a location that is damp or corrosive.

a)

Standard fitting

b)

Weatherproof fitting

c)

Corrosion-resistant fitting

d)

Explosion-proof fitting

9.

The circuit protective device which can protect circuits from arcing faults describes a/an:

a)

GFCI

b)

AFCI

c)

Circuit breaker

d)

Fuse

10.

How shall AC systems be grounded?

a)

On the load side of the service disconnect

b)

On the line side of the service disconnect

c)

At the neutral bus

d)

At the main panel

11.

According to the NEC/T&T electric codes, conductors that supply a single motor used in a continuous duty application shall have an ampacity of not less than ______ percent of the motor full-load current (FLC) rating.

a)

100

b)

115

c)

125

d)

150

12.

A device which can be manually operated or operates automatically at pre-determined overloads and short circuit currents defines a/an:

a)

Fuse

b)

Relay

c)

Circuit breaker

d)

Disconnect switch

13.

What are the wiring methods for Class II environments?

a)

NM cable

b)

PVC conduit

c)

RMC conduit

d)

EMT conduit

14.

Weatherproof fittings can be used in __________ locations.

a)

Class 1, Zone 0

b)

Class 1, Zone 1

c)

Class 1, Zone 2

d)

Class 2, Zone 0

15.

Indoor dielectric equipment containing more than 23 L of liquid in one tank or more than ______ L in a group of tanks shall be located in an electrical equipment vault.

a)

69

b)

50

c)

100

d)

120

16.

In a fuel dispensing Class 1 Division 1 location, conduit seals for enclosures shall normally be installed within a distance from the enclosure of:

a)

6 inches

b)

12 inches

c)

24 inches

d)

18 inches

17.

In bulk storage plants, the internal space of a tank shall be considered a ________ location.

a)

Class 1, Zone 1

b)

Class 2, Zone 0

c)

Class 3, Zone 0

d)

Class 1, Zone 0

18.

Electrical equipment installed in Class II atmospheres must be:

a)

Waterproof, explosion-proof

b)

Dust-tight, corrosion-resistant

c)

Weatherproof, ignition-proof

d)

Dust-proof, ignition-proof

19.

Solidly grounded systems have a grounding electrode conductor and a grounding electrode which are the main parts of its grounding system. The impedance of these systems shall be:

a)

Not more than 0.5Ω

b)

Not more than 1Ω

c)

Not more than 2Ω

d)

Not more than 5Ω

20.

A three-phase 15HP motor is connected to a 460V supply and has a FLC of 21A. If the overcurrent device is a fuse, then the overload must be set at:

a)

100% of 21A

b)

150% of 21A

c)

200% of 21A

d)

300% of 21A

21.

According to the Trinidad and Tobago wiring code (TTS-171-PART1-2015), every motor starting equipment must be provided with a disconnecting means which will open all ungrounded conductors. The rating of the disconnecting means shall be rated:

a)

Not less than 100% of the full load current rating of the motor

b)

Not less than 115% of the full load current rating of the motor

c)

Not less than 125% of the full load current rating of the motor

d)

Not less than 150% of the full load current rating of the motor

22.

The minimum clearance between non-insulated bus bars and enclosures in switchgears is:

a)

100MM

b)

150MM

c)

200MM

d)

250MM

23.

A Class I location is defined as:

a)

Areas where there is a danger of explosion due to the presence of flammable vapors, gases, and liquids

b)

Areas with flammable dust

c)

Areas with fibers and flyings

d)

Areas with high humidity

24.

A Class II location is defined as:

a)

Areas with flammable gases

b)

Areas where there is a danger of explosion due to the presence of flammable dust

c)

Areas with fibers and flyings

d)

Areas with high humidity

25.

Which circuit protective device will automatically operate when current draw exceeds its normal operating limit?

a)

Overcurrent

b)

GFCI

c)

AFCI

d)

Disconnect switch

26.

What properties must wiring in Class III environments have?

a)

Waterproof, explosion-proof

b)

Dust-tight, corrosion-resistant

c)

Weatherproof, ignition-proof

d)

Fiber-tight, ignition-proof

27.

In a heating element system, the part responsible for generating heat is called the:

a)

Coil

b)

Terminal

c)

Element

d)

Insulator

28.

A three-phase 15HP motor is connected to a 460V supply and has a FLC of 21A. If the service factor on the nameplate is 1.15, then the overload must be set at:

a)

100% of 21A

b)

115% of 21A

c)

125% of 21A

d)

150% of 21A

29.

What is the main purpose of grounding?

a)

To improve electrical efficiency

b)

To protect life from danger of shock

c)

To reduce energy consumption

d)

To increase voltage stability

30.

GFCI devices operate when:

a)

There is a voltage drop

b)

There is a current difference of 10 milliamperes

c)

There is a short circuit

d)

There is a current difference of 4 to 6 milliamperes