1.

Use the software to create a LAD that illustrates the operation of RS latching relay in a described application and then simulate the program

4 lines
2.

Use the software to create a LAD that illustrates the operation counter for a given application.

4 lines
3.

Apply latching principle to start and stop a motor using simple logic blocks in FBD and LAD

4 lines
4.

Use latching principle to start and stop a motor using RS relay in FBD and LAD

4 lines
5.

Justify the safety reasons behind using NC push button to stop the motor instead of NO pushbutton with the aid of circuit diagram and LAD

4 lines
6.

Identify the relay contacts and coil terminals of the replay with the aid of circuit diagram

4 lines
7.

Identify the status of relays contacts (open / close) in a reversible motor control circuit with the aid of circuit diagram

4 lines
8.

Program the PLC to display a message on the PLC display unit using the ‘message text’ block. Use LAD/FBD to display the message.

4 lines
9.

Create a LAD and describe the circuit diagram for starting and stopping a motor in an unsafe stop method when using NO stop pushbutton.

4 lines
10.

Create a LAD and describe the circuit diagram for starting and stopping a motor in a safer stop method when using NC stop pushbutton.

4 lines
11.

Carry out a practical activity to control a motor rotation using Interlocks. The motor is connected to the PLC using a relay. Use the PLC and software available in the workshop to conduct the activity.

4 lines
12.

Create a LAD and describe the circuit diagram for starting and stopping a motor in an unsafe stop method when using NO stop pushbutton.

4 lines
13.

Create a LAD diagram and describe the circuit diagram for starting and stopping a motor in a safer stop method when using NC stop pushbutton. In your description, Justify the safety reasons behind using NC push button to stop the motor instead of NO pushbutton with the aid of circuit diagram and LAD.

4 lines
14.

Take a clear photo of the pin diagram that identify the coil terminals and contacts assignment of the relay used in the circuit.

4 lines
15.

Refer to the below internal wiring diagram for an OMRON 12 VDC relay and answer the following question: Fill in the table provided below by writing the assigned numbers of each input and output.

4 lines
16.

For the three scenarios provided in the table below, identify the status of relay contacts (open/close) in a reversible motor control circuit by drawing the relay contact’s status in the empty spaces. The relay symbol is provided below.

4 lines
17.

Wire the LOGO! as shown in Figure 1. Connect the motor to the two relays. Note that the relay connection depends on the type you use. Refer to the pin diagram on the relay for its specification. Use both the hardware (Figure 1) and software interlock for safety.

4 lines
18.

Test the functionality of the circuit using a program created using the LOGO!Soft Comfort. Apply latching principle to start and stop a motor using simple logic blocks in FBD and LAD.

4 lines
19.

Test the functionality of the circuit using a program created using the LOGO!Soft Comfort. Apply latching using RS latching in FBD and LAD.

4 lines
20.

Derive the Boolean expressions for the output in forward and reverse directions.

4 lines
21.

Analyze and design an automatic door control system using the four implementation sequence steps.

4 lines
22.

Create the inputs assignment list.

4 lines
23.

Create the outputs assignment list.

4 lines
24.

Write the ON requirements of the outputs.

4 lines
25.

Derive the Boolean expressions from the ON requirements above.

4 lines
26.

Based on the system requirement table select the appropriate LOGO! controller from the devices list.

4 lines
27.

Create your LAD or FBD using the LOGO!Soft Comfort to implement the conditions listed above.

4 lines