Wayground logo

Free Printable Worksheets

Font size

S
M
L
XL
Worksheets

QUIZ4-EMD

Total questions: 10

Worksheet time: 5mins

Name
Class
Date
1.

What is the usage of the tanks with tubes?

a)

if the temperature rise with plain tank is very low

b)

if the temperature rise with plain tank is very high

c)

if the temperature rise is zero

d)

if the temperature rise with plain tank exceeds the specific limits

2.

What is the relation of the provision of tubes with respect to dissipation of heat?

a)

the provision of tubes is directly proportional to the dissipation of heat

b)

the provision of tubes is indirectly proportional to the dissipation of heat

c)

the provision of tubes is directly proportional to square of the dissipation of heat

d)

the provision of tubes is indirectly proportional to square of the dissipation of heat

3.

What is the relation of the transformer surface with respect to dissipation of heat?

a)

transformer surface has no relation with respect to dissipation of heat

b)

transformer surface has minor changes with respect to dissipation of heat

c)

transformer surface has major changes with respect to dissipation of heat

d)

transformer surface has no change with respect to dissipation of heat

4.

How is the circulation of oil improved in tanks with tubes?

a)

it can be improved by using dissipating heat

b)

it can be improved by using more effective air circulation

c)

it can be improved by using more effect power flow

d)

it can be improved by using more effective heads of pressure

5.

An addition of 35 percent should be made to tube area of the transformers.

a)

true

b)

false

6.

What is the loss dissipated by tubes by convection, given area of the tubes = 3.5?

a)

12.3 W per °c

b)

2.51 W per °c

c)

5.3 W per °c

d)

30.8 W per °c

7.

What is the formula for temperature rise with tubes?

a)

temperature rise with tubes = total loss / dissipating surface*(12.5 + 8.8x)

b)

temperature rise with tubes = total loss * dissipating surface*(12.5 + 8.8x)

c)

temperature rise with tubes = total loss / dissipating surface / (12.5 + 8.8x)

d)

temperature rise with tubes = total loss + dissipating surface*(12.5 + 8.8x)

8.

What is the formula for number of tubes?

a)

number of tubes = (1/ 8 * area of each tube) * (total loss / temperature rise with tubes – 12.5 * dissipating surface)

b)

number of tubes = (1* 8 * area of each tube) * (total loss / temperature rise with tubes – 12.5 * dissipating surface)

c)

number of tubes = (1/ 8 * area of each tube) / (total loss / temperature rise with tubes – 12.5 * dissipating surface)

d)

number of tubes = (1/ 8 * area of each tube) + (total loss / temperature rise with tubes – 12.5 * dissipating surface)

9.

What is the range of the diameter of the tubes used?

a)

50-60 mm

b)

60-70 mm

c)

70-80 mm

d)

50-70 mm

10.

What is the formula for width of the tank for single phase transformers used?

a)

width of tank = 2*distance between adjacent limbs + external diameter of h.v windings + 2*clearance between h.v windings and tank

b)

width of tank = distance between adjacent limbs + external diameter of h.v windings + 2*clearance between h.v windings and tank

c)

width of tank = 2*distance between adjacent limbs * external diameter of h.v windings + 2*clearance between h.v windings and tank

d)

width of tank = distance between adjacent limbs * external diameter of h.v windings + 2*clearance between h.v windings and tank