wayground logo

Free Printable Worksheets

Font size

S
M
L
XL
Worksheets

141 final review 2

Total questions: 25

Worksheet time: 13mins

Name
Class
Date
1.

In order to deliver different volumes of air to various areas in an occupied space, the blowers used on VAV systems must be able to modulate their openings to accommodate the changing needs of the system.

a)

True

b)

False

2.

By raising the forearm in the air, index finger pointing upward and holding the hands straight, the operator will know to raise the cable on the crane.

a)

True

b)

False

3.

Curbs can be prefabricated, but many larger curbs are shipped unassembled.

a)

True

b)

False

4.

Gasketing materials and foam panels that are shipped with the curb are not part of the curb and should be discarded.

a)

True

b)

False

5.

By utilizing a strategy called demand control ventilation, DCV, the amount of outside air being brought into the building can be varied based on the actual occupancy level in the structure.

a)

True

b)

False

6.

Improper clearances do not affect the ability of service personnel to perform their jobs adequately.

a)

True

b)

False

7.

The curb’s cross braces are intended to support the duct connections to the unit, but not the entire air distribution system.

a)

True

b)

False

8.

Although packaged air-conditioning equipment comes precharged with refrigerant and no field piping must be done, the installation of a rooftop package unit involves many steps and can be very dangerous.

a)

True

b)

False

9.

Package units are factory-assembled, factory-charged, self-contained systems that have all of the major system components contained in a single housing.

a)

True

b)

False

10.

The rooftop unit houses the fans and blowers that move air through the heating and cooling portions of the unit but not through the condenser.

a)

True

b)

False

11.

Some roofs are bonded, which are roofs that carry a written warranty or insurance policy that protects the building owner in the event damage from leaks occurs.

a)

True

b)

False

12.

The term enthalpy refers to the total heat content in the air, which accounts for both the temperature (sensible heat portion) and the moisture content (latent heat portion) of the air.

a)

True

b)

False

13.

Be sure to provide proper and adequate support for the duct system according to ____.

a)

installation instructions

b)

local building codes

c)

state building rules

d)

environmental regulations

14.

An enthalpy sensor includes solid state temperature and ____ sensors.

a)

entropy

b)

barometer

c)

pressure

d)

humidity

15.

The unit’s location should be carefully selected so the system’s operation is not adversely affected by air being able to ____ the condenser coil.

a)

bypass

b)

circulate back through

c)

recirculate

d)

induce cooling in

16.

With both fists in front of the body, pointing the thumbs outward tell the crane operator to ____ the boom.

a)

retract

b)

rotate

c)

extend

d)

lower

17.

It is good field practice to double-check and possibly triple-check the ____ decision, since the cost of repairing an improperly cut roof can be very high.

a)

location

b)

size

c)

capacity

d)

operational

18.

By tapping his fist on his ____, the crew member is telling the crane operator to use the main hoist.

a)

head

b)

wrist

c)

arm

d)

shoulder

19.

It should be noted that, in most cases, the supply and return ductwork must be attached to the ____ before the unit is set in place.

a)

boom

b)

package

c)

load

d)

curb

20.

____ are intended to help provide the correct amount of ventilation and also help reduce cooling costs by allowing outside air to be introduced to the conditioned space when conditions are correct.

a)

Minimizers

b)

Maximizers

c)

Economizers

d)

Recirculators

21.

Rooftop units are often positioned ____ the space that is to be served by the equipment.

a)

directly below

b)

directly behind

c)

directly adjacent

d)

directly above

22.

The fans that move air through the air-cooled condensers are of the ____-type.

a)

propeller

b)

squirrel

c)

cage

d)

push

23.

The amount of refrigerant indicated on the ____ is the total refrigerant charge for the unit, not simply a holding charge as in the case of a split-type system.

a)

bill of lading

b)

compressor

c)

nameplate

d)

blower

24.

The economizer is able to increase or decrease the amount of outside air that is brought into the structure with two ____.

a)

blowers

b)

dampers

c)

valves

d)

diverters

25.

If the curb is mounted as part of a new construction process, it can be assembled and installed as soon as the ____ support system is in place.

a)

walls

b)

ceiling

c)

roof

d)

utility