Font size
WorksheetsSafety X Session 2 Review
Total questions: 30
Worksheet time: 16mins
Maximum allowable free fall distance for a work positioning device?
2 Feet
3.5 Feet
6 Feet
4 feet
Fall Arrest systems are used on vertical surfaces?
True
False
Which system is most commonly used while climbing a pole?
Fall Arrest
Work Positioning
Ladders
None of the above
The maximum deceleration distance for fall arrest is?
6 Feet
4 Feet
2 Feet
3.5 Feet
At what height is work positioning equipment required?
2 Feet
4 Feet
3.5 Feet
6 Feet
An anchor point in a fall arrest system must be 5000 lbs.
True
False
What class of rubber glove would you wear on a 24.9kV system?
Class 2
Class 1
Type II
Class 3
(a) is the ability of a piece of equipment or conductor to hold a charge?
Induction
Static
Lightning
Specifically built to handle high fault current, on the system, well designed and tested
System Neutral
Static Wire
Temporary Ground Rod
Substation Grid
The 5 Steps of the grounding process in order?
Identify, Test, Clean, Ground, Disconnect
Identify, Disconnect, Clean, Test, Ground
Identify, Disconnect, Test, Clean, Ground
None of the above
Which is one of the objectives of grounding lines?
Limit the current flow and voltage drop across the worker's body
Increase the Fault Current
To increase the voltage level to minimum trip
Decrease the overall resistance of the circuit
When current from a foreign source travels backward onto the powerline?
Induction
Capicitance
Lightning
Backfeed
When rubber gloving it is always important for the linework to cover all differences of potential with are know as?
Secondary Conductors
Second Points of Contact
Insulated X arms
Transformer Banks
The image below is known as a?
Grounding Jumper
Load By-Pass Jumper
Orange Disconnect Jumper
Temporary Jumper
The body harness must have a maximum arresting force of?
900 lbs
1800 lbs
5,000 lbs
3500 lbs
Work positioning equipment consists of?
Body Belt & Lanyard
Lanyard & Harness
Body Belt & Pole Choking Device
Pole Choking Device and Lanyard
Which of the following is not part of a fall arrest system?
Rip Stitch Lanyard
Harness
Anchorage
Super Squeeze
The image below is known as a?
Orange Pole Marker
Plastic Guy Guard
Pole Guard
X-arm Cover
The image below is an example of?
Plastic Cover Up
Rubber Gut
Cross Arm Cover Up
Orange Thingy Ma Bob
Extremely large levels of voltage up to 100 million volts?
Backfeed
Lightning
Induction
Capacitance
Wind can cause static voltage on a powerline?
True
False
Minimum size of grounding jumpers as prescribed by OSHA
2/0 AWG
#2 AWG
1/0 AWG
4/0 AWG
(a) is the amount of current a power system can deliver to a short circuit?
Static
Load
Type I rubber gloves are ?
Orange
Not Ozone Resistant
Ozone Resistant
Rated at 30kV
Typically found on transmission lines and serves as lightning protection?
System Neutral
Static or Shield Wire
Guy Leads
Insulators
When parallel or adjacent lines energize a deenergized power line running next to it?
Backfeed
Capacitance
Induction
Static Voltage
OSHA requires that all live line tools be tested and removed from service how often?
2 months
2 years
Before each use
36 months
Match the ground sources.
Static/Shield wire
On transmission line to w/with lightning
Temp Grounding Rod
Screw ground placed as deep as possible
Substation Ground Grid
Designed to handle high fault levels
Waist size is commonly used to find "D" ring size for body belts
False
True
What is this image depicting?
Line line tool
Pole Guard
Insulator cover
Line guard
