Wayground logo

Free Printable Worksheets

Font size

S
M
L
XL
Worksheets

PLUMBING-PRACTICE PROBLEMS

Total questions: 112

Worksheet time: 59mins

Name
Class
Date
1.

Which of the following plumbing code in USA does the National Plumbing Code of the Philippines was being patterned for?

a)

Standard Plumbing Code

b)

ASPE Code

c)

Uniform Plumbig Code

d)

International Plumbing Code

2.

The appropriate sealant that will be used to cover void spaces between pipes and sleeves through concrete floors in the ground

a)

Bitumen

b)

Epoxy

c)

Grease

d)

Putty

3.

What is the shape for the signage for women's comfort room in order to aid visually impaired women readilty whether a washwoom is for men or women?

a)

Circle

b)

Rectangle

c)

Triangle

d)

Square

4.

What is the maximum height should a watercloset have if it is intended for a disabled person

a)

0.40 m

b)

0.50 m

c)

0 .45 m

d)

0 .35 m

5.

When shall the installation of plumbing equipment to supply building or structures from existing water supply system only be allowed to?

a)

Whenever the water supply is scantity available

b)

If the water demand is inadequate

c)

When there is always water in the main

d)

When water is not available in the vicinity

6.

What is the minimum dimension for a turning space in a water closet stall intended for disabled persons?

a)

2 m

b)

1.2 m

c)

1 m

d)

1.5 m

7.

Whatis the minimum pipe size of the standpipe if the highest outlet is located 23 m orless above the fire service connection?

a)

3 in

b)

6 in

c)

5 in

d)

4 in

8.

When permitted by DENR, which of the following below is NOT used as a basis in determining the type of the private sewage disposal system to be used?

a)

Soil porosity

b)

Ground water level

c)

Number of occupants

d)

Location

9.

Where should the overflow pipe lead for overhead tank on buildings?

a)

Soil stack

b)

Scuppers

c)

Storm drain

d)

Gutter

10.

What installation standard is followed in joining plastic pipe and fittings by solvent cement?

a)

ISO

b)

ANSI

c)

IAPMO

d)

ASHRAE

11.

Whenever pipings is pressurized by a pump or ejector , what kind of pipe should not be used in the excreta dfrainage system?

a)

Vitrified clay pipe

b)

Hubless cast iron

c)

Galvanized wrought iron

d)

None of these

12.

What shall be the issues Administrative Authority for the construction of a part of s large and/or complicated plumbing system before the entire plans and specifications for the whole system have been submitted or approved?

a)

Restraining order

b)

Partial permit

c)

Summon

d)

Evaluation sheet

13.

What is the minimum diameter of vent pipe is allowed in the revised code?

a)

1 in

b)

1 1/4 in

c)

2 in

d)

1 1/2 in

14.

What kind of cleanout plugs that will be installed in case where iraised heads may caused hazards tk passing the personnel or vehicles

a)

Depressed

b)

Countersunk

c)

Embedded

d)

Recessed

15.

Who has the power yo remove any member of the noard of master plumbers for neglect of duty, incompetence, malparactice and unprofessional or dishonorable coduct?

a)

President of the Philippines

b)

Civil Service Commissioner

c)

Cairman of PRC Commissioners

d)

Commission on Appointments

16.

Unless prohibited by structural conditions, what is the reference of each vertical vent pipes before offsetting horizontally to join the stack or vent stack?

a)

Invert or trap

b)

Air gap of fixture

c)

Water level inside the trap

d)

Highest flood level rimof the fixture

17.

What is the minimum age requirement for an appointee to become a member of the board of aster plumbers?

a)

30 yrs old

b)

28 yrs old

c)

32 yrs old

d)

35 yrs old

18.

What is the minimum pipe size of the standpipe if the highest outlet is located more thsn 23 m above the fire service connection?

a)

3 in

b)

6 in

c)

5 in

d)

4 in

19.

What shape of signage is shown for mens showroom?

a)

Square

b)

Circle

c)

Triangle

d)

Rectangle

20.

What congress of the republic of the philippines apprived after the third reading rep. Act 1378 otherwise known as the plumbing code od the philippines?

a)

Third congress

b)

Sixth congress

c)

Second congress

d)

Fifth congress

21.

What type of pvc female screws for water pipong is prohibited under the cide?

a)

Tapped

b)

Job fabricated

c)

Seamless

d)

Schedule 20 screws

22.

What is the minimum horizontal clear distance from the septic tank to the property line of the adjoining private property?

a)

1 m

b)

1.2 m

c)

1.5 m

d)

1.8 m

23.

According to the fire code of the philippines, what is the required slope of allhorizontal runs of dry standpipes system for the purpose of drawing?

a)

10%

b)

20%

c)

5%

d)

2%

24.

Under the accessibility law, what is the minimum area of water closet stalles?

a)

1.7 x 1.8 m

b)

2x2 m

c)

1.5 x 1.8 m

d)

1.2 x 2 m

25.

What is the maximum water pressure must stand pipe fittings and connections must with stand to when ready for service?

a)

21 kg/cm²

b)

3r kg/cm²

c)

15 kg/cm²

d)

8 kg/cm²

26.

The following are the data required whenever a registered master plumber sign the blueprint of the building plan except

a)

Date of prc registration

b)

PTR Date

c)

Registration expiry date

d)

None of these

27.

What portion of the trap should the vent pipe opening will not go belowe from the a soil or waste oipe?

a)

Slip joint

b)

Weir

c)

Sleeve

d)

Seal

28.

According to batas pambasa blg.344, what type of urinal should be provided for disabled persons?

a)

Wall-hung type

b)

Pedestal type

c)

Trough type

d)

None of these

29.

What is the type of siamese connection that all 125-mm dry standpipes shall be equipped with?

a)

Three-way

b)

Two-way

c)

Four-way

d)

One-way

30.

The minimum requirement for the slope of horizontal drainage pipes between manholes is?

a)

2%

b)

2 2/1 %

c)

3%

d)

4%

31.

In sizing the grease interceptors, four elements are being used. Two of these elements are number of meals per peak hour and the waste flow rate. What are the other two elements?

a)

Slope and retention time

b)

Storage factor and time and concentration

c)

Retention time and storage factor

d)

Precolation rate and time of concentration

32.

For new, additional or altered plumbing installation not exceeding 20 units, the building codesrated that a licensed master plmber could sign and affix his seal on the following engineering documents except

a)

Plumbing plan and layout

b)

Design analysis and plans of the original installation

c)

Ometric drawing

d)

Guide specifications and bill of materials

33.

For the hot and cold water distribution systemm on what side should hot water supply be placedin combination fittings?

a)

Left

b)

Right

c)

Center

d)

None of these

34.

What is the minimum number of years of experience must a registered master olumber before he can be a technical staff of a building office?

a)

One year

b)

Three years

c)

Two years

d)

Five years

35.

Except for plastic piping system, hot and cold water piping may be tested with

a)

50 psi of the working pressure of the water in the system for atleast 15 minutes

b)

100 psi air for at least 15 minutes

c)

35 psi air for at least 15 minutes

d)

40 psi air or 150 psi water for 10 minutes

36.

To allow cleaning of the soil and waste line each cleanout should be installed

a)

In the direction of flow

b)

Opening upward

c)

Vertically above flow line

d)

All of these

37.

The building code stated that all dry standpipe outlets shallge equipped with valves having substantial chains. What kind of valve is this?

a)

Check valve

b)

Globe valve

c)

Gate valve

d)

Ball valve

38.

Which of the following is not considered as suds-producing fixture?

a)

Kitchen sink

b)

Bath tub

c)

Washing machine

d)

Bidet

39.

What kind of comcealed connections on fixtures that it is required to provide an access panel or utiity at least 0.30 m in its least dimension for easy inspection and repair?

a)

Slip joint

b)

Ball and socket

c)

Hubbles

d)

Flange

40.

Unless erving sunks or urinals, cleanouts may be omitted on anhorizontal drain line that is

a)

Equal to 2 meters

b)

Greater than 2 meters

c)

Lss than 1.5 meters

d)

None of these

41.

Within how many days upon the approval of rep. Act no 1378 does it require to have a board of examiners for master plumbers formed?

a)

Thirty days

b)

Forty five days

c)

Sixty days

d)

Fifteen days

42.

According to the code, the design of roof gutters is based on the maximum roof area. What is the shape of the guyter does the design table for storm seweris being use to?

a)

Circular

b)

Rectangular

c)

Ovate

d)

Semi-circular

43.

What government agency is tasked to set the criteria in the discharge of sanitary sewage from buildings or pretreated industrial wastewater directly into the nearest sanitary sewer main?

a)

National pollution control commission

b)

Dept of environment and natural resources

c)

Dept of healt

d)

Dept of public works and highways

44.

What is the maximum distance as where supports of vertical cast iron soil pipes are made?

a)

Every 3 m

b)

Every meter

c)

Every storey

d)

Every joint

45.

In the water test of the entire plumbing system all opening should be tightly closed except at

a)

Producing cleanouts

b)

Highest opening

c)

Stack vent

d)

Bleeders

46.

What is the minimum of approved slip joints fittings maybe usedon the outlet side of the trap

a)

Three

b)

Two

c)

None

d)

One

47.

If the discharge of a fixture or drain may contain solids or semisolids heavier than water that would be harmful to the drainage system or caused stoppage within the system, when the discharge must pass first?

a)

Sand interceptor

b)

Screen wire mesh

c)

Wooden baffle

48.

What is the standard specification must all pipe materials must conform to

a)

Product standard of the philippines

b)

Internationsl producers standard

c)

Philippine standard council

d)

Department of trade and industry

49.

Aside form galvanized steel, what is tge other material for dry standpipe that the building code allows?

a)

PVC pipe

b)

Wrought iron

c)

PE pipe

d)

Brass

50.

For at least how many working days shall a required for inspection of the plumbing works be filed before such inspection be intended?

a)

7 working days

b)

5 working days

c)

3 working days

d)

10 working days

51.

What is the fee if an expired plumbing permit is renewed?

a)

P 150.00

b)

Equal to the original fee

c)

Double of the original fee

d)

1/2 of the original fee

52.

Who is empowered to administer the provision of rep act 1378?

a)

Office of the pres

b)

Conress of the phil

c)

The board of examiners for master plumbers

d)

PRC

53.

If a septic tank has a compartment that exceed 3.7 m in length, what should be the additional requirement?

a)

An additional manhole

b)

Increase the size of the leaching chamber

c)

Increase the number of compartments

d)

Baffle wall is added

54.

What institution standard used as a reference for joining pipes

a)

ASSE

b)

ASPE

c)

ANSI

d)

IAPMO

55.

One of the code of ethics for master plumber staes "take advantage of a salaried______ position to complete unfairly with a practicing master plumber. What is the missing word?

a)

Higher

b)

Government

c)

Private

d)

Competent

56.

If ever pipes are to pass through masonry by using pipe sleeves, how far must each pipe be from each other?

a)

Minimum of three dia, center to center

b)

Minimum of three dia flushed from each hole

c)

Minimum of 0.15 m on centers

d)

Maximum of two dia on centers

57.

Under what law did plumbing became a duly recognized profession by the philippine government

a)

National plumbing code of the phil 1959

b)

Tydings mcduffie act of 1905

c)

Jones law of 1907

d)

Republic act 1378

58.

Of the four subjects given for master plumbers examination, which of this subject was originally split into two subject?

a)

Practical problems

b)

Design and installations

c)

Plumbing code

d)

Plumbing arithmetic

59.

What can a vertical piping be considered to be wet vented?

a)

Between openings of vent pipes

b)

Between any two consecutive inlet levels

c)

On stack vent

d)

When serving two water closets at different level

60.

What should be done whenever a partition contains some piping and runs parallel to the floor joist underneath?

a)

Notching should be introduced into the joist

b)

Adjust the joist yo make it perpendicular with the direction of pipe

c)

Space the joist wider to accommodate the pipe

d)

Double the joist

61.

A fitting for lead caulked joint that is prohibited when in vertical position

a)

Single hub

b)

Double hub

c)

Diuble tapped tee

d)

All of these

62.

Who is the first charter president of NAMPAP

a)

Antonio Mansueto Sr.

b)

Cornelio G. Odvina

c)

Jesus TAnghal Dera

d)

Catalino C. Casupanan

63.

Wet venting is applied whenever

a)

There are 1 or 2 fixtures at every level

b)

Fixtures are of the same level

c)

Fixtures are not vented individually

d)

None of these

64.

How does a pneumatic tank be designed to supply adequate water pressure in all floors of a building that willbe in a ccordance with the building code?

a)

Twice the maximum totsl dynamic pressure required

b)

Equal to the total water supply fixture units

c)

Twice the total demand per capita

d)

Equal to the total dynamic head and minus all the headloss

65.

Where practical, all pipes from fixtures shall be run in what direction with respect to the nearest wall or building line?

a)

Offset

b)

Parallel

c)

Across

d)

Perpendicular

66.

Within hiw many meters away shall unions be installed from regulating equipment, water heater, conditioning tank and similar equipment which require removal for servicing or replacement?

a)

2 ft

b)

1 m

c)

5 ft

d)

0.3 m

67.

Drainage piping serving fixtures located below the crown level of the main sewer shall discharge into an approved water tight

a)

Septic tank

b)

Sump

c)

Cesspool

d)

Leaching tank

68.

In the excreta drainage system, which of the following pipe materials should not be used underground?

a)

Vtrified clay pipe

b)

Hubbles cast iron

c)

Galvanized wrought iron

d)

None of the above

69.

NAMPAP is a professional organization of registered master olumber under PRC. What is the PRC accreditstion number of NAMPAP?

a)

10

b)

14

c)

18

d)

12

70.

In accordance to the building code, what must be provided in addition to deptic tanks by building located areas where there is no sanitary sewage system whenever they will dispose their waste?

a)

Baffle plate

b)

Subsurfsce absorption filed

c)

Imhoff tanks

d)

Settling chamber

71.

What kind of septic tank is prohibited?

a)

Concrete

b)

Steel

c)

Plastic

d)

Wooden

72.

What is the minimum height of raised letters on an iron or bronze sign that will read " CONNECTION TO DRY STANDPIPE"?

a)

20 mm

b)

1/4 inch

c)

25 mm

d)

30 mm

73.

The ff are ground for non-issuance of the certificate of registration by the board of master plumbers except

a)

Convicted by court for any criminal offense

b)

Of unsound mind

c)

Guilty of immoral or dishonorable conduct

d)

Failure to pay the required fees

74.

To what provision does the design, construction, and operation of deep well for the abstraction of ground water will have to follow?

a)

NPCP

b)

Nstional standards for drinking water

c)

Water code of the phil

d)

Code of sanitation

75.

Who among the board examiners is not a signatory to prc resolution 04 that request for the adoption and promulgation of the revised national plumbing code of the phil in 1999?

a)

Imelda Perez

b)

Aida Emely Luz

c)

Fortunato Amosco

d)

Jesus Pacheco

76.

What is the minimum floor area in every storey which is used for habitstion, recreation, dining, study of work and which has an occupied load of not more than 20, wherein a standard automatic extinguishing system is a

a)

300 sq.m

b)

200 sq.m

c)

400 sq.m

d)

500 sq.m

77.

Which of the ff could be omittdd if the trap arm changes direction that does not exceed 90 degress?

a)

Wye

b)

Cleanout

c)

Long sweep

d)

Combination of 1/8 bend and wye

78.

What is the maximum allowable lead content of pipe and fitting for potable piping system?

a)

0%

b)

2%

c)

5%

d)

8%

79.

Which of the ff is prohibited fixture inside a public toilet room?

a)

Faucet

b)

Drinking fountain

c)

Slop sink

d)

Bidet

80.

Aside from bell and spigot, B&S in the code means

a)

Ball and Socket

b)

Browning and Smith

c)

Butt and Soldered

d)

Brown and Sharp

81.

A plumbing permit shall expire and become null and void if the plumbing work authorized therein if not started for how many days?

a)

30 days

b)

45 days

c)

100 days

d)

365 days

82.

Building sewers shallbe tested by completely filling the sewer with water from the

a)

Lowest to the highest point

b)

Lowest to atleast ground level

c)

Lowest at least a 10-foot head

d)

Lowest to at least a 5 foot head

83.

What is the minimum number of water closet ina floor level wherein you have to provide 1 water closet for disabled persons as provided by batas pambansa blg 344? In excess of this number you have to provide 2.

a)

12

b)

15

c)

20

d)

10

84.

A stack, as defined in the code is

a)

Thr main vent

b)

Any vertical vent

c)

The horizontal main of soil, waste or vent stack

d)

The vertical main of soil, waste or vent piping that extends one or more stories

85.

According to the the building code of the phil, what is rsnge in height above grade should the siamese fire department connection be installed

a)

30 cm to 1.2 m

b)

60 cm to 1.5 m

c)

80 cm to 1.8 m

d)

50 cm to 1.0 m

86.

For howmany days shall the revised national plumbing code will take effect following its complete publication in the official gazette

a)

100 days

b)

60 days

c)

50 days

d)

30 days

87.

Which of the ff is not included in a plumbing unit?

a)

Water meter

b)

Floor drain

c)

Urinal

d)

Laundry tray

88.

What is the maximum length of the fire hose that shall be equipped on wet standpipes?

a)

12m

b)

23 m

c)

17 m

d)

25 m

89.

PD No. 1185 is another law that master plumbers used as their guide in the practice of the plumbing profession. What is PD No.1185?

a)

Accessibility law

b)

Fire code of the phil

c)

Water code of the phil

d)

Code of sanitation

90.

Except on what fixture does the vent pipe opening from the soil or waste pipe must not be below the weir of the trap

a)

Lavatory

b)

Kitchen sink

c)

Bath tub

d)

Water closet

91.

The coverof gravity tanks shall be vented using a screened

a)

Return bend pipe

b)

Upright pipe

c)

Horizonral nipple

d)

All of these

92.

How many units do the controversial article 3.2.2.2 of PD 1096 otherwise known as national building code limits the practice of master plumber?

a)

20

b)

10

c)

5

d)

50

93.

In irder as not to impede the movement of a person in wheel chair and to have a convenient access on the lavatory, what is the allowable knee recess vertical clearance that will be provided?

a)

0.5 to 0.8 m

b)

0.6 to 0.8 m

c)

0.4 m to 0.70 m

d)

0.60 to 0.70 m

94.

Eho is the current chairman of the board of examiners for master plumber?

a)

Fortunato Amusco

b)

Virgilio Simbulan

c)

Jessie Mariano

d)

Valerin Maogila

95.

In what year did NAMPAP was incorporated as s professional organization?

a)

1935

b)

1956

c)

1946

d)

1968

96.

Which of the ff is the primary basic for sizing vertical rainwater pipingin the revised national plumbing code?

a)

Intensity of rainfall

b)

Wind direction

c)

Slope of roof

d)

Roof area

97.

Aside from the number of fixture units connected to it, the size of the vent piping is determined by its

a)

Number of inlets

b)

Length

c)

Discharge

d)

Loading

98.

Where the number of water closets in a floor level exceeds 20, how many of these shall be provided to the disabled persons?

a)

1

b)

2

c)

3

d)

4

99.

A type of drainaage and benting system with universal branch line that is prohibited

a)

Single

b)

Dual

c)

Dependent

d)

Alternate

100.

For a vertical drainage linenthat is installed to be truly in vertical position, what is the allowed degree of the branch to be used?

a)

10

b)

45

c)

30

d)

60

101.

What is the PRC resolution number is issued by the board of master plumbing for the adoption and promulgation ofthe revised national plumbing code of the phil?

a)

Res. no 2

b)

Res no.1378

c)

Res no. 4

d)

Res no. 962

102.

Who is authorized to issue rules and regulations to carry intoeffect the objectives of rep act 1378?

a)

Board of master plumbers

b)

Congress of the phil

c)

President of the phil

d)

Professional regulation commission

103.

What is the minimum allowable interval for the support of plastic pipes when installed vertically

a)

2 ft

b)

5 ft

c)

1 m

d)

1.5 m

104.

Who shall set the criteria for the quality of drinking water from meteoric, surface or underground sources?

a)

National water resources board

b)

Department of health

c)

National standards for drinking water

d)

Department of environment and natural resources

105.

Who was awarded as the most outstanding registered aster plumber for the year 2011?

a)

Dave Vela

b)

Alberto Azarcon

c)

Alberto Cabael

d)

Thelma Cardente

106.

What is the minimum total net inlet areaof roof deck drains on roof deck used as sun decks and parking decks?

a)

Equal to the area of the outlet pipe

b)

Equal to 4 times the area of the outlet pipe

c)

Equal to 2 times the area of the outlet pipe

d)

Equal to 1 1/2 times the area of outlet pipe

107.

According to article 3.2.2.2 of PD 1096 what scope of work in plan preparation for new sanitary installations with more than 20 units does a sanirary engineer differs with a registered master plumber?

a)

Det. all drawings of septic tanks in the absence of disposal field

b)

Sanitary plan, layout and details

c)

Cost estimate

d)

Isometric drawings of roughing in

108.

What kind of joint is not allowed in cast iron pipe

a)

Welded

b)

Threaded

c)

Soldered

d)

Ball and Spigot

109.

What is the name of the professional organization for the registeeed master plumbers here in the phil?

a)

National association of master plumbing of the phil

b)

National association of master plumbers of the phil

c)

National master plumbers association of the phil

d)

National master plumbing association of the phil

110.

What is not needed to be installed when a combination standpipe system is installed in accordance with the fire code?

a)

Dry standpipe

b)

Wet standpipe

c)

Sprinkler system

d)

Siamese connection

111.

Article 3.2.2.2 of PD 1096 A

actually allows a registered master plumber to sign and seal plans for new sanirary installation sof more than 20 plumbing units. Aside from being a registered master plumber, what is the other requirement that you must have before you can sign and seal it?

a)

A registered engineer

b)

An engineering graduate

c)

Having a minimum experience of 5 years

d)

Member of NAMPAP

112.

In 1966-1969, the board of master plumber and NAMPAP prepared a curriculum for plumbing engineering and approved by the department of educ. What was the first school that inteoduced the plumbing engineering curriculum?

a)

FEATI University

b)

University of the phil

c)

Mapua institute of technology

d)

National university