1.

Where the allowable current rating of a busway does not correspond to a standard rating of overcurrent device, what rating is permitted?

a)

The next lower rating

b)

No overcurrent protection is required

c)

The next higher rating

d)

none of these

2.

A conduit run between outlets, between fittings, between outlet and fitting shall not contain more than the equivalent of m quarter bends.

a)

2

b)

3

c)

4

d)

5

3.

The difference between a neutral and a grounded circuit conductor is 1 ____.

a)

only a neutral will have equal potential to the ungrounded conductor

b)

only a neutrals outer covering is white or natural gray

c)

only a neutral carry unbalanced current

d)

there is no difference

4.

Which of the following receptacles may be connected to the small appliance branch circuit?

a)

Outside receptacles

b)

Electric clock in a dining room

c)

Hallway receptacle which is within 6 meters of kitchen

d)

Garage ceiling receptacle for automatic garage door open

5.

The connection between the grounded circuit conductor and the equipment grounding conductor at the service is called the _ bonding jumper.

a)

circuit

b)

equipment

c)

main

d)

appliance

6.

For a a one-family dwelling, at receptacle outlet is required in each _____.

a)

attached garage

b)

detached garage with power

c)

basement

d)

all of these least one

7.

Conductors supplying two or more motors shall have an ampacity equal to the sum of the full load current rating of all the motors plus ____% of the highest rated motor in the group.

a)

25

b)

100

c)

80

d)

125

8.

The MAXIMUM voltage allowed to supply listed electric-discharge lighting in residences, hotels, motels, and similar occupancies shall not exceed ______.

a)

230 volts

b)

208 volts

c)

240 volts

d)

277 volts

9.

A branch circuit that supplies two of receptacles or outlets for lighting more and appliances is a _____.

a)

individual

b)

multi-purpose

c)

general purpose

d)

utility

10.

If a conductor material is not specified in a particular Article or Section, the material shall be assumed to be which of the following?

a)

Copper

b)

Aluminum

c)

Copper-clad aluminum

d)

no assumptions shall be made

11.

A current limiting overcurrent protective device in the faulted circuit. is a device which will ____ the current flowing in the faulted circuit.

a)

reduce

b)

increase

c)

maintain

d)

none of these

12.

What rating of disconnecting means shall be used in a branch circuit containing 21.5 amperes?

a)

20 A

b)

25 A

c)

30 A

d)

40 A

13.

In any watercraft, receptacle outlets operating at ____ or more shall have a grounding pole.

a)

100 V

b)

120 V

c)

50 V

d)

60 V

14.

"Concealed" as applied to electrical wiring means, _______.

a)

rendered inaccessible by the structure

b)

capable of being removed without damage finish of the building

c)

capable of being reached quickly

d)

admitting close approach

15.

The grounded conductor at a service entrance shall not be smaller than the required size of the ________ conductor.

a)

phase

b)

service

c)

equipment

d)

grounding electrode

16.

Where a change occurs to the size of the ungrounded conductor, a similar change may be made in the size of the conductor.

a)

neutral

b)

grounding

c)

grounded

d)

none of these

17.

The circuit is that portion of a wiring system beyond the final overcurrent protection.

a)

lighting

b)

feeder

c)

signal

d)

branch

18.

Plug fuses must have what specific shape?

a)

octagonal

b)

Square

c)

hexagonal

d)

Round

19.

Branch circuit conductors supplying a single- phase motor shall have an ampacity NOT exceeding _____

a)

100%

b)

200%

c)

125 %

d)

115 %

20.

If the spring tension on a cartridge fuse clip is weak, the result most likely would be _____

a)

the fuse would blow immediately

b)

the fuse clips would become warm

c)

the voltage to the load would increase

d)

the supply voltage would increase

21.

Auxiliary gutters shall not contain more than ______ current carrying conductors at any cross section.

a)

36

b)

32

c)

30

d)

24

22.

The Code requires which of the following colors for the equipment grounding conductor?

a)

White or gray

b)

Green or green with yellow stripes

c)

Yellow

d)

Blue with a yellow stripe

23.

The grounding electrode shall be installed such that ____ mm of length is in contact with the soil

a)

1 800

b)

1 200

c)

1 500

d)

2 400

24.

A ____ shall be used to connect the grounding conductors, the service equipment enclosures, and equipment where the system is grounded, the grounded service conductor to the grounding electrode(s).

a)

busbar

b)

neutral conductor

c)

solid ground wire

d)

grounding electrode conductor

25.

Separation of junction box from motor shall be permitted to be separate from the motor not more

a)

6 feet (1.8 meters)

b)

4 feet (1.2 meters)

c)

8 feet (2.5 meters)

d)

none of these

26.

What is the MINIMUM size THW copper conductor that maybe used on a 30-A branch circuit?

a)

2.0 mm2 (No. 14 AWG)

b)

3.5 mm2 (No. 12 AWG)

c)

5.5 mm2 (No. 10 AWG)

d)

8.0 mm2 (No. 8 ANG)

27.

Concrete and brick walls are considered which of the following?

a)

Dry locations

b)

Wet locations

c)

Insulators

d)

Grounded

28.

Junction box shall be installed ______.

a)

accessible

b)

readily accessible

c)

visible

d)

all of these

29.

The definition of accessible (conductor) is_____

a)

admitting close approach

b)

not guarded by locked doors, elevation, and others

c)

not permanently closed in by the building or structure

d)

all of these

30.

The part of an electrical system that performs a mechanical function rather than an electrical function is called ________

a)

receptacle

b)

device

c)

fitting

d)

outlet

31.

The connection of a ground clamp to a grounding electrode shall be _________

a)

accessible

b)

visible

c)

readily accessible

d)

in sight

32.

A service disconnect means which of the following locations? shall be installed in

a)

Inside or outside of the building

b)

At nearest point of entrance to a structure

c)

Within 3 feet of the electrical panel

d)

all of these

33.

An enclosure either above or below ground, with resistant exclusively walls, ceiling and floor built for unattended transformers and their auxiliaries.

a)

Transformer housing

b)

Transformer yard

c)

Transformer vault

d)

none of these

34.

In dwelling units, at LEAST one wall receptacle outlet shall be installed in bathrooms within _____ mm of the outside edge of each basin.

a)

150

b)

900

c)

1 200

d)

450

35.

A separate portion of a conduit or tubing system that provides access through removable cover(s) to the interior of the system at junction of two or more sections of the system or at the terminal point of the system is defined as a _______.

a)

conduit body

b)

conduit junction

c)

conduit intersection

d)

conduit T-connector

36.

When the resistance-to-ground of a single ground rod exceeds 25 Q

a)

the ground rod must be removed

b)

no additional electrodes are required

c)

at least one additional electrode must be installed

d)

it must be connected to a PVC pipe at least 15 m in length

37.

Surge arresters grounding conductors shall NOT be run in metal enclosures unless of such enclosures.

a)

bonded to both ends

b)

bonded in one end

c)

bonded outside

d)

bonded inside

38.

In concealed knob and tube wiring the supports shall have at least ______ of each tap.

a)

125 mm

b)

100 mm

c)

150 mm

d)

170 mm

39.

What is the smallest size fixture wire allowed?

a)

2.0 mm2 (No. 14 AWG)

b)

1.25 mm2 (No. 16 AWG)

c)

0.75 mm2 (No. 18 AWG)

d)

0.51 mm2 (No. 20 AWG)

40.

Conduit installed in a concrete slab is considered a ______.

a)

damp location

b)

moist location

c)

wet location

d)

dry location

41.

Locknuts are sometimes used in making electrical connections on studs. In these cases, the purpose of the locknuts is to ________.

a)

to be able to connect several wires to one stud

b)

make it difficult to tamper with the connection

c)

make a tighter connection

d)

prevent the connection from loosening under vibration

42.

The Code rule for MAXIMUM 90-degree bends in a conduit between two boxes is the most likely reason for the total Four, 360-degree limitation is ______.

a)

it is unsafe

b)

it makes pulling the conductor through the conduit too difficult

c)

you can damage the galvanized coating on the conduit

d)

too many bends require extra wire to be pulled

43.

______ is defined as the shortest distance measured between a point on the top surface of any direct buried conductor, cable, conduit, raceway and the top surface of finished grade.

a)

Depth

b)

Cover

c)

Gap

d)

Soil

44.

A length of 50 feet wire has a resistance of 10 ohms. How much is the resistance of 25 feet its length.

a)

5

b)

3

c)

15

d)

75

45.

Corner joints on a gutter shall be made tight, where the assembly is held together by rivets or bolts. The spacing shall not be more than ________.

a)

250 mm

b)

100 mm

c)

300 mm

d)

200 mm

46.

A short length of a conductor used to make a connection between terminals or around a break in the circuit is a ______.

a)

jumper

b)

bonding wire

c)

tie wire

d)

guy wire

47.

Where conductors carrying alternating current are installed in metal enclosures or metal raceways, they shall be so arranged as to avoid heating the surrounding metal by induction, to accomplish this _____ shall be grouped together.

a)

all phase conductors

b)

where used, the grounded conductor

c)

all equipment grounding conductors

d)

all of these

48.

Type TW conductor is a ______ type.

a)

heat resistant and thermoplastic

b)

moisture and heat-resistant thermoplastic

c)

moisture and heat-resistant

d)

moisture resistant and thermoplastic

49.

The definition of ampacity is _______.

a)

the current-carrying capacity of conductors expressed in volt-amps

b)

the current-carrying capacity expressed in amperes

c)

the current-carrying capacity of conductors expressed in wattage

d)

the current in amperes a conductor can carry continuously under the conditions of use without exceeding its temperature rating

50.

__________ is a wiring method using knobs, tubes, and flexible non-metallic tubing for the protection and support of single insulated conductors concealed in hollow spaces of walls and ceilings of buildings.

a)

Knob and tube wiring

b)

Open wiring on insulators

c)

Open wiring with knobs, tubes, etc.

d)

Concealed knob and tube wiring

51.

Conductor sizes are expressed ______.

a)

only in circular mils

b)

In millimeter or in square millimeter

c)

in diameter or area

d)

in AWG or millimeters

52.

A fitting is ______.

a)

part of a wiring system that is intended primarily to perform an electrical function

b)

pulling cable into a confined area

c)

to be suitable or proper for

d)

part of a wiring system that is intended primarily to perform a mechanical function

53.

Nood used for decoration on a sign must not be closer to a lamp holder than ____.

a)

150 mm (6 inches)

b)

300 mm (12 inches)

c)

75 mm (3 inches)

d)

50 mm (2 inches)

54.

Comparing a 14 mm conductor to a 5.5 conductor of equal lengths, the 14 mm2 will have lower _____

a)

cost

b)

weight

c)

resistance

d)

strength

55.

The MINIMUM size of wire used in electrical wiring is the former number # 14 AWG. Under the metric system listed in the PEC, the diameter is _______.

a)

2.0 mm

b)

3.2 mm

c)

1.6 mm

d)

2.6 mm

56.

Type MI cable shall NOT be used ______.

a)

in dry, wet, or continuously moist location

b)

where exposed conditions to destructive corrosive

c)

for services, and feeders

d)

all of these

57.

A conductor encased within material of composition or thickness that is recognized by the PEC as electrical insulation is known as a/an ______.

a)

bare conductor

b)

a covered conductor

c)

concealed conductor

d)

an insulated conductor

58.

For screw shell devices with attached leads, the conductor attached to the screw shell shall be ____ in color.

a)

white or gray

b)

green

c)

orange

d)

black

59.

An assembly of two or more single-pole fuses is which of the following?

a)

Multiple fuse

b)

Multiple-tap conductor

c)

Switching device

d)

Panelboard

60.

The value of current, time, or both at which an adjustable circuit breaker is set to trip is known as ____.

a)

inverse time

b)

ampacity

c)

automatic

d)

setting

61.

______ any electric circuit that energizes signaling equipment.

a)

Low voltage circuit

b)

Signaling circuit

c)

Feeder

d)

Branch circuit

62.

What must the ampere rating be for a disconnecting means for a motor circuit rated 600 volts nominal, or less?

a)

100 of the motor nameplates current of the motor

b)

At Least 125 & of the full-load current rating of the motor

c)

At least 115 & of the full-load current rating

d)

At least 150 & of the full-load current rating of the motor

63.

______ lighting is a string of outdoor lights suspended between two points.

a)

Pole

b)

Equipment

c)

Festoon

d)

Outline

64.

An autotransformer must have a continuous neutral current rating, in a 4-wire system sufficient to handle _____.

a)

the minimum neutral unbalanced load

b)

the minimum neutral balanced load

c)

the maximum possible neutral unbalanced load

d)

the maximum neutral load in the system

65.

The PEC 1 2017 edition was referenced from the _____ edition of the National Electrical Code.

a)

2003

b)

2004

c)

2017 from the

d)

2006

66.

Use an approved ______ to protect conductors from abrasion where they enter a box.

a)

locknut

b)

all thread

c)

bushing

d)

insulator

67.

The MINIMUM headroom of working spaces service equipment and motor control for centers shall be at least _____.

a)

1 800 mm

b)

2 000 mm

c)

5 500 mm

d)

6 700 mm

68.

The name given to a system or circuit conductor that is intentionally grounded is ____.

a)

grounding conductor

b)

bonding conductor

c)

high-leg conductor

d)

grounded or neutral conductor

69.

The MAXIMUM size rigid metal conduit allowed for electrical construction is ____.

a)

100 mm

b)

150 mm (2009)

c)

155 mm (2017)

d)

300 mm

70.

Electric power is a measure of ____.

a)

work wasted

b)

electromotive force

c)

total work performed

d)

rate at which work is performed

71.

Raceways shall be provided with _____ to compensate for thermal expansion and contraction.

a)

accordion joints

b)

thermal clamps

c)

expansion joints

d)

thermal fittings

72.

The cross-sectional area of three or more THW conductors in a conduit must not exceed what percent of the cross-sectional area conduit?

a)

30 %

b)

40 %

c)

50 %

d)

60 %

73.

______ must not be allowed to come in contact with interior parts of electrical equipment.

a)

Insulators

b)

Busbars

c)

Terminals

d)

Abrasives

74.

If safety switches are horsepower rated; the rating must be marked on the switch as well as ______.

a)

Current and voltage rating

b)

voltage and wattage rating

c)

current and resistance rating

d)

voltage and resistance rating

75.

An unintentional, electrically conducting connection between an ungrounded conductor and normally non-current-carrying conductors, metallic enclosures, metallic raceways, metallic equipment, or earth, is called ____.

a)

arc fault

b)

stray current

c)

ground fault

d)

high impedance

76.

A circle with the letter B stands for _____.

a)

buzzer outlet

b)

pushbutton outlet

c)

outlet with blank cover

d)

bell outlet

77.

The PEC uses the term "isolated" to mean ____.

a)

not readily accessible to person unless special means for access are used

b)

grouped together

c)

identifiable by means of color coding or nameplate

d)

nearby conductors shall be used

78.

______ conductors shall be used for wiring on fixture chains and other moveable parts.

a)

Solid

b)

Covered

c)

Insulated

d)

Stranded

79.

When a fuse or circuit breaker is used for circuit protection, the fuse or overcurrent trip unit shall be connected _____.

a)

in series

b)

in series and parallel

c)

in parallel

d)

in tandem

80.

A compartment to which one or more air ducts are connected to form part of an air distribution system is called which of the following?

a)

Plenum chamber

b)

Air-flow box

c)

Ventilation duct

d)

Circulation cavity

81.

The conductors between the point of termination of the overhead service drop or underground service lateral and the main disconnecting device is in the building are known as _____.

a)

service disconnecting

b)

service conductors

c)

service drop

d)

service-entrance equipment

82.

Sometimes mercury toggle switches are used in place of a regular toggle switch because they _____.

a)

are easier to connect

b)

do not wear out as quickly

c)

are less expensive

d)

they glow in the dark

83.

When circuit breakers are installed in enclosed switchboards, they are usually derated to a certain percentage. What is this percentage?

a)

60 %

b)

80 %

c)

50 %

d)

70 %

84.

Capable of being inadvertently touched or approached nearer than a safe distance by a person. It is applied to parts that are not suitably guarded, isolated, or insulated.

a)

Isolating switch

b)

By-pass isolation switch

c)

Exposed (as applied to wiring methods)

d)

Transfer switch

85.

What is the diameter of a solid wire, which is equivalent to 5.5 mm2?

a)

2.26 mm

b)

1.62 mm

c)

1.75 mm

d)

2.65 mm

86.

The demand factor of any electrical system is the ratio of the MAXIMUM demand for a system to _______.

a)

the total connected load of the system

b)

125 percent of the total connected load of the system

c)

125 percent of the total connected continuous load of the system

d)

80 percent the total connected the noncontinuous load plus 125 percent total connected continuous load of the system

87.

The rating of the overcurrent protective device circuit supplying hermetic motor-compressor must be at least ______ of the nameplate rated load current.

a)

80%

b)

155%

c)

125%

d)

135%

88.

A dry type of transformer not rated over 112 1/2 kVA installed indoors, shall have a separation of at least ______ from combustible material.

a)

600 mm

b)

450 mm

c)

300 mm

d)

900 mm

89.

When using a phase converter for a fixed load, the single-phase conductors must have an ampacity not less than what percentage of the full-load current rating of the motor or other load being served where the input and output voltages are the same ______.

a)

300%

b)

250 %

c)

150%

d)

175 %

90.

The Code requires all circuits to have _____ and adequate grounding.

a)

at least two wires

b)

outlets

c)

breakers

d)

lightings

91.

The branch-circuit loads specified by the Code for lighting and receptacles are considered _____.

a)

minimum loads

b)

maximum loads

c)

loads to be served

d)

peak loads

92.

A location classified as _______ may be temporarily subject to dampness and wetness.

a)

dry

b)

damp

c)

moist

d)

wet

93.

The service conductors between the terminals of the service equipment and a point usually outside the building, clear of building walls, where joined by tap or splice to the service drop is called the ____.

a)

service drop

b)

service-entrance conductors

c)

service equipment

d)

none of these

94.

Screw-shell lamp holders shall be wired so that the _______ conductor is connected to the screw-shell.

a)

bare

b)

ungrounded

c)

grounded

d)

grounding

95.

A single receptacle on an individual branch circuit shall have a MINIMUM rating of what percentage of the branch circuit's rating?

a)

50%

b)

70 %

c)

80%

d)

100 %

96.

A pool recirculating pump motor receptacle shall be permitted not less than ____ mm from the inside walls of the pool.

a)

1 500

b)

3 000

c)

2 300

d)

3 600

97.

Operation at a substantially constant load for an indefinitely long time.

a)

Periodic duty

b)

Continuous duty

c)

Intermittent duty

d)

Short time duty

98.

In concealed knob and tube wiring, the clearance to be maintained between conductors is ______.

a)

55 mm

b)

45 mm

c)

75 mm

d)

50 mm

99.

Electrical parts that are not suitably guarded, isolated, or insulated and are capable of being inadvertently touched or approached near than a safe distance by a person is known as ______.

a)

dead front

b)

exposed

c)

externally operable

d)

accessible

100.

Concealed knob and tube wiring conductors shall be rigidly supported on knobs not more than a certain minimum distance apart. What is this distance?

a)

2 000 mm

b)

1 500 mm

c)

1 400 mm

d)

2 500 mm