Font size
WorksheetsChapter 4: Construction Types and Occupancy Classifications
Total questions: 97
Worksheet time: 51mins
Which construction type?
Type I
Type II
Type III
Type IV
Which construction type?
Type I
Type II
Type III
Type IV
Which construction type?
Type I
Type V
Type III
Type IV
Which construction type?
Type I
Type V
Type III
Type IV
Which construction type?
Type I
Type II
Type III
Type IV
Which construction type?
Type I
Type II
Type IV
Type V
Which construction type?
Type I
Type II
Type III
Type V
Which construction type?
Type I
Type II
Type III
Type IV
Which construction type?
Type I
Type II
Type III
Type V
Which construction type?
Type II
Type III
Type IV
Type V
Which construction type?
Type I
Type IV
Type III
Type V
Which construction type?
Type I
Type III
Type IV
Type V
Which construction type?
Type I
Type II
Type IV
Type III
Which construction type?
Type I
Type II
Type IV
Type V
Which construction type?
Type I
Type II
Type III
Type IV
What building codes establish construction types and occupancy classifications?
Codes adopted by the AHJ
Codes adopted by City Marshall
Codes adopted by the government
Codes adopted by the state
What is required in US construction? Select all that applies.
Load-bearing walls
Non-load bearing walls
Floor Construction
Roof construction
Plumbing
In Type I construction, all structural members are composed of only __________ materials that possess a high-resistance rating.
high-quality
noncombustible
combustible
nonflammable
Reinforced and precast concrete, masonry, and protected steel-frame construction meets the criteria for _____ construction
Type I
Type II
Type III
Type IV
What is this an example of?
Hint: Only found in Type I construction
Protected-steel
Nonprotected Steel
Exterior Roof
Dirty Ceiling
Who determines the type of construction used in building or remodeling?
The architect or design professional
The building workers
City Marshall
Fire Inspector
What are walls of a building that carry the structural load of the building in the direction of the ground or base?
Load-bearing walls
Nonload-bearing walls
Decorative walls
Fire-resistant walls
What are walls that can be breached or removed without compromising the structural integrity of the building?
Load-bearing walls
Nonload-bearing walls
Decorative walls
Fire-resistant walls
True or false:
Type I construction are referred to as fireproof.
True
False
True or false:
Specific combustible materials in small quantities are occasionally allowed in Type I construction if stated in model codes.
Hint: Look at page 120
True
False
Which type of buildings are composed of noncombustible materials that do not meet the stricter requirements and are considered to be a low fire-risk?
Type I
Type II
Type IV
Type V
Which are factors for building construction? Select all that apply.
Occupancy type
Building Size
Automatic Suppression System
Construction Materials
Cost
True or False:
Every structure is composed of load-bearing walls, non-load bearing walls, structural frame, floor construction, and roof construction.
True
False
Which type of construction has the highest fire-resistance?
Type I
Type II
Type III
Type IV
When protected steel is exposed to fire, the steel ________. The "fuzzy carpet" protects the steel from failing.
expands
bends
breaks
melts
Which construction type is built with passive agents?
(things that will not contribute to fire development)
Type I
Type II
Type III
Type IV
Which type of occupancies have low fire risk? Select all that apply.
Business
Education
Assembly
Storage
True or false:
Type II constructed has protected steel.
True
False
Select examples of Type III construction types.
Churches
Schools
Apartments
Mercantile structures
Hospitals
Why do we have fire-stopping in Type III construction?
To help prevent the spread of fire in void spaces
To comply with federal codes
To have fire-resistant construction
Are there concealed places in Type IV construction?
Yes, it prevents fire spreading.
No, it is a fire hazard.
It depends on the codes.
Type V is known as _________ construction.
Wood frame
Masonry
Protected-Steel
Heavy-timber
Which type of construction have exterior bearing walls that may be composed of wood and other combustible materials?
Type I
Type II
Type IV
Type V
What is a wooden structural panel formed by gluing and compressing wood strands together under pressure?
Oriented strand board (OSB)
Rigid insulation boards
Glue-laminated beam
Nonload-bearing walls
What are the benefits of lightweight wood truss?
Assembled in many configurations
Supports large loads over long spans
Efficient use of lumber
Structural redundancy is reduced
Occupancy classifications are established because certain occupancies have higher _______ and greater numbers of occupants.
Fire load
Combustion point
Model codes
Permits
Which occupancy is a structure or compartment that is used for the gathering of 50 or more persons?
Assembly
Educational
Storage
Institutional
Which occupancy provides a working place for large numbers of occupants in an office environment?
Assembly
Mercantile
Educational
Business
What are the benefits of wood I-joists? Select all that apply.
Cost-effective
Efficient at spanning large distances
Susceptible to fire damage
Easier to build
True or false:
An occupancy classification can be defined as the use of all or a portion of a building structure.
True
False
Model code organizations have developed classifications that separate each occupancy into _____ categories based on the use of the structure and space.
risk
building
construction
fire
I have an occupant load of 49. What is my occupancy classification?
Business
Assembly
Institution
Storage
Select the examples of business occupancies.
Select all that apply.
Medical offices
Air traffic control towers
Municipal buildings
Barber and beauty shops
Daycare
Healthcare occupancies and residential care occupancies have ____ or more residents.
4
10
50
15
The evacuation capabilities of a residential board and care occupancy must be properly classified as ________, ________, or _______.
slow, prompt, or impractical
fast, quick, or practical
expensive, safe, or dangerous
swift, protected, or impractical
The occupancy as a whole must be classified based on the resident posing the most significant ______.
threat
risk
support
health issues
What are examples of one and two family dwellings? Select all that applies.
Detached units
Semidetached units
Duplexes
Dormitories
Lodging houses
True or False:
If you are in a more economically advantaged area, your fire risk will more than likely be higher.
True
False
Which is NOT an example of incidental use?
(Per the book)
Furnace room
Parking Garages
Incinerator Rooms
Bathroom
Waste and Linen Collection Rooms
Doors leading into these areas must be ______ or the automatic-closing type that closes in incidental use.
Self-closing
Self-cleaning
Self-operating
Self-heating
What is it called when each structure is individually classified by its primary occupancy classification and separated from the other occupancies by the appropriate fire wall separation?
Mixed-Use
Incidental Use
Accessory
Nonseparated
Each of the model code organizations have developed occupancy ___________ that clearly separate each occupancy into categories of risk based upon the use of the structure or space.
classifications
amendments
comparisons
standards
In Type I construction, all structural members possess a _____ fire-resistance rating.
partial
medium
high
low
A commercial printing operation that has paper storage is an example of what type of challenge for an inspector?
A facility with different uses under one roof
A facility with low fire load
A facility with intermingled uses
A facility with a large number of workers
Medical offices are considered _____ occupancies.
Business
Mercantile
Institutional
Assembly
Nonseparated occupancies are buildings or portions of buildings that have _____ occupancy use(s).
at least one
two or more
limited
zero
Type II construction is normally used when______________
the structure is located near a fire station
water is readily available
fire risk is low
small quantities of combustible materials are used
What can reduce the fire-resistance rating requirements for mixed-use occupancies?
Automatic fire suppression systems
Fewer people present
Nothing can reduce the rating requirements
Distance from a fire department
Which of the following is an example of a common Type III structure?
Single-family homes
Warehouses
Barns
Apartment buildings
A duplex would be classified as _____ by NFPA
a hotel or motel
a lodging or rooming house
.
a dormitory
a one- and two-family dwelling
Which is one of the uses of an educational facility?
Display and sale of merchandise
Food preparation
Storage and sheltering of goods
Detention facilities
A(n) ________ occupancy is subsidiary to the main occupancy and limited to no more than 10 percent of the area of the story on which they are located.
High hazard
Accessory
Nonseparated
Separated
Factory and industrial occupancies are broken down into subdivisions based on:
construction materials
hours of operation
purposes and hazards
number of occupants
The National Fire Protection Association® (NFPA®) is an example of a third-party organization that develops
model codes
review plans
state laws
industry standards
A ________ is an example of an institutional occupancy
municipal buildings
university facility
church building
correctional facility
According to NFPA 101, a hotel is a building or buildings that has sleeping for more than __________ people and is primarily used by transients for lodging
16
18
14
10
Generally, ___________ are those structures that provide sleeping accommodations under conditions other than those defined for health care or detention and correctional occupancies.
institutional occupancies
high-rise occupancies
residential occupancies
mid-rise occupancies
Entire structures or portions of structures that have several occupancy types contained with them are referred to as_______
Separated occupancies
Nonseparated occupancies
Accessory occupancies
Incidental occupancies
Fences over 6 feet in height, towers, carports, and retaining walls are classified as:
Utility / Misc Use
Storage
Institutional
Education
Which examples are classified as storage?
Select all that apply
Sheds
Barns (with something living)
Aircraft hangers
Parking garages
Grain elevators
True or false:
In general, NFPA101 requires the separation of occupancies in the same structure.
True
False
Occupancies that are used to store goods, merchandise, vehicles, or animals are referred to as what kind of occupancy?
Storage
Utility
Business
Mercantile
Apartment units may be single or multistory structures containing ______ or more independent dwelling units equipped with cooking and bathroom facilities.
3
12
6
16
Per the book, apartment buildings that are greater than ______ stories may be considered high-rise structures that require higher levels of fire and life safety protection.
7
10
4
5
According to the ICC, fraternity and sorority houses fall under this residential category:
Hotel
Boarding house
Dormitory
Apartment building
Why should lodging or rooming houses have additional signage and maps exit paths?
To increase safety since occupants are unfamiliar with surroundings
For the occupancy to follow the ICC
To make the occupancy look more official
To provide better sleep accommodations
A pharmacy is considered a _______ occupancy.
Mercantile
Business
Industrial
Assembly
Daycares with children 2 1/2 years of age and under fall under the ______ classification.
Education
Institutional
Business
Mercantile
What is the classification of colleges and university buildings?
Educational
Institutional
Business
Mercantile
Sheathing for Type V construction may include any of the following.
Select all that applies.
Wooden boards
Plywood
Oriented strand board (OSB)
Rigid insulation boards
Gypsum
A building’s construction is based on:
Select all that applies.
Fire resistance of the materials
Design of the structure
The use of the structure
The cost of the structure
The buildings’s occupancy
True or false:
Type I structures are fire-proof.
True
False
Brick, concrete, and reinforced concrete are typical materials used in exterior walls and interior no bearing walls this type of construction.
Type I
Type II
Type III
Type V
Voids exist inside the wooden channels created by the roof and truss systems will allow fire to spread unless proper _______ is applied.
Oriented stand board
Fire-stopping
Glued laminated beams
Timber
What are some disadvantages of wood I-joists?
They’re light and susceptible to fire damage.
Structural redundancy is reduced.
They are expensive and difficult to install.
They have to be approved by model codes first.
Trusses typically use a ______ configuration to provide stability and efficiently transfer the applied loads.
Triangular
Circular
Perpendicular
Vertical
Gymnasiums, lecture halls, and dining halls follow the requirements for ______ occupancies.
Assembly
Business
Institutional
Residential
A bowling alley has a _______ classification.
Assembly
Business
Residential
Institutional
What are buildings in which people with physical limitations due to health or cared for by provided medical treatment?
Institutional occupancies
Business occupancies
Residential occupancies
Industrial occupancies
A detention center or correctional facility is considered what kind of occupancy?
Institutional
Educational
Residential
Industrial
Bed and breakfasts are classified as _______.
Residential
Institutional
Assembly
Mercantile
A parking garage is classified as _____.
Storage
Utility
Assembly
Institutional