Food waste disposers shall be provided with a supply of cold water and protected against backflow by an ____ _____
air gap
check valve
pressure regulator
drain trap
Drinking fountains shall not be required to be located in individual tenant spaces provided that public drinking fountains are located with a travel distance of __________ feet of the most remote location in the tenant space.
500
100
250
1000
In employee and public toilet rooms, the required lavatory shall be located in the same _______ as the required water closet.
room
building
floor
hallway
Separate toilet facilities are not required in structures or tenant spaces with a total occupant load of ______ or fewer.
15
10
20
25
The water-temperature-limiting device required by this section shall be equipped with a means to limit the maximum setting of the device to ______ and, where adjustable, shall be field adjusted in accordance with the manufacturer's instructions to provide hot water at a temperature not to exceed _______.
120, 120
110, 120
130, 120
140, 130
Urinal partitions shall begin at a height not greater than ______ inches from and extend not less than _____ inches above the finished floor surface.
12, 60
18, 48
24, 54
10, 42
All shower compartments shall be not less than _____ square inches in interior cross-sectional area with a least dimension not less than _____ inches.
900, 30
1000, 32
800, 28
950, 36
Sinks shall be provided with waste outlets a minimum of _______ inches in diameter.
1 ½
1
2
2 ½
Restaurants shall have a minimum of 1 lavatory for each ______ persons.
200
100
300
500
The waste connection of a residential dishwasher is permitted to connect directly to a __________ __________ on the tailpiece of the kitchen sink or the dishwasher connection of a __________ __________ ____________.
wye branch fitting, food waste disposer
trap adapter, double sanitary tee
cleanout plug, vent stack
drain cap, air admittance valve
Plumbing fixtures shall be installed so as to afford easy access for ____________ both the fixture and the area around the fixture.
cleaning
painting
decorating
repairing
In each bathroom or toilet room, urinals shall not be substituted for more than _______ percent of the required water closets in assembly and educational occupancies.
67
25
50
75
A water closet, urinal, lavatory or bidet shall not be set closer than __________ inches from its center to any sidewall, partition, vanity or other obstruction.
15
10
18
12
____________ water shall be delivered from lavatories and group wash fixtures located in public toilet facilities.
tempered
cold
distilled
softened
There shall not be less than ____________- inch clearance in front of the water closet, urinal, lavatory or bidet to any wall, fixture or door.
21
15
18
24
Drinking fountains, water coolers and water dispensers shall not be installed in public ____________.
restrooms
libraries
parks
lobbies
Wall and floor space to a point 2 feet in front of a urinal lip and _______ feet above the floor and at least _______ feet to each side of the urinal shall be waterproofed.
4, 2
3, 1
5, 3
2, 1
Bathtubs shall be equipped with a waste outlet that is not less than ______ inches in diameter.
1 ½
1
2
2 ½
In what occupancies do you need to provide toilet facilities for employees?
all occupancies
only residential occupancies
only commercial occupancies
only industrial occupancies
Where separate toilet facilities are required for each sex and each toilet facility is required to have only one water closet, two ____________ or ____________ - ____________ toilet facilities shall be permitted to serve as the required separate facilities.
family, assisted-use
public, private-use
employee, customer-use
male, female-only
Domestic food waste disposers shall be connected to a drain of not less than _______ inches in diameter.
1 ½
1
2
2 ½
Determining the occupant load for each sex when calculating how many plumbing fixtures are required involves:
Dividing the total occupant load equally between males and females unless otherwise specified.
Assigning all occupants to one sex based on building use.
Using only the number of employees for calculation.
Estimating based on the number of restrooms available.
Water closet bowls for public or employee toilet facilities shall be of the _________ type.
elongated
round
square
compact
The wall area of showers and above built-in tubs with installed shower heads shall be constructed of smooth, corrosive-resistant and nonabsorbent waterproof materials to a height not less than ________ feet above the room floor level.
6
4
5
7
Whirlpool bathtub pumps shall be located ______ the weir of the fixture trap.
above
below
beside
inside
Public toilet facilities shall not be required in structures and tenant spaces intended for ______________ transactions having a public access area less than or equal to ________ square feet.
quick, 300
retail, 500
office, 200
food, 1000
Where drinking fountains are required in occupancies other than a restaurant where three or more drinking fountains are required, water dispensers shall be permitted to be substituted for not more than __________ percent of the required number of drinking fountains.
50
25
75
100
Urinal partitions shall extend from the wall surface at each side of the urinal not less than ______ inches or to a point not less than ______ inches beyond the outermost front lip of the urinal, whichever is greater.
18, 6
12, 4
24, 8
15, 5
Whirlpool bathtub pumps shall be located above the __________ of the fixture trap.
weir
rim
base
center
Water closet compartments shall be not less than __________ inches in width and not less than ______ inches in depth for floor-mounted water closets.
30, 60
28, 54
32, 48
36, 72
Commercial food waste disposer shall be listed in accordance with ______.
UL 430
UL 489
UL 197
UL 943