WorksheetsKSS AIR
Total questions: 20
Worksheet time: 10mins
Bulk CR is applicable if it has minimum __ quantity
20
30
25
35
Select the correct PSIS code for rotary cryo-2 test
PSIS-114
PSIS-115
PSIS-116
PSIS-117
Which order is right for liquid penetrant test?
Penetrant apply, development, inspection, surface preparation
Surface preparation, penetrant apply, development, inspection
Penetrant apply, development, surface preparation, inspection
Development, surface preparation, penetrant apply, inspection
Expansion of CESR
Customized Engineered Solutions Request
Customized Engineering Solutions Request
Custom Engineering Solutions Request
Custom Engineered Solutions Request
What is the minimum port size available for a balanced cryogenic construction?
3 7/16"
4 3/8"
2 5/16"
2 7/8"
A valve item is built and awaiting FAT. How to calculate CR charges for a fisher actuator model change (from 657 to 667) for the item.
$450+ 20% of actuator price
$450+ 30% of actuator price
$450+ 40% of actuator price
$450+ 35% of actuator price
Which assembly document is used in assembling A31A Cryo NPS 3 – NPS 12
FGS 12B29
FGS 12B12
FGS 12B19
FGS 18B25
In which type of test the capillary action principle is used?
Probe test
Bend liquid test
Dye penetrant test
None of the above
Expansion of ENFPI
European Non Fisher Publicized Items
European Non Fisher Published Items
European Non Fisher Publicized Instruments
European Non Fisher Published Instruments
What is used as the source of rays for radiography?
Uranium-235
Tellurium
Cobalt-60
Manganese dioxide
Expansion of DDP
Delivery Duty Pending
Delivered Duty Paid
Direct Delivery Payment
Despatched Delivery Priority
Which test is used to determine dimensions of any object?
Ultrasonic test
Torsion test
Eddy current test
All of these tests can be used to determine dimensions of any object
Expansion of ATEX
Above Threshold Explosion Design
Atmosphères Explosibles
Automated Thermal Explosion Control
Advanced Technical Explosive Standards
Which line should be used in FF2 to capture expediting charge.
9800
9900
9200
9400
In cryogenic class A, Maximum permissible seat leakage shall not exceed -------- of the rated valve capacity
0.0105%
0.0002%
0.0005%
0.00005%
Expansion of SMAW
Submerged Metal Arc Welding
Shielded Metal Arc Welding
Sequential Metal Arc Welding
Structured Manual Arc Welding
During radiography test, which region absorbs less radiation and transmits more?
Low and high density regions absorb and transmit same amount of radiation
High density region
Low density region
None of the above
Which seal is required to achieve CL VI CRYO B IN A11 valve
NOVEX
CTFE w/ Backup Ring
HPS
metal seal
What is the primary function of an Anti Surge valve in a compressor system?
To increase compressor speed
To reduce discharge pressure
To prevent surge by maintaining minimum flow
To cool the compressor
What component is used to rapidly relieve surge conditions in a compressor?
Trip Valve
Volume Booster
Anti Surge Valve
Check Valve