NEW
Font size
WorksheetsAPRACN01_LONG QUIZ
Total questions: 50
Worksheet time: 25mins
Minimum door width for hospital nursing units?
1.20 meters
0.80 meters
1.10 meters
0.90 meters
What general conditions of design are important for the aged?
Size, location, design
Grab Bar
Height of lavatory is from the waist
All of the above
What is Central Refuge?
Home for the homeless disabled person
Space for wheelchair when passing through a road
Center for disabled person
Pedestrian way for disable only
What should be provided in the immediate vicinity of crossings as an aid to the blind?
Tactile surface
Pavers with slot openings
Planters and landscapes
0.30 m kick plates
What is the minimum depth of a Central Refuge?
1.20 m
2.0 m
1.50 m
1.80 m
From BP 344, what is the maximum width of a carriageway where a central refuge is no longer required?
4 m
6 m
8 m
10 m
Dropped curbs at crossings have a width corresponding to the width of the crossing; otherwise, the minimum width is?
0.80 m
0.90 m
1.0 m
1.20 m
Dropped curbs shall be ramped towards adjoining curbs with a gradient not more than?
1:12
1:6
1:20
1:30
The lowest point of a dropped curb from the road or gutter should not exceed?
10 mm
15 mm
20 mm
25 mm
The minimum width of a curb cut-out?
0.80 m
0.90 m
1.00 m
1.20 m
Walkways should have a continuing surface without abrupt pitches in angle or interruptions by cracks or breaks creating edges above?
3 mm
6.5 mm
6 mm
2.5 mm
In lengthy or busy walkways, spaces should be provided at some point along the route so that a wheelchair may pass another or turn around. These spaces should have a minimum dimension of 1.5 m and should be spaced at a maximum distance of?
12 m between stops
6 m between stops
10 m between stops
15 m between stops
To guide the blind, walkways should as much as possible follow straightforward routes in?
45-degree angle
Right angle
Perfect rounded curve
Chamfered corner with metal gratings
Walkway headroom is preferably higher and should not be less than?
2.40 m
2.10 m
2.00 m
2.70 m
Handrails for protection at great heights may be installed?
1 m to 1.06 m
0.90 m to 1.20 m
0.90 m to 1.10 m
1.05 m to 1.15 m
Deal extension of the handrail should be provided at the start and end of ramps and stairs of about?
500mm
400mm
300mm
250mm
Handrails that require full grip should have a dimension of?
30 to 60mm
30 to 50mm
25 to 50mm
40 to 60mm
Handrails “attached to walls” should have a clearance from the wall of no less than?
35mm
40mm
50mm
60mm
Handrails on ledges should have a clearance not less than?
35mm
40mm
50mm
60mm
Signs on walls and doors should be located at a maximum height of?
1. 60 m
2.10 m
1.20 m
1.40 m
Signage labeling public rooms and places should have raised symbols, letters or numbers with minimum height of?
1 mm
2 mm
3 mm
6.5 mm
Minimum central refuges, where the width of the carriageway to be crossed exceeds 10m?
1.5 m in depth
2.0 m in depth
1.80 m in depth
1.20 m in depth
The flashing green period required for the disabled should be determined on the basis of a walking speed of?
0.90m/ sec
1.20m/ sec
0.80m/ sec
0.75m/ sec
The minimum period for the steady green (for pedestrians) should not be less than?
12 secs
10 secs
8 secs
6 secs
Accessible parking slots should have a minimum width of?
2.40 m
3.00 m
2.50 m
none
One community facility will be provided for housing projects and will be mandatory for how much in hectares?
1 and above
2 and above
3 and above
4 and above
A building designed or used as a residence for one or more families.
Dwelling
Facilities
Parks
Multi-purpose center
A dwelling for one family that is surrounded by permanent spaces with independent access, services, and use of land.
Single-family detached
single-family attached
rowhouses
townhouses
A dwelling on one lot containing separate living units for 3 or more families, usually provided with common access, services and use of land.
single-family detached
multi-family dwelling
rowhouses
multi-purpose dwelling
A parcel of land bounded on the sides by streets or alleys or pathways or other natural or manmade features, and occupied by or intended for buildings.
Block
Plot
Parcel
Unit
A public way intended for pedestrian and which cuts across a block to provide access to adjacent streets or property with maximum length of 100 meters if connecting to roads and 50 meters if terminating in a dead end.
Pathwalk/ footpath
RROW
Alley
Abutment
A public way intended to serve both pedestrian and emergency vehicles, and also provide access to lots, both end always connecting streets.
Pathwalk/footpath
RROW
Alley
Street
A single-family dwelling containing three or more separate living units grouped closely together to form relatively compact structures.
Rowhouses
Cluster housing
Apartment
Duplexes
A wall used jointly by two parties under an easement agreement, erected upon a line separating two parcels of land, each of which is a separate real estate.
Firewall
Party wall
Fire block
Blank wall
As per BP 220, windows that will be used for baths or toilets will be how many percent at least, of the floor area of the room.
10%
5%
15%
4%
As per BP 220 windows that will be used for rooms or any habitation will be how many percent at least, of the floor area of the room.
10%
5%
15%
4%
For a circular staircase, what will be the minimum run in the narrower end of the step?
250mm
200mm
350mm
300mm
For habitable rooms the height of floor to ceiling is?
2.70 m
2.40 m
2.10 m
2.00 m
For inner courts, a passage way must be provided with a minimum width of.
1.20 m
2.0 m
1.80 m
3.0 m
For single family dwellings, all yards must have at least_____m horizontal dimension.
1.50 m
2.00 m
3.00 m
4.00 m
Who signed Executive Order No. 278 into law?
Fidel V. Ramos
Benigno S. Aquino III
Gloria Macapagal-Arroyo
Rodrigo Duterte
When was E0 278 officially signed?
January 15, 2002
February 2, 2004
March 22, 2003
April 5, 2001
EO 278 primarily aims to promote which of the following principles?
Equal opportunity for ASEAN architects
Preference for qualified Filipino professionals in foreign-assisted projects
Exclusive participation of international consultants
Automatic funding for all public infrastructure projects
Under EO 278, consultancy services shall be proposed for foreign assistance only when:
The project is under ASEAN funding
Foreign consultants request participation
Local funds are insufficient or foreign expertise is indespensable
The local contractor declines participation
The general policy on consultancy services under EO 278 requires that:
All consultancy projects must be foreign-funded
Consultancy services be funded with local funds whenever possible
Foreign firms be prioritized in project packaging
Only ASEAN firms can participate in consultancy
In multi family dwellings, buildings with 2 storey how much in meters must be the 2 structure apart in distance.
4 meters in between
3 meters in between
5 meters in bewteen
2 meters in between
In multi family dwellings, buildings with 3-4 storey how much in meters must be the 2 structure apart in distance.
4 meters in between
5 meters in between
6 meters in between
7 meters in between
In multi family dwellings, buildings with 3-4 storey how much in meters must be the 2 structure eaves apart in distance
4 meters between eaves
3 meters between eaves
2 meters between eaves
1 meter between eaves
In multi family dwellings, buildings with 4 storey above how much in meters must be the 2 structure eaves apart in distance
7 meters between eaves
6 meters between eaves
5 meters between eaves
4 meters between eaves
In multi family dwellings, buildings with 4 storey above how much in meters must be the 2 structure apart in distance
12 meters in between
10 meters in between
8 meters in between
6 meters in between
