In KMBR, if the width of an abutting road is 10 m and front yard width is 3 m, the maximum permissible building height will be –
20 m
23 m
26 m
30 m
When actual cantilever projection of a chajja exceeds the permissible limit under bye-laws, the most likely violation is of –
Structural stability
Building height restriction
Setback regulation
Floor area ratio
A semi-detached building must have a minimum plot frontage of 12 m as per NBC. If the frontage is 10 m, such a building shall be classified as –
Detached
Row or Group housing
Special building
Multi-storeyed building
The fire load of a building depends primarily upon –
Quantity and calorific value of combustibles
Type of ventilation openings
Fire resistance of walls
Number of storeys only
The ratio of horizontal circulation area to plinth area is generally taken as –
2–3% for industrial buildings
4–5% for residential buildings
8–10% for assembly buildings
10–12% for public buildings
TRUE / FALSE
In a corner plot with two abutting streets, the larger setback distance shall be provided on the side of the narrower street.
(a)
TRUE/FALSE
According to NBC, a Mumty is a cabin-like structure provided over a staircase for headroom and roof access.
(a)
Assertion (A): The setback line is fixed to ensure adequate light and ventilation. Reason (R): Setback lines are governed only by the owner’s choice and not by any regulation.
Both A and R are true, and R is the correct explanation
Both A and R are true, but R is not the correct explanation
A is true but R is false
Both A and R are false
As per NBC, the minimum clear height of a habitable room shall not be less than (a) m.
In load bearing construction, the wall thickness increases with the (a) of the building.
The full form of KMBR is (a) .
As per KMBR, the minimum open space on each side of a detached residential building shall not be less than (a) m.
The maximum plot coverage permitted for residential buildings under Group A1 occupancy is generally (a) %.
MATCH THE FOLLOWING
A. Chajja - Cabin structure over stair
B. Mumty - Sunshade over openings
C. Barsati - Roof shelter for outdoor waiting
D. Canopy - Small living enclosure on terrace
A – 1
B – 2
C – 4
D – 3
A – 2
B – 4
C – 1
D – 3
A – 2
B – 1
C – 4
D – 3
A – 2
B – 1
C – 3
D – 4
MATCH THE FOLLOWING
A. Kitchen with separate dining - 9.5 m²
B. Bath + WC - 1.5 m²
C. Bath only - 2.25 m²
D. Water closet - 2.8 m²
A – 1
B – 3
C – 2
D – 4
A – 1
B – 4
C – 3
D – 2
A – 3
B – 1
C – 4
D – 2
A – 1
B – 3
C – 4
D – 2