wayground logo

Free Printable Worksheets

Font size

S
M
L
XL
Worksheets

DAY 41 WORKSHEET ITI (Building Rules & Byelaws)

Total questions: 15

Worksheet time: 9mins

Name
Class
Date
1.

In KMBR, if the width of an abutting road is 10 m and front yard width is 3 m, the maximum permissible building height will be –

a)

20 m

b)

23 m

c)

26 m

d)

30 m

2.

When actual cantilever projection of a chajja exceeds the permissible limit under bye-laws, the most likely violation is of –

a)

Structural stability

b)

Building height restriction

c)

Setback regulation

d)

Floor area ratio

3.

A semi-detached building must have a minimum plot frontage of 12 m as per NBC. If the frontage is 10 m, such a building shall be classified as –

a)

Detached

b)

Row or Group housing

c)

Special building

d)

Multi-storeyed building

4.

The fire load of a building depends primarily upon –

a)

Quantity and calorific value of combustibles

b)

Type of ventilation openings

c)

Fire resistance of walls

d)

Number of storeys only

5.

The ratio of horizontal circulation area to plinth area is generally taken as –

a)

2–3% for industrial buildings

b)

4–5% for residential buildings

c)

8–10% for assembly buildings

d)

10–12% for public buildings

6.

TRUE / FALSE

In a corner plot with two abutting streets, the larger setback distance shall be provided on the side of the narrower street.

(a)  

7.

TRUE/FALSE

According to NBC, a Mumty is a cabin-like structure provided over a staircase for headroom and roof access.

(a)  

8.

Assertion (A): The setback line is fixed to ensure adequate light and ventilation. Reason (R): Setback lines are governed only by the owner’s choice and not by any regulation.

a)

Both A and R are true, and R is the correct explanation

b)

Both A and R are true, but R is not the correct explanation

c)

A is true but R is false

d)

Both A and R are false

9.

As per NBC, the minimum clear height of a habitable room shall not be less than (a)   m.

10.

In load bearing construction, the wall thickness increases with the (a)   of the building.

11.

The full form of KMBR is (a)   .

12.

As per KMBR, the minimum open space on each side of a detached residential building shall not be less than (a)   m.

13.

The maximum plot coverage permitted for residential buildings under Group A1 occupancy is generally (a)   %.

14.

MATCH THE FOLLOWING
A. Chajja - Cabin structure over stair

B. Mumty - Sunshade over openings
C. Barsati - Roof shelter for outdoor waiting
D. Canopy - Small living enclosure on terrace

a)

A – 1
B – 2
C – 4
D – 3

b)

A – 2
B – 4
C – 1
D – 3

c)

A – 2
B – 1
C – 4
D – 3

d)

A – 2
B – 1
C – 3
D – 4

15.

MATCH THE FOLLOWING
A. Kitchen with separate dining - 9.5 m²
B. Bath + WC - 1.5 m²
C. Bath only - 2.25 m²
D. Water closet - 2.8 m²


a)

A – 1
B – 3
C – 2
D – 4

b)

A – 1
B – 4
C – 3
D – 2

c)

A – 3
B – 1
C – 4
D – 2

d)

A – 1
B – 3
C – 4
D – 2