wayground logo

Free Printable Worksheets

Font size

S
M
L
XL
Worksheets

DAY 42 WORKSHEET ITI - (Building Planning and Design )

Total questions: 15

Worksheet time: 9mins

Name
Class
Date
1.

A site plan as per KMBR must be drawn to a minimum scale of 1:400, whereas as per NBC the corresponding minimum scale is —

a)

1:1000

b)

1:800

c)

1:500 (for ≤1 ha)

d)

1:10,000

2.

A building facing two intersecting streets has unequal widths. Its permissible height will be based on —

a)

The average of both streets

b)

The narrower street

c)

The wider street

d)

Twice the width of both streets

3.

Why is it mandatory to keep a minimum horizontal clearance of 1.2 m from power lines?

a)

To prevent resonance vibration of lines

b)

To reduce corona discharge

c)

To protect residents from accidental contact

d)

To minimize electromagnetic induction on rebars

4.

A mezzanine floor is permitted only if —

a)

It exceeds the main floor area

b)

It is at least 2.2 m below the ceiling

c)

It does not exceed the area of the main room and has ≥2.2 m headroom

d)

It is ventilated by forced mechanical circulation

5.

Which design principle ensures that a toilet opening does not face a dining room and that the kitchen is placed away from wind direction?

a)

Aspect

b)

Grouping

c)

Privacy

d)

Sanitation

6.

TRUE/FALSE

In aspect planning, north–south orientation of long walls reduces heat gain from the sun.

(a)  

7.

TRUE/FALSE

According to NBC, a building may be approved on a site with a filled quarry pit if adequate foundation depth is provided.

(a)  

8.

Assertion (A): Cross ventilation is improved when inlet openings are smaller on the windward side than on the leeward side. Reason (R): Larger outlet area creates suction pressure, increasing air velocity through the room.

a)

Both A and R are true and R is the correct explanation

b)

Both A and R are true but R is not the correct explanation

c)

A is true but R is false

d)

Both A and R are false

9.

In residential planning, circulation area is ideally limited to about (a)   of the total plan area to ensure space economy.

10.

The minimum headroom above a mezzanine floor shall be (a)   , ensuring adequate ventilation and user comfort.

11.

For every 3 m increase in height above 10 m, the yard width shall increase by (a)   till it reaches 16 m total width.

12.

A key plan submitted for permit must show the site’s boundary and landmarks to a scale not less than (a)  

13.

In aspect planning, living rooms are usually placed on the (a)   to receive sunlight during most of the day, aiding thermal comfort.

14.

Match the Following

A. Aspect - 1. Financial control during design

B. Circulation - 2. Access and movement between rooms

C. Economy - 3. Proper grouping of sanitary units

D. Sanitation - 4. Admission of light and air

a)

A → 2, B → 4, C → 1, D → 3

b)

A → 4, B → 1, C → 2, D → 3

c)

A → 4, B → 2, C → 1, D → 3

d)

A → 4, B → 2, C → 3, D → 1

15.

MATCH THE FOLLOWING

A. Placing of wall - 1. Broad windows on windward side

B. Projections - 2. Grass and trees around building

C. Roof - 3. Balconies and verandahs on east/west sides

D. Treatment of ground - 4. Roof with valley gutters and waterproofing


a)

A → 3, B → 1, C → 4, D → 2

b)

A → 1, B → 4, C → 3, D → 2

c)

A → 1, B → 3, C → 4, D → 2

d)

A → 1, B → 3, C → 2, D → 4