Electrical Engineering Quiz

Total questions: 55

Worksheet time: 28mins

Name
Class
Date
1.

If line voltage is 120 V, what is the voltage of each connection?

a)

120 V

b)

208 V

c)

69 V

d)

220 V

2.

Power factor correction can result in which of the following?

a)

Increase in transformer losses

b)

Decrease in transformer capacity

c)

Decrease in losses and increase system capacity

d)

Increase in line losses

3.

Name the power factor correction device most typical when phase shift by a general reactive is to be made.

a)

Synchronous motor

b)

Series reactor

c)

Shunt capacitor

d)

Grid feeder

4.

An alternating current generated through four square phases is fed to the voltage of 400 V/50 Hz. The line to neutral voltage would be:

a)

230 V

b)

400 V

c)

346 V

d)

120 V

5.

Choose the right kVA bank rated for a 500 kW load and 0.8 PF to obtain a 0.95 PF (UPF).

a)

164 kVA

b)

156 kVA

c)

120 kVA

d)

200 kVA

6.

In the context of power, what is a lower power system in practice an actual test for?

a)

Power quality margin.

b)

Power quality voltage.

c)

Power quality people.

d)

Power quality current.

7.

What is S = 1?

a)

S = 1

b)

S = 2

c)

S = 0

d)

S = -1

8.

Which of the following equations describes phase reactive power in an unbalanced three-phase load?

a)

(Iphase) × (Vphase) × cos theta

b)

(Iphase) × (Vphase) × sin theta

c)

(Iline) × (Vline) × sin theta

d)

(Iline) × (Vphase) × cos theta

9.

In a three phase system voltages are separated by:

a)

90°

b)

60°

c)

120°

d)

180°

10.

A resistor has a value of 14 ohms. The current through this resistor is 1.5 Amps. What is the volt drop across the resistor?

a)

14 Volts

b)

21 Volts

c)

1.5 Volts

d)

28 Volts

11.

A wye connected load draws 10A per phase. What is the line current?

a)

5A

b)

7A

c)

10A

d)

17A

12.

Three 35 ohm resistors are connected in delta across a 240 Volt 60 Hz three-phase supply. The line current is:

a)

2.4 Amps

b)

4.8 Amps

c)

11.9 Amps

d)

7.2 Amps

13.

If the phase voltage is 120V, what is the line voltage for a wye connection?

a)

120V

b)

150V

c)

208V

d)

240V

14.

To determine the total true power of a balanced three phase system this equation can be used:

a)

I line × V phase × √3 × pf

b)

I line × V line × √3 × pf

c)

I phase × V phase × pf

d)

I line × V line × pf

15.

When power factor correction capacitors are disconnected from the voltage supply:

a)

They must be immediately reconnected

b)

No special procedures are required

c)

The system must be shut down

d)

Appropriate codes for discharge resistors must be enforced

16.

In an unbalanced three-phase delta connected system, the line voltage is:

a)

the same as the phase voltage

b)

twice the phase voltage

c)

half the phase voltage

d)

three times the phase voltage

17.

When three equal loads are connected in wye and then reconnected in delta, the power of the three loads would be:

a)

2 times greater

b)

1.5 times greater

c)

3 times greater

d)

The same

18.

Power factor correction is used to:

a)

To reduce line loss and increase system capacity.

b)

To increase line loss and decrease system capacity.

c)

To reduce voltage and increase current.

d)

To increase power loss and reduce efficiency.

19.

The ratio between the peak value and the root mean square value (RMS) of a periodic waveform is known as:

a)

Form factor

b)

Crest factor

c)

Power factor

d)

Phase factor

20.

An alternator has a phase voltage of 480V. Determine the line voltage when the windings are connected in delta.

a)

277V

b)

415V

c)

240V

d)

480V

21.

When adding capacitors to a circuit to correct the overall power factor, the capacitors must be connected in:

a)

parallel with the load.

b)

series with the load.

c)

series with the supply.

d)

parallel with the supply.

22.

Adding capacitors to a circuit to correct the overall power factor to unity will cause:

a)

The line current to be reduced.

b)

The line current to be increased.

c)

The voltage to be reduced.

d)

The power factor to decrease.

23.

A three phase motor is connected in wye for starting and then delta for running. The line current when the motor is connected in delta is:

a)

The same as in wye connection

b)

Three times that of the wye connection

c)

Three times less of what it would be in wye connection

d)

Half of the wye connection

24.

A delta-connected alternator has a rated voltage of 240 Volts per phase. The alternator is supplying a load of three 24 ohm resistors connected in wye. Calculate the line voltage.

a)

120 Volts

b)

208 Volts

c)

415 Volts

d)

240 Volts

25.

The purple arrow points to the:

a)

Voltage connection

b)

Neutral connection

c)

Current connection

d)

Ground connection

26.

Adding capacitors to a circuit to correct the overall power factor closer to one will cause the:

a)

Current supplied to the load are increased.

b)

Voltage supplied to the load is increased.

c)

VARS supplied to the load are increased.

d)

VARS supplied to the circuit to be reduced.

27.

Choose the equation that is best suited for a delta connected load that draws a line current of 37A.

a)

37A × √3

b)

37A / √3

c)

37A × 3

d)

37A / 3

28.

An unbalanced wye connected three-phase four-wire system has a line to line voltage of 600 Volts. The line to neutral voltage would be:

a)

600 Volts

b)

208 Volts

c)

347 Volts

d)

120 Volts

29.

Comparing phase power to total power of a three phase wye-connected balanced load:

a)

Phase power is equal to the total power

b)

Phase power is half of the total power

c)

Phase power is double the total power

d)

Phase power is only one third of the total power

30.

In a Wye connected system, the phase voltage is equal to:

a)

VL / 1.732

b)

VL × 1.732

c)

VL / 2

d)

VL

31.

An unbalanced wye connected three-phase four-wire system has a line to line voltage of 480 Volts. The line to neutral voltage would be:

a)

480 Volts

b)

240 Volts

c)

277 Volts

d)

120 Volts

32.

What material is commonly used for the stator core in a three-phase induction motor?

a)

Copper

b)

Aluminum

c)

Laminated silicon steel

d)

Plastic

33.

When would you typically use a delta connection for a motor?

a)

For low voltage requirements

b)

For high torque requirements

c)

For low power factor

d)

For energy saving

34.

How does a rotary phase converter typically generate the third phase?

a)

By using a transformer

b)

By using a rotating motor

c)

By using a capacitor bank

d)

By using a rectifier

35.

The phase sequence in a three-phase induction motor affects which of the following?

a)

The voltage rating of the motor

b)

The direction of motor rotation

c)

The efficiency of the motor

d)

The size of the stator core

36.

An unbalanced wye connected three-phase four-wire system has a line to line voltage of 480 Volts. The line to neutral voltage would be:

a)

208 Volts

b)

240 Volts

c)

277 Volts

d)

480 Volts

37.

A wye connected load draws 10A per phase. What is the line current?

a)

5A

b)

15A

c)

10A

d)

20A

38.

Adding capacitors to a circuit to correct the overall power factor to unity will cause:

a)

The line current to be reduced.

b)

The line current to be increased.

c)

The voltage to be reduced.

d)

The power factor to decrease.

39.

In a Wye connected system, the phase voltage is equal to:

a)

VL / 1.732

b)

VL × 1.732

c)

VL / 2

d)

VL × 2

40.

Comparing phase power to total power of a three phase wye-connected balanced load:

a)

Phase power is equal to the total power

b)

Phase power is half of the total power

c)

Phase power is double the total power

d)

Phase power is only one third of the total power

41.

An unbalanced wye connected three-phase four-wire system has a line to line voltage of 600 Volts. The line to neutral voltage would be:

a)

208 Volts

b)

480 Volts

c)

347 Volts

d)

600 Volts

42.

When adding capacitors to a circuit to correct the overall power factor, the capacitors must be connected in:

a)

parallel with the load.

b)

series with the load.

c)

series with the source.

d)

parallel with the source.

43.

Which of the following equations describes phase reactive power in an unbalanced three-phase load?

a)

I(phase) × V(phase) × sin theta

b)

I(line) × V(line) × sin theta

c)

I(phase) × V(phase) × cos theta

d)

I(line) × V(phase) × sin theta

44.

A delta-connected alternator has a rated voltage of 240 Volts per phase. The alternator is supplying a load of three 24 ohm resistors connected in wye. Calculate the line voltage.

a)

120 Volts

b)

208 Volts

c)

240 Volts

d)

480 Volts

45.

Three 120V single-phase loads are fed from a 120/208V 3-phase panel, they draw different currents. The neutral conductor serves the function of:

a)

Balancing the system

b)

Increasing the voltage

c)

Reducing the current

d)

Providing ground fault protection

46.

Three 35 ohm resistors are connected in delta across a 240 Volt 60 Hz three-phase supply. The line current is:

a)

5.25 Amps

b)

7.62 Amps

c)

11.9 Amps

d)

15.3 Amps

47.

In an unbalanced three-phase delta connected system, the line voltage is:

a)

the same as the phase voltage

b)

1.732 times the phase voltage

c)

half the phase voltage

d)

double the phase voltage

48.

Adding capacitors to a circuit to correct the overall power factor closer to one will cause the:

a)

Current supplied to the circuit to increase.

b)

Voltage supplied to the circuit to be reduced.

c)

Power supplied to the circuit to be increased.

d)

VARS supplied to the circuit to be reduced.

49.

In a three phase system voltages are separated by:

a)

60°

b)

90°

c)

120°

d)

180°

50.

A three phase motor is connected in wye for starting and then delta for running. The line current when the motor is connected in delta is:

a)

The same as that of the wye connection

b)

Three times that of the wye connection

c)

Half that of the wye connection

d)

Three times that of the wye connection

51.

When power factor correction capacitors are disconnected from the voltage supply:

a)

No special precautions are needed

b)

Only licensed electricians may perform the disconnection

c)

The supply voltage must be reduced

d)

Appropriate codes for discharge resistors must be enforced

52.

An alternator has a phase voltage of 480V. Determine the line voltage when the windings are connected in delta?

a)

480V / √3

b)

240V

c)

480V × √3

d)

480V

53.

A resistor has a value of 14 ohms. The current through this resistor is 1.5 Amps. What is the volt drop across the resistor?

a)

10 Volts

b)

21 Volts

c)

28 Volts

d)

14 Volts

54.

Power factor correction is used to

a)

To reduce line loss and increase system capacity.

b)

To increase resistance in the circuit.

c)

To decrease voltage.

d)

To increase current.

55.

If the phase voltage is 120V, what is the line voltage for a wye connection?

a)

100V

b)

150V

c)

208V

d)

120V