Lab 5 EMG Quiz

Total questions: 12

Worksheet time: 6mins

Name
Class
Date
1.

Which signal is routed to A2 on the Arduino?

a)

Raw EMG (pre-rectification)

b)

Analog rectified EMG (precision rectifier output)

c)

Analog EMG envelope (LPF output, biased at REF)

d)

Pressure (MPXV)

2.

When using Analog Devices Signal Chain Designer for the analog envelope stage, which set matches the lab spec?

a)

Differential, second order, inverting, Gain=2 V/V

b)

Single-ended, first order, non-inverting, Bias=REF, Gain=1 V/V

c)

Single-ended, first order, inverting, Bias=0 V, Gain=1 V/V

d)

Differential, first order, non-inverting, Bias=REF, Gain=2 V/V

3.

You must justify your chosen envelope cutoff fc​ (typically 2–10 Hz) with a textbook or peer-reviewed reference.

a)

True

b)

False

4.

All datasets used in processing must be resampled to 100 Hz before further steps.

a)

True

b)

False

5.

To fairly compare analog and digital envelopes, the digital envelope’s fc​ must match the analog LPF’s fc​.

a)

True

b)

False

6.

How many total mouse clicks with ginput are required to mark the five plateau regions in the Force–EMG dataset?

a)

5

b)

8

c)

10

d)

12

7.

What is the recommended way to visually highlight the selected plateau regions in your plot?

a)

islocalmax peaks

b)

xregion translucent vertical bands

c)

spectrogram shading

d)

Vertical axis breaks

8.

For which datasets must you convert pressure counts to kPa using PkPa=Vout÷Vs−0.040.009P_{kPa}=\frac{V_{out}\div V_s-0.04}{0.009}

a)

Dataset 2 (Force–EMG) and Dataset 3 (Fatigue)

b)

Dataset 1 (MVC) only

c)

All datasets (MVC, Force–EMG, Fatigue)

d)

None; keep counts

9.

Which statement about MVC normalization is correct?

a)

Normalize all EMG (analog and digital) by MVC_EnvDigital

b)

Normalize only analog rectified EMG by MVC_EnvAnalog

c)

Normalize analog (rectified & envelope) by MVC_EnvAnalog; normalize digital (rectified & envelope) by MVC_EnvDigital

d)

Do not normalize EMG at all

10.

Time-to-50% MVC is measured as:

a)

Time from squeeze start to the first post-peak crossing of 50% of peak-above-baseline

b)

Time from start of recording to when pressure equals baseline

c)

Time from squeeze start to the global minimum

11.

The force decay rate is computed by fitting a straight line to the pressure signal between peak pressure and the 50% level.

a)

True

b)

False

12.

You should plug in the Arduino UNO immediately to begin testing while you are still laying out circuits in Tinkercad.

a)

True

b)

False