wayground logo

Free Printable Worksheets

Font size

S
M
L
XL
Worksheets

MTL2 Cold Water Learner Outcome 7

Total questions: 21

Worksheet time: 11mins

Name
Class
Date
1.

Why is the maintenance of cold water systems important?

a)

To reduce water pressure

b)

To ensure systems and components give good service throughout their working life

c)

To increase water temperature

d)

To avoid installing new systems

2.

When is cold water system maintenance usually carried out if the supply cannot be interrupted?

a)

During peak working hours

b)

Out-of-normal working hours

c)

Only on weekends

d)

During system installation

3.

Which of the following is NOT listed as a planned maintenance task?

a)

Inspection and cleaning of cisterns

b)

Maintenance of water softeners

c)

Installation of new pipework

d)

Checking flow rates at outlets

4.

What should be consulted when servicing appliances in a cold water system?

a)

Local building regulations

b)

Manufacturer’s instructions

c)

Plumbing trade magazines

d)

Water supply company guidelines

5.

Why should a record of all repairs and maintenance tasks be kept?

a)

To calculate water bills

b)

To provide a record of past problems

c)

To comply with insurance requirements only

d)

To avoid future inspections

6.

What is a key indicator of a concealed pipe leak during visual inspection?

a)

Rust on pipe clips

b)

Damp patches on walls or ceilings

c)

Blue/green stains on taps

d)

Water level in cisterns

7.

Which of the following checks helps identify a faulty Float Operated Valve (FOV)?

a)

Inspecting for blue/green stains

b)

Checking water level for signs above shut-off level

c)

Turning isolation valves off

d)

Looking for damp patches on ceilings

8.

What should be inspected inside a plastic cold water storage cistern during maintenance?

a)

Pipe clips and brackets

b)

Debris on the bottom of the cistern

c)

PTFE tape around the spindle

d)

Gate valve corrosion

9.

What is the first step when dealing with a leaking cistern?

a)

Drain the cistern immediately

b)

Isolate the cold water inlet supply and place a warning notice

c)

Remove and replace the cistern

d)

Check for rust on the cistern

10.

What is a common cause of squealing or humming noises when a tap is opened?

a)

Loose pipe clips

b)

Faulty tap washers

c)

Incorrect pipe size

d)

Water hammer arrester failure

11.

What is the best way to prevent banging noises caused by loose pipework?

a)

Reduce water pressure

b)

Replace all washers

c)

Locate and secure the pipework

d)

Install larger diameter pipes

12.

What device can help reduce water hammer if securing pipework is not possible?

a)

Pressure reducing valve

b)

Water hammer arrester

c)

Float operated valve

d)

Isolation valve

13.

What is the first action when dealing with leakage in internal cold water pipework?

a)

Replace the pipe immediately

b)

Isolate the water and drain down the pipework

c)

Call the water authority

d)

Fit a water hammer arrester

14.

What is the first step when re-washering a BS1010 tap with a rising spindle?

a)

Remove the tap head

b)

Isolate the water supply and relieve pressure

c)

Remove the jumper plate

d)

Check the fibre sealing washer

15.

Why should a plug be placed in the sink during tap repair?

a)

To prevent water splashing

b)

To keep the tap steady

c)

To stop screws and nuts from falling down the waste

d)

To avoid damaging the washer

16.

What should be used to prevent the tap body from spinning when breaking the joint?

a)

Adjustable spanner only

b)

Water pump pliers with a cloth in the jaws

c)

PTFE tape

d)

Tap reseating tool

17.

What type of grease should be used when re-greasing the spindle?

a)

Petroleum grease

b)

Silicon grease

c)

Lithium grease

d)

Graphite grease

18.

What tool is used if the tap seat has grooves or pits?

a)

Adjustable spanner

b)

Tap reseating tool with correct grinding head

c)

Water pump pliers

d)

Packing gland nut

19.

What is the most effective way to prevent problems with ceramic disc taps?

a)


Regularly clean the discs

b)

Replace the head workings with a like-for-like replacement

c)

Use PTFE tape on the spindle

d)

Install a water hammer arrester

20.

What is the usual solution for a faulty service valve?

a)

Replacing the washer

b)

Replacing the entire valve

c)

Tightening the gland nut

d)

Applying PTFE tape

21.

Why is it important to record the temperature of cold water in a maintenance log?

a)

To prevent freezing

b)

For legionella protection

c)

To check insulation quality

d)

To monitor tap wear