Overvoltage in Power Systems Quiz

Total questions: 25

Worksheet time: 13mins

Name
Class
Date
1.

Which of the following is a natural cause of overvoltage in power systems?

a)

Switching of capacitor banks

b)

Lightning

c)

Load variations

d)

Tap-changing operations

2.

Switching surges occur mainly due to ________.

a)

Voltage regulation

b)

Closing and opening of circuit breakers

c)

Temperature variations

d)

Conductor sag

3.

Temporary overvoltages are usually associated with ________.

a)

Insulator pollution

b)

Resonance and ground faults

c)

Load shedding

d)

Harmonics

4.

Lightning overvoltage is characterized by ________.

a)

High magnitude and long duration

b)

Low magnitude and long duration

c)

High magnitude and short duration

d)

Low magnitude and short duration

5.

The term "impulse voltage" refers to a voltage with ________.

a)

Slow rise and slow fall

b)

Fast rise and slow fall

c)

Slow rise and fast fall

d)

Fast rise and fast fall

6.

Corona occurs when ________.

a)

Insulation resistance increases

b)

Voltage drops below threshold

c)

Air surrounding the conductor ionizes

d)

Frequency decreases

7.

One common effect of corona is ________.

a)

Increase in insulation strength

b)

Radio interference

c)

Improved power quality

d)

Reduced line reactance

8.

Power loss due to corona increases with ________.

a)

Decrease in humidity

b)

Increase in conductor diameter

c)

Increase in voltage

d)

Decrease in frequency

9.

Bewley Lattice Diagram is used to analyze ________.

a)

Load flow

b)

Travelling waves

c)

Corona inception

d)

Fault currents

10.

For an open-circuited line termination, the travelling wave is ________.

a)

Fully absorbed

b)

Reflected with same polarity

c)

Reflected with opposite polarity

d)

Completely attenuated

11.

Surge arresters protect the system by ________.

a)

Storing energy

b)

Reducing frequency

c)

Limiting overvoltages

d)

Grounding the neutral point

12.

Metal Oxide Varistor (MOV) is commonly used in ________.

a)

Lightning arresters

b)

Circuit breakers

c)

Grounding systems

d)

Transformers

13.

Corona onset voltage depends mainly on ________.

a)

Type of insulator

b)

Conductor diameter and surface condition

c)

Reactive power

d)

Load current

14.

Switching overvoltages are higher in ________.

a)

Low-voltage distribution systems

b)

Underground cables

c)

EHV/UHV transmission lines

d)

LV control circuits

15.

Temporary overvoltages are dangerous mainly because they ________.

a)

Cause fast insulation breakdown

b)

Last longer

c)

Occur at low frequency

d)

Are highly oscillatory

16.

Lightning strokes to transmission lines are minimized by ________.

a)

Bundled conductors

b)

Shield wires

c)

Spacers

d)

Damping resistors

17.

Which component diverts surge currents safely to earth?

a)

Fuse

b)

Reactor

c)

Earthing system

d)

Coupling capacitor

18.

A direct lightning stroke refers to ________.

a)

Lightning hitting a tree

b)

Lightning striking the ground near a substation

c)

Lightning hitting a phase conductor

d)

Induced voltage due to nearby strike

19.

Travelling waves on a line are described by ________.

a)

Maxwell’s equations

b)

Circuit breaker switching curve

c)

Conductivity profile

d)

Generator regulation

20.

Spark gaps are used in surge protection because they ________.

a)

Block DC

b)

Provide a controlled breakdown path

c)

Reduce load current

d)

Increase insulation level

21.

Corona can be reduced by ________.

a)

Using small-diameter conductors

b)

Using bundled conductors

c)

Increasing line frequency

d)

Reducing conductor spacing

22.

The major effect of switching surges in transformers is ________.

a)

Core saturation

b)

Winding insulation stress

c)

Voltage regulation improvement

d)

Increase in efficiency

23.

Overvoltages due to lightning are minimized using ________ on towers.

a)

Anti-vibration dampers

b)

Ground wires

c)

Interphase spacers

d)

Optical cables

24.

In a Bewley diagram, horizontal lines represent ________.

a)

Resistance

b)

Time intervals

c)

Fault current

d)

Magnetic flux

25.

Which of the following does NOT cause temporary overvoltages?

a)

Resonance

b)

Sudden load rejection

c)

Lightning strike

d)

Ungrounded system faults