Imaging process of CR

Total questions: 17

Worksheet time: 9mins

Name
Class
Date
1.

Which radiography type uses a photostimulable phosphor plate scanned to form a digital image?

a)

Digital radiography with CCD

b)

Digital radiography with flat‑panel

c)

Computed radiography with phosphor plates

d)

Conventional radiography using film cassettes

2.

A department is transitioning from conventional radiography to computed radiography. Which change most directly affects the image receptor workflow?

a)

Replacing screen-film cassette with reusable plate cassette.

b)

Switching to reusable film-screen cassettes

c)

switching to new X-ray machine along with flat panel receptor.

d)

Using stronger X-ray tubes for exposure

3.

Which statement best distinguishes Computed Radiography (CR) from Direct Digital Radiography (DR)?

a)

DR uses cassette plates scanned post-exposure

b)

CR uses a reusable phosphor plate read later

c)

DR requires separate image pre-processing step

d)

CR directly converts x-rays to a display image

4.

In a computed radiography setup shown, which component serves as the image receptor that stores the latent X‑ray image before reading?

a)

Barcode scanner beside the workstation

b)

Monitor and workstation display

c)

Cassette rack or holder unit

d)

Photo‑stimulated phosphor imaging plate

5.

A department is upgrading from screen‑film to computed radiography. Which change best describes equipment continuity during the transition?

a)

Eliminates use of any cassettes entirely

b)

Demands new patient positioning tools

c)

Keeps the same X‑ray machine hardware

d)

Requires replacing all X‑ray generators

6.

Which layer of a CR imaging plate stores the latent image after X‑ray exposure?

a)

Reflective backing layer

b)

Support substrate layer

c)

Photostimulable phosphor layer

d)

Protective overcoat layer

7.

A technologist needs to retrieve the latent image from an exposed CR plate. Which step should be performed next?

a)

Place the plate in a dark room

b)

Scan the plate with a laser reader

c)

Expose the plate to more X-rays

d)

Manually peel off the protective layer

8.

An imaging plate is irradiated by X‑rays. Which sequence best explains latent image formation within the phosphor?

a)

Laser excites binder, electrons discharge instantly

b)

Photons reflect from base, then emit immediately

c)

Electrons remain in valence band, no trapping

d)

Electrons jump to conduction band, then get trapped

9.

Which material composition best describes the photostimulable phosphor layer in a CR imaging plate?

a)

Barium fluorohalide with europium activator

b)

Pure barium sulfate without activator

c)

Calcium tungstate with gadolinium dopant

d)

Aluminum oxides with thallium activator

10.

After X-ray exposure in a CR plate, what process forms the latent image?

a)

Protons stored within the valence band

b)

Eu2+ remaining unchanged in valence

c)

Immediate visible light emission only

d)

Liberated electrons trapped at F-centers

11.

In a computed radiography system, what triggers the stored energy in the photostimulable phosphor of the imaging plate to emit light during readout?

a)

Laser beam scanning across the plate

b)

Electrical current applied to plate electrodes

c)

Thermal heating of the imaging plate surface

d)

High-intensity X-ray pulse from the tube

12.

Which component in a CR reader primarily directs the laser beam back and forth across the imaging plate during fast scan mode?

a)

Light channeling guide to the PMT

b)

Rotating polygon or oscillating mirror

c)

Optical filter increasing the SNR

d)

Analog-to-digital converter output

13.

Which component converts collected visible light from the imaging plate into an electronic signal during CR read out?

a)

Analog-to-digital converter digitizing

b)

Photomultiplier tube converting light

c)

Fiber optic light guide bundle

d)

Rotating polygon mirror scanning laser

14.

In computed radiography, what is the primary purpose of the optical filter during readout of the imaging plate?

a)

Convert blue emission into longer wavelength light

b)

Block blue emission reaching the laser source

c)

Pass blue emission while blocking red stimulation

d)

Amplify red stimulation into the photomultiplier tube

15.

What is the primary function of the photomultiplier tube in a computed radiography system?

a)

To store the latent image

b)

To convert light into an electronic signal

c)

To scan the imaging plate with a laser

d)

To enhance the image quality during readout

16.

Which process occurs immediately after the imaging plate is scanned by the laser in a CR system?

a)

Storage of the image in the computer memory

b)

Recharging of the phosphor layer

c)

Conversion of light to digital signal

d)

Erasure of residual latent image

17.

In computed radiography, what is the role of the protective overcoat layer on the imaging plate?

a)

To improve light emission during readout

b)

To prevent physical damage to the plate

c)

To facilitate the scanning process

d)

To enhance the phosphor's sensitivity