
ASE A7 Heating and AC Practice Exam
Flashcard
•
Other
•
10th Grade - University
•
Practice Problem
•
Easy
Wayground Content
Used 1+ times
FREE Resource
Student preview

40 questions
Show all answers
1.
FLASHCARD QUESTION
Front
A CCOT system has a high high side pressure. Technician A says to suspect the thermostatic expansion valve. Technician B says this system contains an orifice tube. Who is correct?
Back
Technician B only
2.
FLASHCARD QUESTION
Front
Corrosion at point A of the electrical diagram above will result in: Excessive resistance in the splice leading to the high pressure sensor., Voltage drop at the connector of the signal circuit for the high pressure sensor., Excessive resistance in the reference circuit of the high pressure sensor., Voltage drop at the connector of the ground circuit for the high pressure sensor.
Back
Voltage drop at the connector of the signal circuit for the high pressure sensor.
3.
FLASHCARD QUESTION
Front
A vehicle's air conditioning performance is reduced at low speeds and stop lights, but cools at highway speeds. Which of these is MOST likely the cause of this condition? Options: A low refriderant charge., A missing fan shroud., A normal condition., A faulty compressore clutch relay.
Back
A missing fan shroud.
4.
FLASHCARD QUESTION
Front
Two technicians are discussing an inoperative electric blend door in an automatic air conditioning system. Technician A says to inspect the blend door's wiring and connections for an open circuit. Technician B says to troubleshoot this circuit with a test light. Who is correct?
Back
Technician A only
5.
FLASHCARD QUESTION
Front
A squeal is heard only when the compressor clutch first engages. Technician A says this is caused by a loose serpentine belt. Technician B says this is caused by a worn clutch pulley bearing. Who is correct?
Back
Technician A only
6.
FLASHCARD QUESTION
Front
Component A in the electrical diagram above has all of the following characteristics EXCEPT: It is a negative temperature Coeffiicient sensor., It is a thermistor., It is a variable resistor., It is a switch
Back
It is a switch
7.
FLASHCARD QUESTION
Front
A frozen spot is noticed in the center of the condenser. Technician A says a frozen spot on a component or connection indicates a restriction in the system. Technician B says this is caused by a clogged orifice tube. Who is correct?
Back
Technician A only
Access all questions and much more by creating a free account
Create resources
Host any resource
Get auto-graded reports

Continue with Google

Continue with Email

Continue with Classlink

Continue with Clever
or continue with

Microsoft
%20(1).png)
Apple
Others
Already have an account?