1.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

The NEC covers the installation of electrical conductors, equipment, and raceways; signaling and communications conductors, equipment , and raceways; and optical fiber cables and raceways for all of the following EXCEPT:

Floating Buildings

Underground Mines

Carnivals

Private Premises

2.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

For specific items of equipment and materials referred to in the NEC, examinations for safety made under standard conditions shall be performed by whom?

Authority Having Jurisdiction

Contractor

Qualified Electrical Testing Laboratory

National Aeronautical and Space Administration

3.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

All electrical equipment shall be listed and labeled.

True

False

4.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

Listed and labeled equipment shall be installed and used in accordance with any instructions included in the listing or labeling.

True

False

Only if required by the AHJ

Depends on the cost of installation

5.

MULTIPLE SELECT QUESTION

1 min • 1 pt

It is NEVER permissible to intermix conductors of dissimilar metals in a terminal or splicing connector (select all correct answers).

True

False

Only if the device is identified for the purpose and conditions of use.

Prohibited for exterior installations only.

6.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

Unless marked otherwise, termination provisions of equipment for circuits rated 100 amperes or less, or marked for 14 AWG through 1 AWG conductors, shall be used only for what temperature rating?

60 degrees C

75 degrees C

90 degrees C

105 degrees C

7.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

Media Image

While installing a new branch circuit on an existing panel board you notice one of the feeder conductors is marked with orange tape and every other breaker space is open (no circuit breaker is installed). When measuring voltage you get the results pictured. What type of system are you working with?

3-phase, 3-wire, ungrounded delta-connected system

3-phase, 4-wire, wye-connected system

3-phase, 4-wire, delta-connected system

1-phase, 3-wire, delta-connected system

Access all questions and much more by creating a free account

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

Already have an account?

Discover more resources for Professional Development