BS7671: Part 4 - 10 Questions

BS7671: Part 4 - 10 Questions

Professional Development

10 Qs

quiz-placeholder

Similar activities

Fault Tree Analysis AHM

Fault Tree Analysis AHM

Professional Development

10 Qs

Grammarville 2.0: Game 1: Birth of the First Ruling House

Grammarville 2.0: Game 1: Birth of the First Ruling House

Professional Development

10 Qs

AP PACIFIC RING OF FIRE

AP PACIFIC RING OF FIRE

1st Grade - Professional Development

15 Qs

Mindray

Mindray

Professional Development

14 Qs

18th Edition Part 4 Mock 2

18th Edition Part 4 Mock 2

Professional Development

10 Qs

BASICS - REVISITED

BASICS - REVISITED

Professional Development

15 Qs

Skill Area 1 - Programmable Logic Controller

Skill Area 1 - Programmable Logic Controller

Professional Development

15 Qs

Movie Scenes

Movie Scenes

6th Grade - Professional Development

13 Qs

BS7671: Part 4 - 10 Questions

BS7671: Part 4 - 10 Questions

Assessment

Quiz

Other

Professional Development

Hard

Created by

Neil Dartnall

Used 14+ times

FREE Resource

10 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

3 mins • 1 pt

1. A 230 V single phase circuit supplying a pump motor is protected by a 20 A type C circuit breaker to BS EN 60898. The minimum value of fault current to ensure compliance with the thermal and shock requirements is:

a) 20 A

b) 140 A

c) 100 A

d) 200 A

2.

MULTIPLE CHOICE QUESTION

3 mins • 1 pt

2. Given that the fault current on a 16A BS 88 fuse is 60A, the corresponding disconnection time is:

a) 0.5 s

b) 1 s

c) 3 s

d) 10 s

3.

MULTIPLE CHOICE QUESTION

3 mins • 1 pt

3. From the time/current characteristic for a 30A BS 3036 fuse, the approximate current required to operate this device at a time of 5 s is:

a) 30 A

b) 66 A

c) 87 A

d) 180 A

4.

MULTIPLE CHOICE QUESTION

3 mins • 1 pt

4. A 15A protective device to BS3036 when carrying a fault current of 180A has an operating time of:

a) 0.4 s

b) 0.2 s

c) 0.1 s

d) 5 s

5.

MULTIPLE CHOICE QUESTION

3 mins • 1 pt

5. A 30A protective device to BS1361 when carrying a fault current of 200A will operate in:

a) 0.2 s

b) 4 s

c) 0.4 s

d) 5 s

6.

MULTIPLE CHOICE QUESTION

3 mins • 1 pt

6. The symbol used to denote the operating current of the device protecting a circuit against overload is:

a) lb

b) l2

c) ln

d) lz

7.

MULTIPLE CHOICE QUESTION

3 mins • 1 pt

7. A 230 V 30 A radial circuit is protected by a BS 3036 device. If the value of earth loop impedance for the circuit is 2.3Ω, disconnection under Line/earth fault condition will occur in:

a) 2 s

b) 4 s

c) 3 s

d) 5 s

Create a free account and access millions of resources