Pre-floor AS/NZ3500.2 Plumbing

Pre-floor AS/NZ3500.2 Plumbing

Professional Development

8 Qs

quiz-placeholder

Similar activities

Sistema Vs Incendios

Sistema Vs Incendios

Professional Development

11 Qs

UAS PERMESINAN BANTU TVIII

UAS PERMESINAN BANTU TVIII

University - Professional Development

4 Qs

Evaluasi: Memelihara sistem hidroponik

Evaluasi: Memelihara sistem hidroponik

Professional Development

10 Qs

Wet Systems Quiz1

Wet Systems Quiz1

Professional Development

8 Qs

II Year Mech D Sec

II Year Mech D Sec

Professional Development

10 Qs

HSE CREW MEETING 03

HSE CREW MEETING 03

Professional Development

10 Qs

Production -Pre questionaries

Production -Pre questionaries

Professional Development

8 Qs

LEEDv4 - Water Efficiency

LEEDv4 - Water Efficiency

Professional Development

10 Qs

Pre-floor AS/NZ3500.2 Plumbing

Pre-floor AS/NZ3500.2 Plumbing

Assessment

Quiz

Professional Development

Professional Development

Hard

Created by

Ice one

Used 11+ times

FREE Resource

8 questions

Show all answers

1.

MULTIPLE SELECT QUESTION

2 mins • 1 pt

What are the two useful reference documents in the Marley manual

NZBC E1

AS/NZS5601.2:2013

NZBC G13

NZBC G12

AS/NZS 3500.2:2003

2.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

Media Image

What is missing off this picture?

It should have a grate on the gully trap

It doesn't have a hose tap charging it

Nothing, it is correct

The vent pipe isn't allowed to connect here

3.

MULTIPLE SELECT QUESTION

2 mins • 1 pt

Choose two design flexibilities that AS/NZS3500 offers over traditional G13 systems

Floor drains can be used as shower wastes.

External gully traps are maximized.

The number of fixture traps can be increased

The size of terminal vents is reduced.

4.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

What is the riser boss junction used for?

Acts as a spacer before the waste pipes enter the gully dish

For a cleaning access point if the gully gets blocked

The riser boss junction takes the individual fixture waste pipes into the gully riser.

The riser boss junction can only take a maximum of 2 fixture waste pipes into the gully riser.

The riser boss junctions must sit vertically between the floor grate and the gully

trap.

5.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

Apart from a basin, what other fixture must be trapped even if it discharges through a floor waste gully or directly connected to a drain or stack.

WC pan

Bidet

Bath

Water feature fountain

Drinking fountain

6.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

Media Image

What is the name of this general layout

G13 pre-floor slab

Roll over stack system

Ground Floor Drainage

Single stack system

7.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

Can a kitchen sink waste discharge to a FWG

No

Yes, only if it is connected to the main drain

No, not normally but only if it has a vent

8.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

With the AS/NZS3500 system it is possible to site an appliance 12.5 meters from the main drain using:

A fixture trap connected to a FWG will give an additional 2.5m when measured from the wier of the fixture trap

A vent pipe off the FWG

Larger size pipes under the slab and bushing at floor level

A sealed clean out only