ELE290

ELE290

University

15 Qs

quiz-placeholder

Similar activities

Introduction to Energy

Introduction to Energy

University

14 Qs

AETECH QUIZ

AETECH QUIZ

University

20 Qs

THREE PHASE

THREE PHASE

University

10 Qs

INVERTER

INVERTER

University

16 Qs

Fundamentals of Electromagnetic Relays

Fundamentals of Electromagnetic Relays

University

15 Qs

Multistage Amplifiers- Unit 1

Multistage Amplifiers- Unit 1

University

20 Qs

DERN 1233 - Test Your Understanding

DERN 1233 - Test Your Understanding

University

10 Qs

VSC vs CSC

VSC vs CSC

University

10 Qs

ELE290

ELE290

Assessment

Quiz

Education

University

Medium

Used 8+ times

FREE Resource

15 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

In delta connected system,

Line voltage is equal to phase voltage

Line current is equal to phase current

Line voltage and line current is zero

None of the above

2.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

The expression for total power output of a delta connected system in terms of phase voltage and current is given by

√3VpIpcos∅

3VpIpcos∅

1/√ 3VpIpcos∅

1/3 x VpIpcos∅

3.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

For a star connected three phase AC circuit,

Line voltage is equal to phase voltage and line current is square root three times the phase current

Line voltage is square root three times phase voltage and phase current is equal to line current

Line voltage is equal to phase voltage and line current is equal to phase current

None of the above

4.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

In a balanced three-phase system-delta load, if we assume the line voltage is VRY = V∠0⁰ as a reference phasor. Then the voltage VYB is?

V∠0⁰

V∠120⁰

V∠-120⁰

V∠240⁰

5.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

A three phase, balanced delta connected load of (4+j8) Ω is connected across a 400V, 3 – Ø balanced supply. Determine the phase current IR . Assume the phase sequence to be RYB.

44.73∠-63.4⁰A

44.73∠63.4⁰A

25.82∠-63.4⁰A

25.82∠63.4⁰A

6.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

Phase voltages of a star connected alternator are VR = 240∠ O° V, VY = 240∠ -120° V & VB = 240 ∠ + 120° V. What is the phase sequence of the system ?

BRY

RBY

YBR

RYB

7.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

In a certain three-wire Y-connected generator, the phase voltages are 2 kV. The magnitudes of the line voltages are

2000 V

1155 V

6000 V

3464 V