Rule VII-VIII (NBCP) - G1

Rule VII-VIII (NBCP) - G1

University

50 Qs

quiz-placeholder

Similar activities

My RME Reviewer

My RME Reviewer

University

50 Qs

BL M-02 FIRE CODE FLASHCARDS 01

BL M-02 FIRE CODE FLASHCARDS 01

University - Professional Development

50 Qs

Administrasi Pajak

Administrasi Pajak

10th Grade - University

45 Qs

SOAL UAS MATEMATIKA KELAS 7 SMTR 1

SOAL UAS MATEMATIKA KELAS 7 SMTR 1

7th Grade - University

45 Qs

Remote Sensing and GNSS Quiz

Remote Sensing and GNSS Quiz

12th Grade - University

50 Qs

PART 8: MCQ from Number 351 – 400

PART 8: MCQ from Number 351 – 400

University

50 Qs

GEAS 22

GEAS 22

University

50 Qs

RFLIB Reviewer

RFLIB Reviewer

University

50 Qs

Rule VII-VIII (NBCP) - G1

Rule VII-VIII (NBCP) - G1

Assessment

Quiz

Other

University

Medium

Created by

TRIXIA JACINTO

Used 68+ times

FREE Resource

50 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

Ventilation or vent shaft shall have a horizontal cross-sectional of not less than 1.0sq. meter for every meter of height of shaft but in no case shall be the area be less than 1.0sq. meter. No vent shaft shall have at least dimension less than __________ millimeters.

600 mm

300mm

500mm

70mm

2.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

A primary or main natural light and ventilation shaft (vertical) with a clear distance of at least______meters shall be located at the center of the building and shall traverse the entire combined height of the building above and below.

2.0m

3.0m

3.5m

5.0m

3.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

Mountable Curves shall be allowed if the sidewalk width is on each side of RROW is at a minimum of ___ meters wide.

6.0m

3.0m

5.0m

8.0m

4.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

Footings shall be of efficient size and strength o support the load of the dwelling and shall be at least ___ millimeters thick and ___millimeters below the surface of the ground

250mm; 500mm

200mm ; 500mm

350mm ; 550mm

250mm ; 600mm

5.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

The meaning of SARP is ______.

Standard regulation practice

Standard regulatory practice

standard and rule practice

Standard and Recommended Practice.

6.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

Wake Chaplets with a minimum of ______for thirty (30) person and at least _____ for each additional person may be provided.

50.00 sq. meter; 1.60 sq. meter

55.00 sq. meter; 1.60 sq. meter

60.00 sq. meter; 1.60 sq. meter

50.00 sq. meter; 2.60 sq. meter

7.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

PSO + TOSL =

TOSL

TLA

AMBF

PSO