1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Media Image

A passive system-dependent recovery process for small appliances;

still uses a pump to recover refrigerant.

must use a pressure relief device when recovering refrigerant.

captures refrigerant in a non-pressurized container.

can only be performed on a system with an operating compressor.

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Media Image

Before beginning a refrigerant recovery procedure, it is ALWAYS necessary to;

allow the appliance to stabilize at room temperature.

know the type of refrigerant that is in the system.

remove the appliance to an outdoor location.

disconnect the appliance from its power source.

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Media Image

Equipment which is used to recover CFC, HCFC, and HFC refrigerant from small appliances for the purpose of disposal must meet what standard?

Recover 95% or the refrigerant whether or not the compressor is operative.

Recover 80% of the refrigerant with an inoperative compressor and 90% of the refrigerant with an operative compressor.

Recover 90% of the refrigerant with an inoperative compressor and 80% of the refrigerant with an operative compressor.

Recover 75% of the refrigerant within 5 minutes.

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Media Image

How many access valves are needed to recover the refrigerant on a sealed system with an operating compressor that has a completely restricted capillary tube?

Two valves, one on the high and one on the low side of the system.

Only one access valve, on the low side of the system.

Only one access valve, on the high side of the system.

Two valves, one at the inlet to the compressor and one at the outlet of the condenser coil.

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Media Image

If a reclamation facility receives a tank of mixed refrigerant, they may;

refuse to accept the refrigerant or charge extra for processing it.

vent the refrigerant.

resell the refrigerant for reuse in its current state.

agree to separate the refrigerants, by the tracking process.

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Media Image

It is generally recommended that piercing-type valves be used on which of the following tubing materials?

Copper and steel

Aluminum and steel

Steel and brass

Copper and aluminum.

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Media Image

Recovery devices for use with small appliances containing CFCs, HCFCs, and HFCs must meet which of the following requirements?

Recovering 90% of the refrigerant when the compressor is operating or achieving a 4-inch vacuum under the conditions of AHRI 740.

Recovering 80% of the refrigerant when the compressor is operating.

Recovering 95% of the refrigerant when the compressor is operating or achieving a 10-inch vacuum under the conditions of AHRI 740.

Recovering 75% of the refrigerant when the compressor is operating.

Access all questions and much more by creating a free account

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

Already have an account?