1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which of the following always falls under the EPA definition for “major maintenance, service, or repair?”

Replacing an oil filter

Replacing an expansion valve

Replacing a compressor

Replacing an accumulator

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Recovering refrigerant from a system in the vapor phase will minimize the loss of which of the following?

Water

Oil

Refrigerant

Non-Condensable

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

After system servicing, and recharging, why is refrigerant vapor reintroduced to the chiller before refrigerant liquid?

Vapor charging increases pressure slowly, preventing failure of the rupture disk.

Vapor charging is faster than liquid charging.

Liquid charging is more difficult to control than vapor charging

Liquid charged into a deep vacuum will evaporate and may lower the temperature freezing water in the heat exchanger tube bundle.

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

In the event of a large release of CFC, HCFC, or HFC refrigerant in a contained area which of the following is true?

Safety goggles and lined butyl gloves are sufficient

Self-contained breathing apparatus (SCBA) or leaving the area is required

Respiratory protection is not required

Dust masks are sufficient

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A comfort-cooling appliance containing 50 lbs or more of R-22 is found to be leaking beyond the applicable leak rate threshold. Unless granted additional time, how many days do you have to repair the leak and conduct the initial leak verification test?

1 day

10 days

30 days

45 days

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What are refrigeration and air-conditioning compressor heaters used for?

To reduce the amount of refrigerant in the oil.

To prevent refrigerant vaporization.

To reduce the amount of entrained water in the receiver.

To prevent acid pitting.

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is a characteristic of a refrigerant oil that is hygroscopic?

It is a good lubricant

It is crude oil and unrefined

It readily absorbs moisture

It can be left open to ambient air

Access all questions and much more by creating a free account

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

Already have an account?