Search Header Logo

971902 Audi Electronic Diagnosis Quiz 2

Authored by Paul Sanders

Professional Development

Professional Development

Used 2+ times

971902 Audi Electronic Diagnosis Quiz 2
AI

AI Actions

Add similar questions

Adjust reading levels

Convert to real-world scenario

Translate activity

More...

    Content View

    Student View

16 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which data bus system of the 2019 A6, A7 and A8 is capable of operating (properly) in single wire mode?

Powertrain CAN

Convenience CAN

LIN bus

Both the Powertrain CAN and Convenience CAN

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the purpose of the shunt resistor in the J367 Battery Monitoring Control Module?

Measuring battery temperature

Measuring charge and discharge current of the battery

Sending and receiving LIN signals to J533

All of the above

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When talking about a pulse-width modulated signal that has a total period length of 10ms. If there is an on time length of 3ms, what is the duty cycle of the signal?

70%

3%

10%

30%

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is important to know when checking power supply of a control module using measuring value blocks?

The scan-tool sampling rate is too low and the DSO should always be used

Measuring value blocks always show the peak voltage of a control module

Control modules often have several power supplies, which cannot all be tested via MVBs

You cannot read voltage readings in MVBs

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When the temperature increases, the resistance of an NTC (temp. sensor)...

Decreases

Increases

Decreases until the sensor reaches 45 degrees Celsius and then increases

Does not decreases or increases because it works on Hall principals

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

DIN standard terminal 31 can be best described as...

Battery positive

Chassis ground

Load reduction

Switched power

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When looking at the below MVB data string for static current shortfalls. What does the "01" represent?122*2019-03-26-15:13*00.5*01*00000

Number of terminal 15 cycles

Number of total static current shortfalls

Running battery number

Time of static current shortfalls in hours

Access all questions and much more by creating a free account

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

Already have an account?