Requirements for System Types

Requirements for System Types

Professional Development

20 Qs

quiz-placeholder

Similar activities

SBILD Kochi T20

SBILD Kochi T20

Professional Development

20 Qs

BIR RDO 27 Caloocan Transfer Tax on Estate and Donation

BIR RDO 27 Caloocan Transfer Tax on Estate and Donation

University - Professional Development

15 Qs

FRONT OFFICE MIX QUIZ

FRONT OFFICE MIX QUIZ

Professional Development

20 Qs

Chapter 4: ROM/RAM

Chapter 4: ROM/RAM

9th Grade - Professional Development

15 Qs

Renewable Energy - TED-Ed

Renewable Energy - TED-Ed

10th Grade - Professional Development

20 Qs

V20 Performance

V20 Performance

Professional Development

16 Qs

Digital Modulation schemes

Digital Modulation schemes

Professional Development

15 Qs

Quiz TNH Bandung

Quiz TNH Bandung

Professional Development

15 Qs

Requirements for System Types

Requirements for System Types

Assessment

Quiz

Professional Development

Professional Development

Medium

Created by

Michael Zurek

Used 16+ times

FREE Resource

AI

Enhance your content in a minute

Add similar questions
Adjust reading levels
Convert to real-world scenario
Translate activity
More...

20 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 5 pts

The NFPA 13 standard shall provide ______ for the design and installation of automatic fire sprinkler systems and exposure protection sprinkler systems.

the minimum requirements

the maximum requirements

formulaic reciprocity

CAD based drawings

2.

MULTIPLE CHOICE QUESTION

30 sec • 5 pts

The most common type of sprinkler system in use today is ______.

a wet system

a dry system

a preaction system

an antifreeze system

3.

MULTIPLE CHOICE QUESTION

30 sec • 5 pts

A wet pipe system shall be provided with a listed relief valve not less than ___ in size and set to operate at 175 psi or 10 psi in excess of the maximum system pressure.

1/4"

1/2"

3/4"

1"

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The dry pipe valve and supply pipe _____ against freezing and mechanical injury.

should be protected

shall be protected

might need to be protected

should never need protection

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

For dry pipe systems, with the exception of some refrigerated spaces, the air supply shall have a capacity capable of restoring normal air pressure in the system within _____.

60 seconds

10 minutes

30 minutes

60 minutes

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The connection pipe from the air supply to the dry pipe valve shall not be less than _____ in diameter and shall enter the sytem aove the priming water level of the dry pipe valve.

1/4 inch

1/2 inch

3/4 inch

1 inch

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

For deluge systems, the detection devices or systems shall be _____ supervised.

automatically

manually

automatically or manually

hydraulically

Create a free account and access millions of resources

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

By signing up, you agree to our Terms of Service & Privacy Policy

Already have an account?