PEC 1

PEC 1

Professional Development

50 Qs

quiz-placeholder

Similar activities

Understanding and Analysing Trusses

Understanding and Analysing Trusses

Professional Development

46 Qs

GED - MOCK - 4

GED - MOCK - 4

Professional Development

50 Qs

GED - MOCK - 3

GED - MOCK - 3

Professional Development

50 Qs

MMW ( Prelim)

MMW ( Prelim)

Professional Development

45 Qs

Salary Board

Salary Board

11th Grade - Professional Development

55 Qs

try out ppg

try out ppg

Professional Development

50 Qs

Unit 1 Review

Unit 1 Review

10th Grade - Professional Development

45 Qs

MGNF - 44

MGNF - 44

Professional Development

45 Qs

PEC 1

PEC 1

Assessment

Quiz

Mathematics

Professional Development

Practice Problem

Hard

Created by

Lira Ortega

FREE Resource

AI

Enhance your content in a minute

Add similar questions
Adjust reading levels
Convert to real-world scenario
Translate activity
More...

50 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Service overhead conductors to a building or other structure ( such as a pole ) on which a meter of disconnecting means is installed shall be considered as a _______ and installed accordingly.

Temporary service

Service lateral

Service drop

Service point

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Underfloor flat-top raceways over 4 inches but not over 8 inches wide with a minimum of 1 inch spacing between raceways shall be covered with concrete to a depth of not less than ______.

3/4"1'

1"

1 1/2"

2"

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Lighting fixtures located in the same room and not directly associated with a hydro massage bathtub, shall be installed in accordance with the requirements covering the installation of that equipment in ______.

swimming pool area

kitchen

exercise room

bathroom

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The allowable fill for an 1 ¼ inch rigid schedule 40 PVC with more than 2 conductors is ______ sq. inch.

0.794

0.333

0.495

0.581

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Induction coils shall be prevented from inducting circulating currents in surrounding metallic equipment, supports, or structures by ______.

I. isolation

II. Shielding

III. insulation of the current paths

I only

II only

I, II & III

I &II only

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

At least one receptacle shall be located a minimum of 5 feet from and not more than _____feet from the inside wall of a spa or hot tub installed indoors.

6

10

12

20

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

An electronically actuated fuse generally consists of all of the following EXCEPT ______?

a control module that provides current sensing

electronically derived time-current characteristics

an interrupting module that interrupts current when an overcurrent through it

a thermally sensitive part that is heated and severed by passage of overcurrent through it.

Access all questions and much more by creating a free account

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

Already have an account?