PEC 2

PEC 2

University

50 Qs

quiz-placeholder

Similar activities

DENT 1041 Review TEST #2

DENT 1041 Review TEST #2

University

50 Qs

Mcqs on Stock market operations

Mcqs on Stock market operations

University - Professional Development

46 Qs

EVALUACION DIAGNÓSTICA DE R V

EVALUACION DIAGNÓSTICA DE R V

University

47 Qs

Journeyman 10 - Nth

Journeyman 10 - Nth

University

50 Qs

AM Broadcasting

AM Broadcasting

University

46 Qs

End of Term Assessment: Sociology 2020 - 2021 Term 1

End of Term Assessment: Sociology 2020 - 2021 Term 1

12th Grade - University

50 Qs

PART 4: MCQ from Number 151 – 200

PART 4: MCQ from Number 151 – 200

University

50 Qs

Kuiz Tatabahasa-Kata Banyak Makna Bersama Cikgu Mazni

Kuiz Tatabahasa-Kata Banyak Makna Bersama Cikgu Mazni

KG - Professional Development

50 Qs

PEC 2

PEC 2

Assessment

Quiz

Other

University

Hard

Created by

Lira Ortega

Used 3+ times

FREE Resource

50 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Potential transformers, and other switchboard devices with potential coils shall be supplied by a circuit that is protected by standard overcurrent devices rated ____amperes or less.

15

20

25

30

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The grounded conductor of a mineral-insulated, metal-sheathed cable shall be identified at the time of installation by ______ marking at its termination.

distinctive

neutral

solid

identified

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

An overcurrent trip unit of a circuit shall be connected in series with each _____.

ungrounded conductor

grounded conductor

overcurrent device

transformer

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Any motor application shall be considered as ____ unless the nature of the apparatus it drives is such that the motor will not operate continuously with load any condition of use.

short-time duty

continuous duty

varying duty

periodic duty

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Distances from signs, radio and TV antennas, tanks or other nonbuilding or non-bridge structures, clearances, vertical, diagonal and horizontal, shall not be less than _____ feet.

2

3

6

8

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

It is the intent of the Code that _____ wiring or the construction of equipment need not be inspected at the time of installation of the equipment, if the equipment has been listed by a qualified electrical testing laboratory.

factory-installed internal

underground

factory-installed

raceway

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The following pool equipment shall be grounded ____.

I. ground-fault circuit-interrupters

II. transformer enclosures

III. electric equipment located within 5 feet of the inside wall of the pool

III only

II & III only

II only

I, II & III