Search Header Logo

POWER PLANT

Authored by Justene Garachico

Other

University

Used 2+ times

POWER PLANT
AI

AI Actions

Add similar questions

Adjust reading levels

Convert to real-world scenario

Translate activity

More...

    Content View

    Student View

199 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What do you call the protective angle between the Overhead ground wire and the power cable in the Transmission tower

shielding angle

surge angle

clearing angle

arcing angle

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Disconnecting switch is provided for proper protection of electric substations and power plant. What is its main function.

for protection of circuit breaker

for maintenance purpose

to break the system under fault

for complete isolation

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The highest magnitude of fault current will determine the size of _________, while the lowest magnitude will determine the size of_____________.

fuse, relay

circuit breaker, isolator

circuit breaker, relay

relay, circuit breaker

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The PTs of a 220 kV transmission line have ratio of 132.76 kV: 66.375 V and are connected wye-wye. A voltmeter connected line to ground reads 66 V, what is the transmission line voltage?

223.15 kV

220.10 kV

228.63 kV

225.25 kV

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The transfer bus scheme has the following characteristics EXCEPT one. Which one of this?

It allows better continuity of service as compared with the single bus

It allows the disconnection of circuit breakers for maintenance without Interrupting the service

It is more flexible

It is more costly than that of the single bus system

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

It is more costly than that of the single bus system

Even with a circuit breaker failure, a station shutdown will not result.

It gives more flexibility

It reduces the likelihood of extended outages of any circuit due to circuit breaker trouble

It permits breaker maintenance without feeder outage.

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A large electric power distribution system is protected against surges and faults by

high-speed relays detecting the trouble

protective gaps crossing drain cells

protective relays operating without a time delay

radio communication system using flow frequency

Access all questions and much more by creating a free account

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

Already have an account?

Similar Resources on Wayground