POWER PLANT

Quiz
•
Other
•
University
•
Medium
Justene Garachico
Used 2+ times
FREE Resource
199 questions
Show all answers
1.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
What do you call the protective angle between the Overhead ground wire and the power cable in the Transmission tower
shielding angle
surge angle
clearing angle
arcing angle
2.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
Disconnecting switch is provided for proper protection of electric substations and power plant. What is its main function.
for protection of circuit breaker
for maintenance purpose
to break the system under fault
for complete isolation
3.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
The highest magnitude of fault current will determine the size of _________, while the lowest magnitude will determine the size of_____________.
fuse, relay
circuit breaker, isolator
circuit breaker, relay
relay, circuit breaker
4.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
The PTs of a 220 kV transmission line have ratio of 132.76 kV: 66.375 V and are connected wye-wye. A voltmeter connected line to ground reads 66 V, what is the transmission line voltage?
223.15 kV
220.10 kV
228.63 kV
225.25 kV
5.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
The transfer bus scheme has the following characteristics EXCEPT one. Which one of this?
It allows better continuity of service as compared with the single bus
It allows the disconnection of circuit breakers for maintenance without Interrupting the service
It is more flexible
It is more costly than that of the single bus system
6.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
It is more costly than that of the single bus system
Even with a circuit breaker failure, a station shutdown will not result.
It gives more flexibility
It reduces the likelihood of extended outages of any circuit due to circuit breaker trouble
It permits breaker maintenance without feeder outage.
7.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
A large electric power distribution system is protected against surges and faults by
high-speed relays detecting the trouble
protective gaps crossing drain cells
protective relays operating without a time delay
radio communication system using flow frequency
Create a free account and access millions of resources
Similar Resources on Wayground
Popular Resources on Wayground
15 questions
Hersheys' Travels Quiz (AM)

Quiz
•
6th - 8th Grade
20 questions
PBIS-HGMS

Quiz
•
6th - 8th Grade
30 questions
Lufkin Road Middle School Student Handbook & Policies Assessment

Quiz
•
7th Grade
20 questions
Multiplication Facts

Quiz
•
3rd Grade
17 questions
MIXED Factoring Review

Quiz
•
KG - University
10 questions
Laws of Exponents

Quiz
•
9th Grade
10 questions
Characterization

Quiz
•
3rd - 7th Grade
10 questions
Multiply Fractions

Quiz
•
6th Grade