Nokia - Subcontractor-23

Nokia - Subcontractor-23

Professional Development

60 Qs

quiz-placeholder

Similar activities

Health and Safety Plumbing 6035 Level 2

Health and Safety Plumbing 6035 Level 2

Professional Development

57 Qs

Chapter 17 Hair Styling

Chapter 17 Hair Styling

Professional Development

55 Qs

PRINCE 2 - Sample Paper 1 (60Q)

PRINCE 2 - Sample Paper 1 (60Q)

Professional Development

60 Qs

CompTIA Project+ Practice Tests, Chapter #1 questions #1-59

CompTIA Project+ Practice Tests, Chapter #1 questions #1-59

Professional Development

59 Qs

CompTIA Security + : Architecture and Design

CompTIA Security + : Architecture and Design

Professional Development

64 Qs

Client System Block 3 Aug 2019

Client System Block 3 Aug 2019

Professional Development

60 Qs

Introduction to GIS and Projection

Introduction to GIS and Projection

Professional Development

55 Qs

UK Driving Test

UK Driving Test

Professional Development

58 Qs

Nokia - Subcontractor-23

Nokia - Subcontractor-23

Assessment

Quiz

Professional Development

Professional Development

Medium

Created by

bayu nugraha

Used 1+ times

FREE Resource

60 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

You are in optimizing 1 new site and 4G Payload suddenly increase and impact to your CSSR KPI, what will you NOT do immediately?
Check if any promo campaign to up the sales
Check your validity of your measurement if any double counting
Payload Increase is good, so make justification for CSSR KPI
Check if any site surrounding site if shutdown

2.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

Which Global NPO community contains network planning and optimization guidance material grouped per technology or product?
Services Community
Radio community Wiki
NPO Modular Working Items Wiki
NPO Services Wiki

3.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

What statement about Uplink Power control is NOT true
UL power control changes may impact UL RSSI and SINR for PUSCH
UL power control is responsible for setting the power of the PHICH
UE is transparent to the UL power control algorithm
UL power control is important for the correct MSG3 reception

4.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

What is the capacity of one time slot in TRX?
32Kbps
16Kbps
64Kbps
8Kbps

5.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

Iu-B is the interface between
NodeB-NodeB
RNC-SGSN
RNC-RNC
NodeB-RNC

6.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

How to improved DL Throughput, except
Single Tx – MIMO
MIMO 2x2 -> 2x4
MIMO 2x2 à 4x4
MIMO 2x4 à 4x2

7.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

Is it possible to plot throughput with a planning tool capable of only path loss based calculations?
1. No, it is only possible with Monte Carlo simulations
2. Yes, if the tool can calculate path loss and SINR (for static load) and MAPL (from link budget) is available for different throughputs
1 and 3 True
3. No, it is not possible based on only path loss calculations

Create a free account and access millions of resources

Create resources
Host any resource
Get auto-graded reports
or continue with
Microsoft
Apple
Others
By signing up, you agree to our Terms of Service & Privacy Policy
Already have an account?