240v installations

240v installations

Professional Development

10 Qs

quiz-placeholder

Similar activities

Water Mains and Water Supply Systems Quiz

Water Mains and Water Supply Systems Quiz

Professional Development

15 Qs

PTO-TERMINATIONS

PTO-TERMINATIONS

Professional Development

13 Qs

BSBWHS412

BSBWHS412

Professional Development

10 Qs

Installation and maintenance of foul water drains

Installation and maintenance of foul water drains

Professional Development

15 Qs

BSBWHS413  Consultation and Participation

BSBWHS413 Consultation and Participation

Professional Development

9 Qs

RTS - Wednesday

RTS - Wednesday

Professional Development

15 Qs

May All Staff Quiz!

May All Staff Quiz!

Professional Development

12 Qs

DES new quiz

DES new quiz

Professional Development

10 Qs

240v installations

240v installations

Assessment

Quiz

Professional Development

Professional Development

Medium

Created by

Matt Thomo

Used 1+ times

FREE Resource

10 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

45 sec • 1 pt

1.       Which AS?NZ 3000 clause Lists the three ways that wiring systems can be selected and installed so as to minimise the risk of mechanical damage?


Mechanical characteristics of the wiring system.

Location selected.

Provision of additional local or general mechanical.

3.3.2.6

Answer explanation

Rule 3.3.2.6 includes all three points in A,B and C

2.

MULTIPLE CHOICE QUESTION

45 sec • 1 pt

1.       What is the requirement for the separation of above ground low voltage wiring systems from gas and water services?

According to 3.9.8.4 (b)

Maintain a distance of at least 25mm from these services

Maintain a distance of at least 35mm from these services

Maintain a distance of at least 45mm from these services

Maintain a distance of at least 50mm from these services

3.

MULTIPLE CHOICE QUESTION

45 sec • 1 pt

1.       What are the AS/NZS 3000 requirements for wiring installed through the space formed between roofing or wall lining material and its immediate support?

600mm

50mm

Not permitted

100mm

4.

MULTIPLE CHOICE QUESTION

45 sec • 1 pt

Media Image

1.       Provide one example of situation where wiring may have been installed in a prohibited location under roofing or wall lining material.

As per AS 3000 rule 3.9.4.3.1

Between tile batten and roofing tiles

On the top of the roof

inside a wall

under the concrete

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

1.       What are the sealing arrangements where a wiring system has penetrated a fire-rated barrier in a building, such as above a suspended ceiling?

As per AS 3000 rule number : 3.9.9.3

100mm separation

Silicon it up

The opening must be close fitting and at least 50mm from other services.

Opening can be no greater than 500mm² (e.g. 25mm diameter hole)

Fire rating must be reinstated

make sure no one can see it

6.

MULTIPLE CHOICE QUESTION

45 sec • 1 pt

List two considerations that need to be addressed when installing electrical wiring and accessories in heritage listed buildings

Victorian style

Style of accessories,

Protection of finished surfaces (e.g. original brickwork)

old types

make sure it's heritage

7.

MULTIPLE CHOICE QUESTION

45 sec • 1 pt

1.       Which NSW Government department should you contact for advice before conducting work on a Heritage listed building?

NSW Environment and Electrical contractors

NSW Goverment and Heritage

VIC Environment and Heritage

NSW Environment and Heritage

Create a free account and access millions of resources

Create resources
Host any resource
Get auto-graded reports
or continue with
Microsoft
Apple
Others
By signing up, you agree to our Terms of Service & Privacy Policy
Already have an account?