Steps in Calculating the Roof Load

Term Test

Quiz
•
Other
•
University
•
Easy
Abegail Joy España
Used 1+ times
FREE Resource
9 questions
Show all answers
1.
REORDER QUESTION
3 mins • 5 pts
Calculate roof area (A) from architectural plans
Select CLTD Roof for time of interest, typically on an hourly basis
Determine roof construction and overall heat transfer coefficient (U)
Select roof no. from ASHRAE Table 31 or Text table 7-34 which is closest to matching actual roof construction.
Corrections: Values on tables
2.
MATCH QUESTION
3 mins • 10 pts
Match the Following
Internal and External
Internal Load
Outside Ventilation Air
OUTDOOR DESIGN : WEATHER CONDITIONS
Summer 22oC to 26oC DB
Components of cooling Load
Check for PAG-ASA weather conditions for
Indoor Conditions
heat generated by occupants, equipment
Components of Space Heat Gain
3.
DRAW QUESTION
1 min • 2 pts
Which line Indicates the Dry bulb Temperature?
4.
DRAW QUESTION
1 min • 2 pts
Which line represents a Wet bulb Temperature?
5.
DRAW QUESTION
1 min • 2 pts
Which line represents the enthalpy?
6.
DRAW QUESTION
1 min • 2 pts
Which line represents the specific volume?
7.
DRAW QUESTION
1 min • 2 pts
Which line represents the Humidity Ratio?
8.
MATCH QUESTION
15 mins • 20 pts
An air-conditioned room that stands on a well-ventilated basement measures 3 m wide, 3 m high and 6 m length. One of the 3 m walls faces west and contains a double-glazed glass window of size 1.5 m by 1.5 m, mounted flush with the wall with no external shading. There are no heat gains through the walls other than the one facing west. Calculate the sensible, latent and total heat gains on the room, room sensible heat factor from the following information. What is the required cooling capacity?
(a)Inside conditions : 25°C dry bulb, 50 percent RH
(b)Outside conditions : 43 °C dry bulb, 24 °C wet bulb
(c)U-value for wall : 1.78 W/m².K
(d)U-value for roof : 1.316 W/ m².K
(e)U-value for floor : 1.2 W/m2.K
(f)Corrected (CLTD) for wall: 25 °C
(g)Corrected (CLTD) for roof: 30 °C
(h)U-value for glass ; 3.12 W/ m².K
(i)Solar Heat Gain (SHG) of glass ; 300 W/ m²
(j)Internal Shading Coefficient (SC) of glass: 0.86
(k)Occupancy : 4 (90 W sensible heat/person):(40 W latent heat/person)
(l)Lighting load : 33 W/m2 of floor area
(m)Appliance load : 600 W (Sensible) + 300 W(latent)
(n)Infiltration : 0.5 Air Changes per Hour
(o)Barometric pressure : 101 kPa
(p)w_o=0.0107 and w_i=0.00992
710.6W
Sensible Load of Roof
388.8W
Sensible Load of Lighting
160W
Sensible Load of Infiltration
2430.65W
Floor Sensible Load
163W
Latent Load of Occupants
9.
LABELLING QUESTION
3 mins • 10 pts
Identify the following cooling load components
lights
glass conduction
Glass Solar
roof
equipment
exterior wall
floor
people
partition wall
Infiltration
Similar Resources on Quizizz
10 questions
Guess the 'BRAND!'

Quiz
•
University
10 questions
Rockwell Hardness test_Material Testing Lab

Quiz
•
University
10 questions
Safety Practices in Construction

Quiz
•
University
13 questions
Roof Styles Quiz

Quiz
•
10th Grade - University
10 questions
Quiz 1- Process Thermodynamics

Quiz
•
University
10 questions
GPS Group_IERA training (Session 1)

Quiz
•
University
10 questions
Vocabulary C1

Quiz
•
5th Grade - University
12 questions
Materials Intr

Quiz
•
University
Popular Resources on Quizizz
15 questions
Multiplication Facts

Quiz
•
4th Grade
25 questions
SS Combined Advisory Quiz

Quiz
•
6th - 8th Grade
40 questions
Week 4 Student In Class Practice Set

Quiz
•
9th - 12th Grade
40 questions
SOL: ILE DNA Tech, Gen, Evol 2025

Quiz
•
9th - 12th Grade
20 questions
NC Universities (R2H)

Quiz
•
9th - 12th Grade
15 questions
June Review Quiz

Quiz
•
Professional Development
20 questions
Congruent and Similar Triangles

Quiz
•
8th Grade
25 questions
Triangle Inequalities

Quiz
•
10th - 12th Grade