Medical Gas Systems 2021 101-125

Medical Gas Systems 2021 101-125

Professional Development

25 Qs

quiz-placeholder

Similar activities

2018 IPC CH 11-14 Quiz

2018 IPC CH 11-14 Quiz

Professional Development

25 Qs

soal PPPK Pedagogik

soal PPPK Pedagogik

Professional Development

20 Qs

2018 IPC CH 10 Study Quiz

2018 IPC CH 10 Study Quiz

Professional Development

25 Qs

SHOC, Noise & PPE and Fit Test

SHOC, Noise & PPE and Fit Test

Professional Development

24 Qs

2018 IFGC CH 5A

2018 IFGC CH 5A

Professional Development

25 Qs

2018 IPC CH 5 Study Quiz

2018 IPC CH 5 Study Quiz

Professional Development

25 Qs

2018 IFGC CH 3A

2018 IFGC CH 3A

Professional Development

25 Qs

2018 IPC CH 7B Quiz

2018 IPC CH 7B Quiz

Professional Development

25 Qs

Medical Gas Systems 2021 101-125

Medical Gas Systems 2021 101-125

Assessment

Quiz

Other

Professional Development

Medium

Created by

Johnny Thulin

Used 1+ times

FREE Resource

25 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

While brazing medical-gas copper joints, a purge gas shall flow continuously to prevent the formation of copper oxide on the inside surface of the joint. What shall be used as a purge gas?
A. oil-free, dry Nitrogen NF
B. oil-less, dry Nitrogen NF
C. oil-free, dry Argon MD
D. any inert gas

2.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

Pipe labels shall be located at a maximum interval of how many feet?
A. 10 ft
B. 15 ft
C. 20 ft
D. 25 ft

3.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

Audible and visual alarm indicators shall meet which of the following requirements?
A. Testing to determine indicator function should be scheduled periodically and records maintained between testing.
B. The staff should be trained to operate the test button periodically and report malfunctions.
C. Individual indicators shall NOT be less than DN20 size
D. CGA C-7

4.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

Station outlets that operate at pressures other than standard gauge pressure (50-55 psi or 160-185 psi for nitrogen), what is required of the outlet labeling?
A. be covered to limit access
B. be located away from other outlets
C. include the operating pressure along with the name of the gas
D. none of the above

5.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

In compliance with NFPA 70, the new alarm wiring is being run installed underground from the initiating device at the source to a junction box located where the wiring first enters the building. NFPA 99 permits what minimum number of sets of wires to connect the initiating device with the junction box for each signal?
A. 1
B. 2
C. 4
D. 3

6.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

Which of the following filler metals shall be used to braze copper-to-copper joints in medical gas/vacuum distribution piping?
A. BCuP series
B. BAg series
C. BNi series
D. BAu series

7.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

NFPA 99 requires tubing to be cut square using a sharp tubing cutter that shall be free from grease, oil or other lubricants not suitable for oxygen service. What sort of treatment is permitted of the tube ends before brazing?
A. May be reamed
B. May be deburred or rolled smooth
C. May be re-cleaned
D. none of the above