Prestressed Quiz 1b

Quiz
•
Professional Development
•
Professional Development
•
Medium
Piledriverob Piledriverob2375
Used 13+ times
FREE Resource
9 questions
Show all answers
1.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
It is recommended that the support bars for beam tendons are ____ minimum.
#4
#3
#5
1/4 in. pencil rod
Answer explanation
PTI
FIELD FIG. 4-8
2.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
Stressing pockets shall be filled with non-metallic non-shrink grout within _____ after tendon tail cutting .
1 DAY
3 days
1 week
10 days
Answer explanation
PTI FIELD 8.4
PTI SPECS 3.12.2
3.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
The minimum weight of the PT coating on the prestressing strand shall not be less than _____ per 100ft. of .5 inch diameter strand.
2.5 LBS.
2 lbs.
3 lbs.
3.5 lbs.
Answer explanation
PTI
SPECS 2.2.3
4.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
Which of the following statements about A416 7 wire tendons is true?
Low relaxation is the standard type
the outer wires are larger in diameter than the center wire.
stress relieved is the standard type
A416 tendons come in threes grades
Answer explanation
ASTM A416
1.1
5.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
When stressing tendons on a post-tensioned slab the electric extension cord should be....
3- wire, 12 gauge & not over 100 ft.
2 wire, 10 gauge and not over 150 ft.
3 wire, 14 gauge and not less than 100 ft.
3 wire, 12 not less than 150 ft.
Answer explanation
PTI
FIELD 6.3.10 G
6.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
Measured elongation tolerance should be within +- ____ of the calculated elongations.
7 %
5%
3%
2%
Answer explanation
PTI
FIELD 7.2.3
7.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
Hairpins are required at the anchorage zone when there are ___ or more consecutive anchors spaced at 12 inches or less.
6
5
8
10
Answer explanation
PTI
FIELD 4.4.14
8.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
If variations between the calculated and actual elongations consistently exceed the allowable tolerance...
Stressing should cease until the cause is determined
stepping should be completed & elongations submitted to the engineer of record
gauge reading should be adjusted to achieve elongations within tolerance.
special inspector should adjust the elongations on the stressing sheets to be within tolerance
Answer explanation
PTI
FIELD 7.2.3
9.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
The test assembly for static tests shall be less than ____ long between anchorages.
3.5 FEET
2 feet
4 feet
5.5 feet
Answer explanation
PTI
SPECS. 2.5.6
Similar Resources on Wayground
5 questions
HSE Requirement at the Workplace (Finale)

Quiz
•
University - Professi...
10 questions
Foot Bones Quiz

Quiz
•
Professional Development
9 questions
Metal Door Frames

Quiz
•
Professional Development
10 questions
Smart Office Launching

Quiz
•
Professional Development
11 questions
Prestressed Concrete HW 1a

Quiz
•
Professional Development
10 questions
Prestressed Concrete HW 1c

Quiz
•
Professional Development
10 questions
Session 3 test prep 1

Quiz
•
Professional Development
10 questions
Types of electrical installation

Quiz
•
Professional Development
Popular Resources on Wayground
10 questions
Lab Safety Procedures and Guidelines

Interactive video
•
6th - 10th Grade
10 questions
Nouns, nouns, nouns

Quiz
•
3rd Grade
10 questions
9/11 Experience and Reflections

Interactive video
•
10th - 12th Grade
25 questions
Multiplication Facts

Quiz
•
5th Grade
11 questions
All about me

Quiz
•
Professional Development
22 questions
Adding Integers

Quiz
•
6th Grade
15 questions
Subtracting Integers

Quiz
•
7th Grade
9 questions
Tips & Tricks

Lesson
•
6th - 8th Grade