1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Fault diagnosis reveals a serious fault in a domestic installation which could result in serious electric shock if nor rectified. Which one of the following persons should be informed immediately in this situation?

The health and safety executive

The local building control Authority

The owner/occupier of the property

The institute of engineering technology

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Fault diagnosis is being undertaken in a building during non-working hours (when the building is unoccupied). A serious and life-threatening fault is discovered to the wiring of a circuit and rectification of the fault will require major works. Which one of the following actions would be the most appropriate in this situation?

The circuit should remain un-touched until a suitable meeting with the client is arranged

The circuit should be securely isolated until the client can be informed of the risk

The circuit should be stripped out until an agreement to rewire it is made

The section of the building concerned should be cordoned-off and notices posted

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which one of the following is the most likely consequence if a loose neutral connection within a lighting circuit is not rectified?

Increased energy bills

Fire

  Electric shock

Burns

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which one of the following is the reason for applying temporary continuity bonds to pipe work?

They are applied after cutting a section of plastic pipe to minimise the risk of electric shock should the pipe be carrying a residual fault current

They are applied before cutting a section of plastic pipe to minimise the risk of electric shock should the pipe be carrying a residual fault current

They are applied after cutting a section of metallic pipe to minimise the risk of electric shock should the pipe be carrying a residual fault current

They are applied before cutting a section of metallic pipe to minimise the risk of electric shock should the pipe be carrying a residual fault current

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which one of the following tools would be used to cut a copper conductor within a flexible cable to the correct length?

Hacksaw

Jigsaw

Side cutters

Craft knife

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which one of the following types of connection is a commonly used within a joint box used in domestic wiring systems?

Screw

Compression

Crimp

Clamp

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which one of the following tests would use a test voltage of 500 V d.c.?

Continuity of protective conductors

Continuity of ring final circuits

Insulation resistance

Polarity

Access all questions and much more by creating a free account

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

Already have an account?