
fundies chpt 27 musculoskeletal
Authored by Anonymous Anonymous
Science
Professional Development

AI Actions
Add similar questions
Adjust reading levels
Convert to real-world scenario
Translate activity
More...
Content View
Student View
19 questions
Show all answers
1.
MATCH QUESTION
1 min • 1 pt
match these terms
external fixator
breaks in the bone
comminuted fracture
The type of cast that encases the hips and one or both legs
fractures
an injury to a joint that results in damage to muscles and ligaments
spica
wires, pins, tongs, or rods used in skeletal traction
sprain
bone broken into many small pieces
2.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
This type of immobilization device is a firm plastic mold form used to keep a joint or joints from flexing
3.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
The limb is wrapped with an elastic bandage or fitted with Velcro wrap to which the frame is attached■ One or more ropes are attached to the frame where a weight is attached. ex Trapeze bar: Use as a hand grip when moving in bed
skeletal traction
skin traction
4.
MULTIPLE SELECT QUESTION
45 sec • 1 pt
Select all of what nurses will monitor to ensure that no complications occur for traction
weights hang freely and do not rest on the floor
ropes pull in a straight line without crossing
assess for skin breakdown beneath external traction devices
when turning a patient in traction, have another person lift up on teh weights, causeing slack in the ropes while the patient is turned.
ensure that the patient's body is in proper alignment so that the traction pulls correctly
5.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
Why does itching occur beneath a cast
skin sheds outer epidermal cells, but when the cast is in place, the cells that have been shed tend to pile up rather than flake off
6.
MATCH QUESTION
1 min • 1 pt
Match the following
three point gait
able to bear weight on affected limb; moves the first crutch forward then then the opposite foot forward
swing-to gait
same as the swing-to gait except that the patient swings both feet forward beyond the level of the crutches
two-point gait
able to bear weight on affected limb; patient stands on both feet and moves both crutches forward at the same time;
swing-through gait
unable to bear weight on the affected limb; moves both crutches and affected foot forward at the same time without touching down or placing weight on it
four-point
able to bear partial weight on affected limb; moves one foot and opposite crutch forward at same time
7.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
What device is used after a total hip replacement to prevent the patient from crossing their legs over the midline?
wedge shaped abduction pillow
Access all questions and much more by creating a free account
Create resources
Host any resource
Get auto-graded reports

Continue with Google

Continue with Email

Continue with Classlink

Continue with Clever
or continue with

Microsoft
%20(1).png)
Apple
Others
Already have an account?