Gas Installation and Tightness Test Quiz

Gas Installation and Tightness Test Quiz

Professional Development

15 Qs

quiz-placeholder

Similar activities

BP, HEENT, PULM, DEVICES

BP, HEENT, PULM, DEVICES

University - Professional Development

20 Qs

Installation of Gas Pipework

Installation of Gas Pipework

Professional Development

15 Qs

Suhu dan Jenis Termometer

Suhu dan Jenis Termometer

9th Grade - Professional Development

15 Qs

Furnace Wiring

Furnace Wiring

Professional Development

10 Qs

ACS CCN1 Quiz 1

ACS CCN1 Quiz 1

Professional Development

11 Qs

phase4mod8unsafe.

phase4mod8unsafe.

Professional Development

18 Qs

Gas Safety Regulations 1998 Quiz

Gas Safety Regulations 1998 Quiz

Professional Development

16 Qs

Phase4Mod5Pipework

Phase4Mod5Pipework

Professional Development

11 Qs

Gas Installation and Tightness Test Quiz

Gas Installation and Tightness Test Quiz

Assessment

Quiz

Created by

John Flower

Science

Professional Development

11 plays

Hard

15 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What equipment is required for a tightness test?

Wrench

Screwdriver

Manometer

Hammer

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What checks are required for any electronic test equipment?

Calibrated

Unplugged

Rusty

Broken

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Where are the readings taken from on a water manometer?

Side of the tube

Bottom of the meniscus

Middle of the tube

Top of the meniscus

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What pressure do we apply to the manometer when carrying out a let-by test?

15-17 mbar

7-10 mbar

10-12 mbar

5-7 mbar

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

How do we confirm let-by of the ECV on a low pressure installation?

Shake the valve

Disconnect the downstream outlet union and apply leak detection fluid to internal barrel or ball

Blow air into the valve

Apply soap on the valve

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the maximum allowable pressure drop for an existing installation with appliances connected, E6 meter with 28mm pipework?

10mbar

12mbar

8mbar

6mbar

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

If the purge volume is less than 0.02m3, is the purge a lit or unlit purge?

Unlit purge

Depends on the weather

Lit purge

Doesn't matter