
Cold Water Supply Systems L3P1,U5,LO2.1.p2.
Authored by Craig Boothright
Science
Professional Development

AI Actions
Add similar questions
Adjust reading levels
Convert to real-world scenario
Translate activity
More...
Content View
Student View
7 questions
Show all answers
1.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
What is the purpose of the accumulator in a pumped supply with pressure control system?
To sense pressure drop on the system
To control the level of water in the cold water storage cistern
To filter and sterilize the water
To maintain system pressure and store water for use when the pump is not running
2.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
What is the usual operating pressure range for pumped supply with pressure control systems?
3 to 5 bar
5 to 7 bar
7 to 10 bar
1.5 to 3 bar
3.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
What is the purpose of the non-return valve or check valve in the pumped supply with pressure control system?
To control the level of water in the cold water storage cistern
To sense pressure drop on the system
To maintain system pressure and store water for use when the pump is not running
To prevent backflow of water into the accumulator
4.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
What is the purpose of the electrically operated float switch in the pumped supply with level control system?
To control the level of water in the cold water storage cistern
To sense pressure drop on the system
To prevent backflow of water into the accumulator
To maintain system pressure and store water for use when the pump is not running
5.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
What is the effect of turning on a tap in a pumped supply with pressure control system?
The pump is switched on and the cistern requires water
The cistern continues to fill until the water level is high enough to close the float switch
The pump starts and the system pressure is maintained
The pressure forces water out of the accumulator
6.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
What is the effect of turning off a tap in a pumped supply with pressure control system?
The pressure forces water out of the accumulator
The pump continues refilling the accumulator until it is at full pressure and capacity again
The cistern requires water and the pump is switched on
The pump starts and the system pressure is maintained
7.
FILL IN THE BLANKS QUESTION
1 min • 4 pts
Starting at the top and working down the accumulator
S_______ under protective cap.
A__ compresses under pressure.
Bladder is made from S________ rubber.
contents of the blue shaded area _____
(a)
Access all questions and much more by creating a free account
Create resources
Host any resource
Get auto-graded reports

Continue with Google

Continue with Email

Continue with Classlink

Continue with Clever
or continue with

Microsoft
%20(1).png)
Apple
Others
Already have an account?