Cold Water Supply Systems L3P1,U5,LO2.1.p2.

Authored by Craig Boothright

Science

Professional Development

Cold Water Supply Systems L3P1,U5,LO2.1.p2.
AI

AI Actions

Add similar questions

Adjust reading levels

Convert to real-world scenario

Translate activity

More...

    Content View

    Student View

7 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the purpose of the accumulator in a pumped supply with pressure control system?

To sense pressure drop on the system

To control the level of water in the cold water storage cistern

To filter and sterilize the water

To maintain system pressure and store water for use when the pump is not running

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the usual operating pressure range for pumped supply with pressure control systems?

3 to 5 bar

5 to 7 bar

7 to 10 bar

1.5 to 3 bar

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the purpose of the non-return valve or check valve in the pumped supply with pressure control system?

To control the level of water in the cold water storage cistern

To sense pressure drop on the system

To maintain system pressure and store water for use when the pump is not running

To prevent backflow of water into the accumulator

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the purpose of the electrically operated float switch in the pumped supply with level control system?

To control the level of water in the cold water storage cistern

To sense pressure drop on the system

To prevent backflow of water into the accumulator

To maintain system pressure and store water for use when the pump is not running

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the effect of turning on a tap in a pumped supply with pressure control system?

The pump is switched on and the cistern requires water

The cistern continues to fill until the water level is high enough to close the float switch

The pump starts and the system pressure is maintained

The pressure forces water out of the accumulator

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the effect of turning off a tap in a pumped supply with pressure control system?

The pressure forces water out of the accumulator

The pump continues refilling the accumulator until it is at full pressure and capacity again

The cistern requires water and the pump is switched on

The pump starts and the system pressure is maintained

7.

FILL IN THE BLANKS QUESTION

1 min • 4 pts

Media Image

Starting at the top and working down the accumulator

S_______ under protective cap.

A__ compresses under pressure.

Bladder is made from S________ rubber.

contents of the blue shaded area _____

(a)  

Access all questions and much more by creating a free account

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

Already have an account?