1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The required positions of rainwater pipes on a new building can be identified in the

Building Plan with underground drainage systems details

Building Specification with building material specifications

Plumbing Specification with plumbing material specifications

Work Programme showing the different dwellings under construction

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Media Image

Which one of the following is a type of plastic gutter pattern?

Mansard

Half round angle connector

Half channel

Elsan

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The maximum recommended length of a 40 mm waste discharge pipe from a bath connected to a Primary Ventilated Stack System is

3 metres

4 metres

5 metres

6 metres

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which one of the following soil stack components is used to connect a waste discharge pipe to a vertical stack, directly opposite the connection from another sanitary fitting?

Access pipe

Three way boss pipe

Cleaning eye tee

Parallel junction

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A small amount of concrete pathway needs to be broken up in order to connect a newly installed soil pipe to the below ground drainage system. Which one of the following must be consulted before this is carried out?

The local Water Supplier

The customer

The local Building Control Officer

All other trades on the job

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which one of the following tools should be used to make a saddle branch connection to a main UPVC soil stack?

A drill and keyhole saw

A hole saw

A sharpened length of copper tube of the correct size

A heated length of copper tube of the correct size

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which one of the following is a requirement of the Primary Ventilated Stack System of above ground discharge pipework?

A maximum of any four sanitary appliances connected into the main stack.

A ventilating pipe from the lowest sanitary fitting connection.

Branch wastes to be as steep as possible and in any case not less than 20°.

A long radius bend at the foot of the main stack to minimise compression.

Access all questions and much more by creating a free account

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

Already have an account?