Which of the following Simocode type is classified as high performance?
Simocode Pro

Quiz
•
Special Education
•
University
•
Medium
Jati Pralistyo
Used 2+ times
FREE Resource
10 questions
Show all answers
1.
MULTIPLE CHOICE QUESTION
1 min • 1 pt
Simocode Pro C
Simocode Pro S
Simocode Pro V PN GP
Simocode Pro V PN
2.
MULTIPLE CHOICE QUESTION
1 min • 1 pt
Which is the statement below related to Simocode Operator Panel is correct?
Operator panel with display (OPD) can be used only for Simocode type which is classified as high performance
Operator panel with display (OPD) can be used for all of Simocode type
Operator panel without display (OP LED) can be used only for Simocode type which is classified as high performance
Operator panel with display (OPD) can be used only for Simocode Pro V PN
3.
MULTIPLE CHOICE QUESTION
1 min • 1 pt
Which following Simocode type cannot be used for control and protection of Star-Delta motor?
Simocode Pro C
SImocode Pro S
Simocode Pro V PN GP
Simocode Pro V PN
4.
MULTIPLE CHOICE QUESTION
1 min • 1 pt
Which of the following trip classes can be set in Simocode?
A. Class 5
B. Class 10
C. Class 20
D. All of options are correct
5.
MULTIPLE CHOICE QUESTION
1 min • 1 pt
If you need active power measurement and it can be seen on the Operator panel, which is the correct answer to select Simocode type?
Simocode Pro C with current/voltage measuring module and Operator panel with display (OPD).
Simocode Pro S with current/voltage measuring module and Operator panel (OP LED)
Simocode Pro V PN GP with current/voltage measuring module and Operator panel with display (OPD)
Simocode Pro V PN with current/voltage measuring module and Operator panel with display (OPD
6.
MULTIPLE CHOICE QUESTION
1 min • 1 pt
If you need Undervoltage protection, which is the correct answer to select Simocode type?
Simocode Pro C with current/voltage measuring module
Simocode Pro S with current/voltage measuring module
Simocode Pro V PN GP with current/voltage measuring module
Simocode Pro V PN with current/voltage measuring module
7.
MULTIPLE CHOICE QUESTION
1 min • 1 pt
After the "ON" control command is issued, SIMOCODE pro must be able to detect current in the main circuit within the execution time. Otherwise, the fault message "Fault" will be issued. What is it the fault name?
Fault - feedback (FB) ON
Fault - feedback (FB) OFF
Fault - execution ON command
Fault - execution OFF command
Create a free account and access millions of resources
Similar Resources on Quizizz
15 questions
SPECIAL CONTROL VALVES

Quiz
•
University
6 questions
PEEE1 MIDTERM Q1

Quiz
•
University
10 questions
Quiz 3: Protection Against Electric Shock

Quiz
•
12th Grade - Professi...
8 questions
CAT Tool session 1

Quiz
•
University
10 questions
Quiz - 4 การเกิดแผ่นดินไหว

Quiz
•
University
10 questions
Genarator Faults

Quiz
•
University
10 questions
EBW3043 - Technical Analysis

Quiz
•
University
6 questions
DIFFERENTIAL RELAY

Quiz
•
University
Popular Resources on Quizizz
15 questions
Character Analysis

Quiz
•
4th Grade
17 questions
Chapter 12 - Doing the Right Thing

Quiz
•
9th - 12th Grade
10 questions
American Flag

Quiz
•
1st - 2nd Grade
20 questions
Reading Comprehension

Quiz
•
5th Grade
30 questions
Linear Inequalities

Quiz
•
9th - 12th Grade
20 questions
Types of Credit

Quiz
•
9th - 12th Grade
18 questions
Full S.T.E.A.M. Ahead Summer Academy Pre-Test 24-25

Quiz
•
5th Grade
14 questions
Misplaced and Dangling Modifiers

Quiz
•
6th - 8th Grade