30 sec • 1 pt
What is the recommended procedure for applying flux to copper joints before soldering?
Apply the flux within the fitting.
Apply the flux on the outside of the pipe.
Apply the flux on both the outside of the pipe and inside of fitting.
Apply the flux to the outside of the fitting.
2.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
Which of the following situations would not be acceptable for the use of a compression fitting on gas pipework?
Installing a compression elbow under floorboards which are to be replaced and carpeted.
Making final connections within 150mm of a wall mounted combination boiler.
Fitting a compression tee to pipework from the meter which is under the stairs and accessible via a door.
Jointing pipework within a garage at low level.
3.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
Which of the following situations require the use of a temporary continuity bond?
Testing and installation for tightness.
Purging installation pipework.
Fitting a tee into an existing pipe.
Removing a gas appliance from the supply.
4.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
If corrosion protective wrapping is used to cover metallic pipework, how far past the corrosive surface must the protection extend?
25mm.
50mm.
75mm.
100mm.
5.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
When gas pipework passes through a wall, what should it always be sleeved with?
Copper pipe one size bigger than the gas pipe.
Steel pipe one size bigger than the gas pipe.
The same material as the pipe and one size bigger than the gas pipe.
A non-metallic pipe one size bigger than the gas pipe.
6.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
What is the maximum spacing between clips of a 35mm copper gas pipe installed horizontally?
1.5m.
2.0m.
2.5m.
3.0m.
7.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
What is the maximum depth of a notch in a joist?
¼ the depth of the joist.
1/8 the depth of the joist.
1.5 x the diameter of the pipe to be installed.
2 x the diameter of the pipe to be installed.