EES 102 w10d2 quiz

EES 102 w10d2 quiz

Professional Development

11 Qs

quiz-placeholder

Similar activities

Fundamental of Common Rail Diesel Fuel System

Fundamental of Common Rail Diesel Fuel System

University - Professional Development

15 Qs

Fire Extinguisher Safety

Fire Extinguisher Safety

10th Grade - Professional Development

10 Qs

DOH Respiratory Care Management

DOH Respiratory Care Management

Professional Development

10 Qs

CPL PoF Atmosphere Revision

CPL PoF Atmosphere Revision

Professional Development

15 Qs

TOSP-OSCAR History

TOSP-OSCAR History

Professional Development

10 Qs

World English Quiz Page 7

World English Quiz Page 7

Professional Development

14 Qs

DG CAT-8

DG CAT-8

Professional Development

10 Qs

B777 Air Conditioning

B777 Air Conditioning

Professional Development

10 Qs

EES 102 w10d2 quiz

EES 102 w10d2 quiz

Assessment

Quiz

Specialty

Professional Development

Hard

Created by

Alex Brinkley

FREE Resource

11 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Media Image

Using the diagram below of a pilot model water heater, letter "G" represents

P.T Valve

thermocouple

pilot assembly

temperature adjustment

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Media Image

In the pilot assembly displayed below, Letter D is which part?

burner

thermocouple holder

air intake

orifice

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Excessive sooting at the water heater is NOT caused by

improper burner alignment

a blockage in the burner tube

low propane pressure

a leak in the inner tank

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Where is the proper location on a pilot model water heater valve to test the propane pressure?

at the main burner orifice

at the gas control pressure tap

at the pilot tubing

at the gas control pilot adjustment

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

the function of the ECO is to

control pressure

control flame height

protect from overheating

turn switch on

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When bench testing a thermostat from a DSI water heater using a multimeter, the measurement taken at ambient temperature should indicate

120VAC

26 ohms

open contacts

closed contacts

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

An electric water heater does not heat and 120 volts is measured at the element with zero amp draw. The problem is likely

a faulty heating element

low propane pressure

a closed thermostat

a defective ECO