EES 102 w10d2 quiz

EES 102 w10d2 quiz

Professional Development

11 Qs

quiz-placeholder

Similar activities

Post COVID SOP

Post COVID SOP

Professional Development

15 Qs

TS5015FP_C2_Guest Cycle

TS5015FP_C2_Guest Cycle

Professional Development

15 Qs

The Family Challenge

The Family Challenge

Professional Development

10 Qs

Foundation Quiz

Foundation Quiz

Professional Development

10 Qs

Discovery Pixar

Discovery Pixar

Professional Development

10 Qs

Fluorides

Fluorides

Professional Development

10 Qs

Larry Stylinson

Larry Stylinson

KG - Professional Development

10 Qs

Shorthaul Quiz

Shorthaul Quiz

Professional Development

10 Qs

EES 102 w10d2 quiz

EES 102 w10d2 quiz

Assessment

Quiz

Specialty

Professional Development

Hard

Created by

Alex Brinkley

FREE Resource

AI

Enhance your content in a minute

Add similar questions
Adjust reading levels
Convert to real-world scenario
Translate activity
More...

11 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Media Image

Using the diagram below of a pilot model water heater, letter "G" represents

P.T Valve

thermocouple

pilot assembly

temperature adjustment

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Media Image

In the pilot assembly displayed below, Letter D is which part?

burner

thermocouple holder

air intake

orifice

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Excessive sooting at the water heater is NOT caused by

improper burner alignment

a blockage in the burner tube

low propane pressure

a leak in the inner tank

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Where is the proper location on a pilot model water heater valve to test the propane pressure?

at the main burner orifice

at the gas control pressure tap

at the pilot tubing

at the gas control pilot adjustment

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

the function of the ECO is to

control pressure

control flame height

protect from overheating

turn switch on

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When bench testing a thermostat from a DSI water heater using a multimeter, the measurement taken at ambient temperature should indicate

120VAC

26 ohms

open contacts

closed contacts

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

An electric water heater does not heat and 120 volts is measured at the element with zero amp draw. The problem is likely

a faulty heating element

low propane pressure

a closed thermostat

a defective ECO

Create a free account and access millions of resources

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

By signing up, you agree to our Terms of Service & Privacy Policy

Already have an account?