Unit 22 Refrigeration System Quiz

Unit 22 Refrigeration System Quiz

University

14 Qs

quiz-placeholder

Similar activities

Recovery Refrigeran

Recovery Refrigeran

12th Grade - University

10 Qs

POWER PLANT ENGINEERING

POWER PLANT ENGINEERING

University

16 Qs

Refrigeration Cycle

Refrigeration Cycle

University

15 Qs

Air Conditioning Components

Air Conditioning Components

12th Grade - University

15 Qs

RAC quiz_ankit saxena

RAC quiz_ankit saxena

University

16 Qs

Refrigeration Cycle

Refrigeration Cycle

University

15 Qs

COMBINED CYCLE

COMBINED CYCLE

University

10 Qs

PERAWATAN SISTEM AC

PERAWATAN SISTEM AC

12th Grade - University

10 Qs

Unit 22 Refrigeration System Quiz

Unit 22 Refrigeration System Quiz

Assessment

Quiz

Science

University

Hard

NGSS
HS-PS3-4, MS-PS3-3, HS-ETS1-3

+1

Standards-aligned

Created by

Robert Hemmila

Used 6+ times

FREE Resource

14 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The refrigerant in a condenser in a refrigeration system ____.

absorbs heat

rejects heat

changes to a vapor

is under lower pressure than the evaporator

Tags

NGSS.HS-PS3-4

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The condenser in a refrigeration system ____.

desuperheats the vapor from the compressor

condenses the vapor from the compressor

subcools the liquid refrigerant before it leaves the condenser

All of the above.

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A normally operating water-cooled condenser is operating with a 10°F differential between water in and water out. If scale forms on the water tubes and the entering water is 85°F, which of the following is possible?

The outlet water temperature will be lower than expected.

The system head pressure will rise.

The water regulating valve will close.

Both a and b are correct.

Tags

NGSS.HS-PS3-4

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Mineral deposits on the water side of a water-cooled condenser act as a(n) ____.

conductor of heat

insulator

cleaning solution

They have no effect on the operation of the condenser.

Tags

NGSS.HS-PS3-4

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The shell-and-tube condenser is cleaned ____.

with a brush after removing the end caps

only with chemicals

with compressed air

with a vacuum cleaner

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

In a water-cooled condenser, a regulating valve is used to control the ____.

refrigerant flow through the pressure reducing device

refrigerant head pressure

suction pressure

water temperature

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What can be used to maintain the head pressure of a system with a water-cooled condenser?

Fan cycling.

Dampers or louvers.

Water regulating valve.

All of the above.

Tags

NGSS.MS-PS3-3

Create a free account and access millions of resources

Create resources
Host any resource
Get auto-graded reports
or continue with
Microsoft
Apple
Others
By signing up, you agree to our Terms of Service & Privacy Policy
Already have an account?